| temperature_range | 47% | 46 | |
| power_supply_frequency | 32% | 32 | |
| power_supply_voltage | 31% | 31 | |
| software_identification | 24% | 24 | Version number:01.02.00 with checksum:0x51D2. Version number:01.02.01 with checksum:0xD919., ['Version number:01.02.00 with checksum:0x51D2', 'Version number:01.02.01 with checksum:0xD919', 'Version number:01.03.03 with checksum:0x72A3', 'Version number:01.03.04 with checksum:0xA032', 'Version number:01.04.01 with checksum:0xcd68', 'Version number:01.05.00 with checksum:0xcfda', 'Version number:01.06.00 with checksum:0xad3f'], V50.8 |
| measuring_principle | 18% | 18 | Magnetostrictive, Capacitive, Digital Microwave |
| power_supply_type | 16% | 16 | AC |
| probe_body_material | 12% | 12 | Stainless steel, High-grade steel PIN 1.43.01V2A, Teflon, Aluminum 6063 |
| power_supply_voltage_dc | 8% | 8 | |
| floats | 7% | 7 | Stainless steel or expanded PVC, Stainless steel, NBR or expanded PVC, Stainless steel |
| maximum_measuring_range_level | 7% | 7 | 50, 30 |
| power_supply_voltage_ac_mains_100_240v | 6% | 6 | min=100, max=240, min=85, max=264 |
| power_supply_voltage_ac_mains_65v | 6% | 6 | 65, min=65, max=None, min=65, max=85 |
| power_supply_voltage_dc_mains_24_55v | 6% | 6 | min=24, max=55, min=19.2, max=63.25 |
| data_communication_inputs | 6% | 6 | HART, Manual temperature input, 3xHART for temperature transducers, -HART |
| data_communication_outputs | 6% | 6 | Modbus-BPM-HART-4-20mA analog output, Display, 4-20mA analog output (not for legal metrology), Modbus RS485 serial communication, ['Modbus', 'BPM', 'HART', '4-20mA analog output'] |
| density_displacer_measuring_range | 5% | 5 | |
| software | 4% | 4 | Top Level Software, -, Tank manager |
| length | 4% | 4 | |
| fuel_height_accuracy | 4% | 4 | |
| probe_type | 3% | 3 | XMT, VISY-Stick, 924B |
| probe_temperature_range | 3% | 3 | min=-40, max=70, min=-25, max=55 |
| measured_liquid | 3% | 3 | milk |
| pressure_of_use | 3% | 3 | atmospheric |
| power_supply_voltage_tolerance | 3% | 3 | |
| measuring_range | 3% | 3 | |
| electromagnetic_environment_class | 3% | 3 | E2 Industrial, E2 |
| temperature_displacer_measuring_range | 3% | 3 | min=-5, max=35 |
| display_resolution | 2% | 2 | 0.01, 0.1 |
| floats_material | 2% | 2 | Stainless steel or expanded PVC, Stainless steel |
| probes_type | 2% | 2 | VISY-Stick Advanced, DMP-IS-485(option:1-wire) |
| probe_length | 2% | 2 | 3960, min=None, max=3960 |
| probe_accuracy | 2% | 2 | 1, min=-1, max=1 |
| minimal_range | 2% | 2 | 66 |
| scale_of_display | 2% | 2 | 1 |
| compatible_liquids | 2% | 2 | petroleum, diesel, gasoil, bioethanol blended fuels, biodiesel, aqueous urea solution (Adblue), LPG and chemicals, petroleum, diesel, gasoil, bioethanol blended fuels, biodiesel, aqueous urea solution(Adblue),LPG and chemicals |
| voltage_tolerance | 2% | 2 | |
| humidity_class | 2% | 2 | condensing, up to 100% RH |
| power_supply_voltage_ac_main | 2% | 2 | |
| power_supply_type_dc | 2% | 2 | DC |
| maximum_measuring_range | 2% | 2 | 21 |
| liquid_temperature_range | 2% | 2 | min=-200, max=35 |
| software_checksum | 2% | 2 | 31452 |
| console_type | 1% | 1 | MAGLINK32 |
| probe_temperature | 1% | 1 | min=-25, max=55 |
| console_temperature | 1% | 1 | min=5, max=55 |
| temperature | 1% | 1 | min=-25, max=55 |
| controller_type | 1% | 1 | SiteSentinel model SSIIIC |
| controller_resolution | 1% | 1 | 0.01 |
| controller_temperature_range | 1% | 1 | min=5, max=40 |
| controller_software | 1% | 1 | - |
| probe_sensor_controller_type | 1% | 1 | Smart Module Model SSEM |
| probe_sensor_controller_temperature_range | 1% | 1 | min=5, max=40 |
| site_sentinel_cabinet_dimensions | 1% | 1 | |
| smart_module_cabinet_dimensions | 1% | 1 | |
| console_resolution | 1% | 1 | 0.01 |
