OIML R50 (Continuous Totalising Automatic Weighing Instruments) Certificate Schema. The certificate structure lists the top-level fields of the document model. The definitions expand the family's own vocabulary. Where the corpus carries fill statistics, the observed fields table shows how often each characteristic actually appears.

Certificate structure

Every R50 certificate is one object with these top-level fields. A "core" shape is shared across all Recommendation families; the rest are defined by this family's own definitions below.

FieldShapeRequired
certificatecore · Certificateyes
issuing_authoritycore · IssuingAuthorityno
applicantscore · PartyListno
manufacturerscore · PartyListno
certified_typeCertifiedTypeyes
characteristicsCharacteristicsyes
recommendationobjectyes
test_reportscore · TestReportListno
revision_historycore · RevisionHistoryno
model_familycore · ModelFamilyno
componentsarray of core · Componentno
footnotescore · FootnoteListno
matrix_tablesMatrixTableListno
d011_tests_applicablearray of D011TestReferenceno

Observed fields

From 5 digitalized R50 certificates: how often each type-level characteristic appears (fill rate), in how many certificates, and the most common values observed.

FieldFill ratePresent inCommon values
power_supply_voltage80%4
totalisation_scale_interval80%4
maximum_flow_rate80%4
minimum_flow_rate80%4
power_supply_frequency60%350, 50
weigh_length60%3
humidity_class60%3
accuracy_class60%3I
maximum_capacity60%3
temperature_range60%3min=-10, max=40
power_supply_type40%2AC
sigma_min40%2Dependent upon application
operating_speed40%2min=0.4, max=5.0, min=0.5, max=3.5
load_cells_excitation_voltage40%28, 5
minimum_load_cell_impedance40%275, 87.5
maximum_load_cell_impedance40%21100, 1100
minimum_input_voltage_per_verification_scale_interval40%23.13, 2.5
minimum_dead_load_voltage40%2
measuring_range40%26.88, 5
electromagnetic_environment_class40%2E2
load_cell_cable40%24wire and screen, 4-wire and shield
belt_speed40%2min=0.5, max=5.2, min=0.2, max=0.5
qmin_reference20%1Qmax
climatic_environment_condition20%1Non-condensing(closed)
minimum_totalised_load20%13.6t
maximum_pulse_frequency20%11000
power_supply_dc20%124
embedded_software_identification20%1WIM3-7.4-20230824
weigh_length_wl20%116
belt_speed_v20%12
totalisation_scale_interval_d20%110
minimum_totalized_load_sigmin20%124
software_identification20%1Ver 2.3
material20%1Bulk material (the ceramic particles were used for in-situ product tests during type evaluation)
reduction_ratio20%10.5
belt_length20%14

Definitions

The shapes named by the certificate structure above, expanded to their fields.

AccuracyClass

CertifiedType

categorystringrequired
type_designationsarray of stringrequired
module_designationstring or null
descriptionstring or null

Characteristics

type_levelobject
model_levelarray of ModelLevelEntry
config_levelarray of ConfigLevelEntry

ModelLevelEntry

attributestringrequired
unit_symbolstring or null
unit_idstring or null
valuesarray of objectrequired

ConfigLevelEntry

attributestringrequired
axisobjectrequired
unit_symbolstring or null
unit_idstring or null
valuesarray of objectrequired

MatrixTableList

D011TestReference

test_idstringrequired
test_level_indexinteger