| power_supply_voltage | 55% | 55 | |
| humidity_class | 46% | 46 | |
| scale_interval | 41% | 41 | |
| minimum_capacity | 37% | 37 | |
| temperature_range | 36% | 36 | |
| maximum_capacity | 35% | 35 | |
| electromagnetic_environment_class | 33% | 33 | E2, E3, E1 |
| destined_to_be_used_as | 28% | 28 | Checkweigher, checkweigher, checkweigher, weight grader, weight/price labeller |
| power_supply_type | 26% | 26 | AC, AC single phase, AC or 24V DC |
| power_supply_frequency | 25% | 25 | |
| number_of_scale_intervals | 25% | 25 | 3000, 6000, 1600 |
| tare | 24% | 24 | |
| climatic_environment_intended_location | 18% | 18 | closed, Closed |
| weighing_ranges | 16% | 16 | Single interval, Single intervalMulti-interval, Single interval, Multi-interval |
| software_identification | 14% | 14 | See below, 2.xx.xx.xxxxx, 1.0.0 |
| electromagnetic_environments | 13% | 13 | E1 and E2, E1 and E2, Non-condensing(closed) |
| maximum_rate_of_operation | 12% | 12 | |
| weighing_range | 10% | 10 | Single interval, Single-interval, multi-range or multi-interval, Single-interval |
| maximum_load_transport_system_speed | 8% | 8 | |
| maximum_speed | 7% | 7 | |
| power_supply | 5% | 5 | 230Vac50/60Hz, 230Va.c.-50Hz, 240Va.c.50Hz |
| environment_classes | 5% | 5 | E2, E1 |
| dynamic_setting | 5% | 5 | |
| maximum_number_of_partial_weighing_ranges | 5% | 5 | 2 |
| weighing_mode | 4% | 4 | Dynamic, Static weighing, Dynamic weighing, Static operation |
| em_environments | 4% | 4 | E1 and E2, E1andE2 |
| display_keyboard_location | 4% | 4 | Control and display unit, Display and control unit, Indicator console in cabin |
| belt_speed | 4% | 4 | |
| mechanical_environment_class | 4% | 4 | Vehicle mounted, M3instrument is incorporated into vehicles, M1 |
| maximum_partial_weighing_ranges | 4% | 4 | 3, 2 |
| max_partial_weighing_ranges | 4% | 4 | 2 |
| software_identification_console | 4% | 4 | Version number1.xxWhere xx is a number between00and99that represents minor versions that contain bug fixesand non-legally relevant changes, Version number1.xx;xx=00...99, 1.xx,2.xx,3.xxor4.xx(xx=00...99) |
| software_identification_ad_board | 4% | 4 | Version number:3.xxWhere xx is a number between22and99that represents minor versions that contain bug fixesand non-legally relevant changes, Version number:3.xx;xx=22...99, 3.xx(ForTPB-3356A/D-board,xx=22...99),or1.xx(ForTPB-3772A/D-board,xx=00...99) |
| number_of_verification_scale_intervals | 3% | 3 | min=None, max=10000, min=None, max=200, min=None, max=3000 |
| accuracy_class | 3% | 3 | IIII, III |
| maximum_time_between_automatic_zero_setting | 3% | 3 | 150, 28 |
| interfaces | 3% | 3 | ['Ethernet', 'USB'], Ethernet, RS232, CAN, RS232, CAN1, CAN2 |
| maximum_preset_tare | 3% | 3 | |
| max_scale_intervals | 3% | 3 | |
| max | 3% | 3 | |
| min | 3% | 3 | |
| max_scale_intervals_single_interval | 3% | 3 | |
| max_scale_intervals_multi_interval | 3% | 3 | |
| verification_interval | 2% | 2 | 1, min=1, max=None |
| number_of_intervals | 2% | 2 | min=None, max=3000, min=None, max=4 |
| maximum_tare_effect | 2% | 2 | -Max for single-interval and multi-range, -Max₁ for multi-interval |