| console_temperature_range | 1% | 1 | min=5, max=40 |
| interface_unit_temperature_range | 1% | 1 | min=5, max=40 |
| program_name | 1% | 1 | Mepsan Probe |
| operating_system | 1% | 1 | MS Windows XP |
| float_material | 1% | 1 | Stainless steel or PVC |
| power_communication_unit_type | 1% | 1 | Tank manager |
| probes_body_material | 1% | 1 | Stainless steel |
| measured_liquid_temperature | 1% | 1 | min=3, max=8 |
| measured_liquid_density | 1% | 1 | min=1026, max=1033 |
| indication_step | 1% | 1 | 1 |
| probe_body_material_options | 1% | 1 | Aluminium or stainless tube |
| probe_compatibility | 1% | 1 | Petroleum, diesel, gasoil, bioethanol blended fuels, biodiesel, aqueous urea solution(Adblue), LPG and chemicals |
| probe_max_length | 1% | 1 | 3.66 |
| tube_body_material_options | 1% | 1 | Option of aluminium or stainless for the probe tube body |
| electronics_housing_options | 1% | 1 | Option of metallic or high grade polymer electronics housing |
| maximum_length | 1% | 1 | 3.66 |
| console_types | 1% | 1 | TLS2 series, TLS-IB, TLS-50, TLS-3xx series, TLS-4xx series, TLS4 series |
| probe_body_material_option | 1% | 1 | aluminium or stainless tube |
| maximum_probe_length | 1% | 1 | 3.66 |
| probe_operating_temperature | 1% | 1 | min=-25, max=55 |
| console_ambient_temperature | 1% | 1 | min=0, max=40 |
| console_display_resolution | 1% | 1 | 0.1 |
| console_printer_resolution | 1% | 1 | ≥Display resolution |
| console_pc_remote_resolution | 1% | 1 | 0.1 |
| console_humidity | 1% | 1 | 95 |
| material | 1% | 1 | Stainless steel |
| ambient_temperature | 1% | 1 | min=0, max=50 |
| voltage_range | 1% | 1 | min=195.5, max=253 |
| exterior_protection | 1% | 1 | Aluminium LM25 or Stainless Steel AISI 316 |
| maximum_level_height | 1% | 1 | 22 |
| condensing_humidity | 1% | 1 | True |
| power_supply_voltage_ac_mains_100_240 | 1% | 1 | min=100, max=240 |
| power_supply_frequency_ac_mains_100_240 | 1% | 1 | min=50, max=60 |
| power_supply_voltage_ac_mains_65 | 1% | 1 | 65 |
| power_supply_frequency_ac_mains_65 | 1% | 1 | min=50, max=60 |
| power_supply_voltage_dc_mains_24_55 | 1% | 1 | min=24, max=55 |
| ac_mains_100_240v | 1% | 1 | min=100, max=240 |
| ac_mains_65v | 1% | 1 | min=65, max=None |
| dc_mains_24_55v | 1% | 1 | min=24, max=55 |
| frequency | 1% | 1 | min=50, max=60 |
| power_supply_frequency_ac_main | 1% | 1 | min=50, max=60 |
| power_supply_voltage_ac_alternative | 1% | 1 | 65 |
| power_supply_voltage_dc_main | 1% | 1 | min=24, max=55 |
| software_version_01_02_00 | 1% | 1 | checksum:0x477A |
| software_version_01_02_01 | 1% | 1 | checksum:0xB028 |
| software_version_01_03_03 | 1% | 1 | checksum:0x940B |
| software_version_01_04_01 | 1% | 1 | checksum:0x8cc8 |
| software_version_01_05_00 | 1% | 1 | checksum:0xb810 |
| measurand | 1% | 1 | Liquid level inside a tank |
| extreme_value_temp | 1% | 1 | min=-170, max=230 |
| extreme_value_pressure | 1% | 1 | value varies with antenna type |
| ambient_temperature_low | 1% | 1 | -40 |
| ambient_temperature_high | 1% | 1 | 70 |
| relative_humidity | 1% | 1 | 100 |
| dc_mains_voltage | 1% | 1 | min=24, max=48 |
| ac_mains_voltage | 1% | 1 | min=48, max=240 |
| float_materials | 1% | 1 | NBR, PVDF, nickel plated brass |
| power_supply_voltage_ac_main_alternative | 1% | 1 | min=65, max=None |
| power_supply_voltage_ac_mains | 1% | 1 | min=100, max=240 |
| power_supply_voltage_ac_mains_tolerance | 1% | 1 | min=-15, max=10 |
| power_supply_voltage_dc_mains | 1% | 1 | min=24, max=55 |
| power_supply_voltage_dc_mains_tolerance | 1% | 1 | min=-20, max=15 |
| software_identification_level_gauge | 1% | 1 | V10.9 |
| software_identification_tf_or_mf_displacer | 1% | 1 | V5.2 |
| density_displacer_viscosity_limit | 1% | 1 | 5 |