G 18:current

A live document containing the current set of all concepts defined in OIML publications. Generated from G 18 Complete — every terminology entry observed across the OIML publication corpus.

Vision: When developing a future SMART Recommendation, specification of a term in Part 1 would retrieve the agreed definition from the agreed vocabulary. G 18:current makes this possible by maintaining a live concept registry.
1817
total concepts
1815
with definitions
398
from V 1/V 2
1419
OIML-specific (V 3)

Concept registry

ConceptVocabularyDefinitionPubs
(gross) calorific value—amount of heat which would be released by the complete combustion in air of a specified quantity of gas, in such a way that the pressure at which the reaction takes place remains constant, and all the products of combustion are returned to the same specified temperature as that of the reactants, all of these products being in the gaseous state except for water formed by combustion, which is condensed to the liquid state at this specified temperature1
(instrumental) drift—continuous or incremental change over time in indication, due to changes in the metrological properties of a measuring instrument1
(measurement) error—measured quantity value minus a reference quantity value1
(measurement) standardVIMmaterial measure, measuring instrument, reference material or measuring system intended to define, realize, conserve or reproduce a unit or one or more values of a quantity to serve as a reference1
(permanent) magnetization—parameter that specifies a magnetic state of material bodies such asweights, in the absence of an external magnetic field (most generally, magnetization is a vector whose magnitude and direction are not necessarily constant within the material). The magnetization of a body generates an inhomogeneous magnetic field in space and thus may produce magnetic forces on other materials1
(volume) magnetic susceptibility—measure of the ability of a medium to modify a magnetic field. It isrelated to the magnetic permeability (µ) by the relation: µ / µ0 + c. The quantity µ / µ0 is sometimes referred to as the relative permeability, µr2
<math xmlns="http://www.w3.org/1998/Math/MathML" display="inline"> <mstyle displaystyle="true"> <msub> <mi>T</mi> <mn>1</mn> </msub> </mstyle> </math> error—an inadequate prepackage found to contain an actual quantity less than the nominal quantity minus the tolerable deficiency allowed in 4.2.3 for the nominal quantity is called a <math xmlns="http://www.w3.org/1998/Math/MathML" display="inline"> <mstyle displaystyle="true"> <msub> <mi>T</mi> <mn>1</mn> </msub> </mstyle> </math> error <math xmlns="http://www.w3.org/1998/Math/MathML" display="inline"> <mstyle displaystyle="true"> <msub> <mi>T</mi> <mn>1</mn> </msub> </mstyle> </math> error: <math xmlns="http://www.w3.org/1998/Math/MathML" display="inline"> <mstyle displaystyle="true"> <mtext>actual contents</mtext> <mo>&#x3c;</mo> <mrow> <mo>(</mo> <msub> <mi>Q</mi> <mtext>n</mtext> </msub> <mo>&#x2212;</mo> <mi>T</mi> <mo>)</mo> </mrow> </mstyle> </math> 1
<math xmlns="http://www.w3.org/1998/Math/MathML" display="inline"> <mstyle displaystyle="true"> <msub> <mi>T</mi> <mn>2</mn> </msub> </mstyle> </math> error—an inadequate prepackage found to contain an actual quantity less than the nominal quantity minus twice the tolerable deficiency for a nominal quantity allowed in 4.2.3 is called a <math xmlns="http://www.w3.org/1998/Math/MathML" display="inline"> <mstyle displaystyle="true"> <msub> <mi>T</mi> <mn>2</mn> </msub> </mstyle> </math> error. <math xmlns="http://www.w3.org/1998/Math/MathML" display="inline"> <mstyle displaystyle="true"> <msub> <mi>T</mi> <mn>2</mn> </msub> </mstyle> </math> error: <math xmlns="http://www.w3.org/1998/Math/MathML" display="inline"> <mstyle displaystyle="true"> <mi>a</mi> <mi>c</mi> <mi>t</mi> <mi>u</mi> <mi>a</mi> <mi>l</mi> <mi>c</mi> <mi>o</mi> <mi>n</mi> <mi>t</mi> <mi>e</mi> <mi>n</mi> <mi>t</mi> <mi>s</mi> <mo>&#x3c;</mo> <mrow> <mo>(</mo> <msub> <mi>Q</mi> <mi>n</mi> </msub> <mo>&#x2212;</mo> <msub> <mi>T</mi> <mn>2</mn> </msub> <mo>)</mo> </mrow> </mstyle> </math> 1
ability—ability of a measuring instrument to maintain its performance characteristics over a period of use1
Absolute errorVIMthe result of a measurement minus the (conventional) true value of the measurand (VIM:1993, 3.10)2
Absolute error (of indication)—indicated value of a quantity Yi minus a true value of a quantity1
absolute error of measurement—result of measurement minus the reference value of the measurand9
absorbance—logarithm to base ten of the reciprocal of the transmittance4
absorbed braking power—the absorbed braking power is the mechanical input power of the ergometer at the crankshaft and is measured and displayed by the test equipment2
Absorbed dose—quotient of dē by dm, where dē is the incremental mean energy imparted by ionizing radiation to a quantity of matter of mass dm. The unit for absorbed dose is the gray (Gy), where 1 Gy = 1 J/kg6
Absorbed dose working range—set of values of absorbed dose for which the error of the dosimetry system is intended to lie within specified limits4
Absorbed-dose working range—the set of values of absorbed dose for which the error of the dosimetry system is intended to lie within specified limits2
Absorption—transformation of radiant energy to a different form of energy by [ISO 6286, Table 1, No. 7] interaction with matter.2