| fractional_factor | 2% | 2 | 0.5, p'i=0.5 |
| minimum_input_voltage_per_vsi | 2% | 2 | 0.4 |
| load_cell_interface | 2% | 2 | 4-wire or 6-wire |
| minimum_input_impedance | 2% | 2 | 43 |
| maximum_input_impedance | 2% | 2 | 1200 |
| mains_power_supply | 2% | 2 | 9-32 VDC - not to be supplied from DC mains. |
| operational_temperature | 2% | 2 | min=-15, max=55 |
| load_cell_emax | 2% | 2 | min=10, max=20 |
| climatic_environment_temperature | 2% | 2 | |
| measuring_range | 2% | 2 | All |
| climatic_environment_non_condensing | 2% | 2 | Non-condensing(closed) |
| max_scale_intervals_n | 2% | 2 | 3000 |
| label_applicator_pneumatic_pressure | 2% | 2 | min=4, max=6 |
| maximum_number_of_scale_intervals_n | 2% | 2 | 2400 |
| single_or_multi_interval | 2% | 2 | Any combination of the above |
| max_verification_scale_intervals | 2% | 2 | 6000, min=100, max=None |
| max_rate_of_operation | 2% | 2 | 36 |
| max_number_of_weighing_ranges | 2% | 2 | 2 |
| maximum_number_of_scale_intervals_single_interval | 2% | 2 | min=None, max=6600, n≤3000divisions |
| software_checksum | 2% | 2 | 0xC76579FF |
| preset_tare | 2% | 2 | T≤-Max |
| maximum_number_of_weighing_ranges | 2% | 2 | 2 |
| mode_of_operation | 1% | 1 | Start-Stop operation or operation in motion |
| category | 1% | 1 | ['Y(a)', 'Y(b)', 'XIII(1)', 'XIII(x ≥ 2)'] |
| number_of_ranges_intervals | 1% | 1 | 2 |
| ratio_between_verification_scale_intervals | 1% | 1 | < 3 |
| tara | 1% | 1 | ≤ 0.5 · Max |
| design | 1% | 1 | Single- or multi-interval instrument |
| lever_work | 1% | 1 | None |
| maximum_minimum_vehicle | 1% | 1 | Max depending on the vehicle Min according to OIML R51-1, No. 2.2.2 n≤300 |
| no_n_of_verification_scale_intervals | 1% | 1 | ≤6000(1000) |
| preset_tare_range | 1% | 1 | min=None, max=100 |
| smallest_verification_scale_interval | 1% | 1 | min=0.002, max=None |
| mode_of_weighing | 1% | 1 | ['static', 'dynamic'] |
| electromagnetic_compatibility | 1% | 1 | E2(OIML D11) |
| extra_warm_up_time_0_4_to_0_8_uv | 1% | 1 | 18 |
| extra_warm_up_time_0_8_uv_or_more | 1% | 1 | 3 |
| maximum_cable_length | 1% | 1 | 1533 |
| climatic_influence_class | 1% | 1 | min=-20, max=60 |
| electromagnetic_influence_class | 1% | 1 | E2 selon OIML D11/2013 |
| scale_division | 1% | 1 | min=200, max=None |
| scale_interval_min_to_125g | 1% | 1 | 0.5 |
| scale_interval_125g_to_max | 1% | 1 | 1 |
| pneumatic_pressure | 1% | 1 | 6 |
| tare_t | 1% | 1 | -450e(single interval)-450e1(multi interval) |
| conveyor_speed | 1% | 1 | 70 m/min for loads up to 6 kg, 60 m/min for greater loads |
| belt_speed_range | 1% | 1 | min=20, max=36 |
| load_cell_model | 1% | 1 | Tedea-Huntleigh type 1041 |
| load_cell_rated_capacity | 1% | 1 | 15 |
| operating_rate_wow | 1% | 1 | 130 |
| operating_rate_non_wow | 1% | 1 | 260 |
| maximum_operating_rate | 1% | 1 | min=None, max=45 |
| maximum_conveyor_speed | 1% | 1 | min=None, max=40.0 |
| semi_automatic_zero_setting_device | 1% | 1 | 4 |
| pressure_transducer_measuring_range | 1% | 1 | min=0, max=350 |
| pressure_transducer_output_signal | 1% | 1 | 4...20mA |
| max_operating_rate | 1% | 1 | min=None, max=65 |
| max_conveyor_speed | 1% | 1 | min=None, max=40 |
| operating_speed | 1% | 1 | 40g to 250g:0.3 to 1.33m/s250g to 1000g:0.3 to 1.2m/s1000g to 3000g:0.3 to 1.0m/s3000g to 6000g:0.3 to 0.8m/s |
| load_cell_manufacturer | 1% | 1 | Flintec |
| load_cell_compatibility_conditions | 1% | 1 | Must have OIML R60 cert, same or better characteristics, same design, no oil damper |
| load_cell_voltage_input_per_scale_interval_min_to_1kg | 1% | 1 | 0.46 |
| load_cell_voltage_input_per_scale_interval_1kg_to_6kg | 1% | 1 | 1.87 |
| sealings | 1% | 1 | Two event counters (Calibration Changes, Configuration Changes), physically sealed |
| alternatives | 1% | 1 | Remote pod configuration, M3310 controller |
| load_cell_rated_output_signal | 1% | 1 | 2 |
| display_location | 1% | 1 | Rear of the vehicle, near operating console |
| max_divisions | 1% | 1 | 3000 |
| max_partial_ranges | 1% | 1 | 2 |
| weighing_speed | 1% | 1 | 30 |
| max_partial_range_time | 1% | 1 | min=None, max=-1 |
| max_weighing_ranges | 1% | 1 | min=30, max=None |
| divisions_per_weighing_range | 1% | 1 | min=None, max=3000 |
| number_of_weighing_ranges | 1% | 1 | 2 |
| tare_capacity | 1% | 1 | -Max |
| maximum_weighing_speed | 1% | 1 | min=370, max=740 |
| min_input_voltage_per_verification_scale_interval | 1% | 1 | 1 |
| min_load_cell_resistance | 1% | 1 | 350 |
| max_load_cell_resistance | 1% | 1 | 1050 |
| fraction_of_max_permissible_error | 1% | 1 | 0.5 |
| maximum_tilt | 1% | 1 | 5 |
| tare_single_interval | 1% | 1 | min=None, max=50 |
| tare_multi_interval | 1% | 1 | Max1 |
| measurement_software_version | 1% | 1 | 1.xx or 2.xx or 3.xx(xx=00...99) |
| ad_board_software_version | 1% | 1 | Version numbers:3.xx(For TPB-3356A/D-board,xx=22...99),or1.xx(For TPB-3772A/D-board,xx=00...99) |
| application | 1% | 1 | Intended to be used as postal scale |
| intended_to_be_used_as | 1% | 1 | Container reachstacker |
| software_identification_terminal | 1% | 1 | xR3where x is multi-digit part number |
| software_identification_midac_plus | 1% | 1 | x_r00where x is multi-digit part number |
| maximum_number_of_scale_intervals_multi_interval | 1% | 1 | n≤3000divisions(per partial weighing range) |
| number_of_verification_scale_intervals_n | 1% | 1 | min=None, max=200 |
| operating_mode | 1% | 1 | Start-stop-operation |
| type | 1% | 1 | ER500-C |
| maximum_number_of_verification_scale_intervals | 1% | 1 | 10000 (class Y(a) and XIII), 1000 (class Y(b) and XIIII) or 3×10000 (class Y(a) and XIII), 3×1000 (class Y(b) and XIIII) |
| extra_warm_up_time_for_0_4_uv_le_e_lt_0_8_uv | 1% | 1 | 18 |
| extra_warm_up_time_for_0_8_uv_le_e | 1% | 1 | 3 |
| maximum_cable_length_between_er500_c_and_junction_box | 1% | 1 | 1533 |
| warm_up_time | 1% | 1 | None |
| supply_frequency | 1% | 1 | min=50, max=60 |
| max_number_of_scale_intervals_single_interval | 1% | 1 | n≤3000 divisions |
| max_number_of_scale_intervals_multi_interval | 1% | 1 | n≤3000 divisions(per partial weighing range) |
| max_number_of_partial_weighing_ranges | 1% | 1 | 2 |
| max_load_transport_system_speed | 1% | 1 | 54 |
| software_identification_version | 1% | 1 | 1.00.379 |
| dynamic_setting_adjustment_range | 1% | 1 | 10 |