acceptable solution—design or principle of a software module or hardware unit, or design or principle of a feature that is considered to comply with a particular requirement. An acceptable solution provides an example of how a particular requirement may be met. It does not prejudice any other solution that also meets the requirement1
acceptanceVIMLacceptance of conformity assessment use of a conformity assessment result provided by another person or body2
acceptance of a measuring instrument—the decision and act of giving legal character to a measuring instrument after its initial verification or of reconfirming or restoring its legal character after a subsequent verification2
AccreditationVIML( procedure by which an authoritative body gives formal recognition that a body or person is competent to carry out specific tasks ISO/IEC Guide 2, 12.11)5
accreditation bodyVIMLautoritative body that performs accreditation (ISO/IEC 17000, 4.7)3
accredited calibration laboratory—laboratory that performs calibration of measuring instruments and that is formally recognized by an accreditation authority and that is competent to carry out the calibration (e.g. competence in accordance with ISO/IEC 17025:2017 [2])1
accredited laboratory—a testing laboratory to which accreditation has been granted2
accuracy—closeness of the agreement between the result of a measurement and a true value of the measurand7
accuracy classVIMclass of measuring instrument that meets certain metrological requirements that are intended to maintain errors within specified limits15
accuracy of a grain moisture calibration calibration accuracy—performance characteristic of a calibration assessed at reference conditions1
accuracy of a grain protein calibration—performance characteristic of a calibration assessed at reference conditions1
accuracy of a measuring instrumentVIMability of a measuring instrument to give responses close to a true value1
accuracy of measurementVIMcloseness of the agreement between the result of a measurement and a true value of the measurand1
across-the road speed meter—speed meter with compensation for cosine error using a measured value of the measurement angle,a configured value of the expected measurement angle or combination of the two1
active energy—active power integrated over time1
active power—rate at which energy is transported1
Actual quantity—actual quantity of product that a prepackage in fact contains as determined by measurements made by legal metrology officials2
actual scale division—- - value expressed in units of mass of: the difference between the values corresponding to two consecutive scale marks, for analog indication; or the difference between two consecutive indicated values, for digital indication2
actual scale interval—- - value, expressed in units of mass of: the difference between the values corresponding to two consecutive scale marks, for analog indication; or the difference between two consecutive indicated values, for digital indication2
actual volume—total volume of water passing through the water meter, disregarding the time taken. This is the measurand2
Additional device—part or device, other than an ancillary device, required to ensure Examples of additional devices: correct measurement or intended to facilitate the measuring operations, or which could in any way affect the measurement11
Additional Test Report—report issued by a Testing Laboratory that includes the results of 1. Additional Test Reports are issued under additional tests and examinations, additional to those in the OIML Recommendation, accepted in the scope of a Declaration of Mutual Confidence (DoMC).2
adjustable water meter—water meter (3.1.1) that is connected to or incorporates an adjustment and/or correction device (3.1.7)1
adjusting rail—movable rail or bar used as the reference axis for spectacles during measurement, which is aligned perpendicularly to the optical axis of the focimeter and parallel to the 0° – 180° axis direction2
adjustmentVIMset of operations carried out on a measuring system so that it (VIM:2007, 3.11) provides prescribed indications corresponding to given values of a quantity to be measured7
adjustment (of a measuring instrument)VIMset of operations carried out on a measuring system so that it provides prescribed indications corresponding to given values of a quantity to be measured2
adjustment device—device incorporated in the meter, that only allows shifting of the error curve generally parallel to itself, with a view to bringing errors within the maximum permissible errors. This device may beeither mechanical or electronic10
Adjustment interval for a calorific value determining device—time interval or number of measurements between two necessary adjustments of a calorific value determining device2
adjustment means—means allowing the adjustment of the gas analytical system by the user3
adjustment of a measuring systemVIMLset of operations carried out on a measuring system so that it provides prescribed indications corresponding to given values of a quantity to be measured (VIM:2007, 3.11)6
Adjustment range—range of weight values close to a set point outside which the weighing results may be subject to excessive relative error2
Adjustment-checking operation—an operation involving all relevant internal elements which verifies that the EBA is suitably adjusted1