Skip to content

← Schemas · R46

The R46 schema

OIML R46 (Active Electrical Energy Meters) Certificate Schema. The certificate structure lists the top-level fields of the document model. The definitions expand the family's own vocabulary. Where the corpus carries fill statistics, the observed fields table shows how often each characteristic actually appears.

Certificate structure

Every R46 certificate is one object with these top-level fields. A "core" shape is shared across all Recommendation families; the rest are defined by this family's own definitions below.

FieldShapeRequired
certificatecore · Certificateyes
issuing_authoritycore · IssuingAuthorityno
applicantscore · PartyListno
manufacturerscore · PartyListno
certified_typeCertifiedTypeyes
characteristicsCharacteristicsyes
recommendationobjectyes
test_reportsarray of TestReportno
revision_historyarray of RevisionEntryno
model_familycore · ModelFamilyno
componentsarray of core · Componentno
footnotescore · FootnoteListno
matrix_tablesarray of MatrixTableno
d011_tests_applicablearray of D011TestReferenceno

Observed fields

From 98 digitalized R46 certificates: how often each type-level characteristic appears (fill rate), in how many certificates, and the most common values observed.

FieldFill ratePresent inCommon values
terminal_arrangement89%87DIN, BS, Direct plug-in Essailec connectors
meter_type88%86static, Static
connection_mode88%863p,4w,3e, 3p,4w,3e3p,3w,2e, 1p,2w,1e
humidity_class87%85H1, H2, H3
direction_of_energy_flow_registers80%78Two-registers,bi-directional, bi-directional, Two-register,bi-directional
power_supply_frequency79%77
protective_class79%772, Category2, Category 2
hardware_version68%67S1, 17-X100-01VS1.1, 2R7
meter_constant68%67
ip_rating_environmental_use68%67IP54/indoor, IP54, IP54/Indoor
maximum_current65%64
minimum_current64%63
starting_current63%62
transitional_current59%58
software_identification59%58Checksum:75DF01DD, 2.9.7., P37422020-08-29CHECKSUM:D766
power_supply_voltage52%51
temperature_range47%46
ip_rating20%20IP54, IP51, IP54/indoor
insulation_protection_class11%11II, Category2
specified_clock_frequencies10%10
indoor_outdoor10%10Indoor, Outdoor
tilt_mounting_position10%10Any position is allowed
register_multiplier9%91, /
hardware_versions9%9Functional PCB:DTSD-SZ5-VD2.3_2019.05.21.PCB,DTSD-SY5-VD2.1_2019.04.30.PCB; Power PCB:DTSD-SD5-VD2.3_2019.05.21; Interface PCB:DTSD-SJ5-VD1.9_2019.03.13.PCB,DTSD-SQ5-VD2.2_2019.05.19.PCB, hv10102_C4V2-HT5023-TR4W, hv10134_B6-HT6033_7136S,hv10141_B6-HT6033_7136S
software_versions8%8Metering MCU:VS-000.9,Checksum:9C65; Main MCU:VS-000.8,Checksum:C39A, Version:V1.9.036Checksum:FE08DA0F,Version:V1.9.036Checksum:413AB80A, Metering MCU:200.32025-02-28,Checksum:1328
lower_specified_temperature7%7-25, -40, -25
upper_specified_temperature7%770, 75, 55
direction_of_energy_flow7%7bi-directional, Two-registers,bi-directional., Two-registers,bi-directional
impulse_voltage6%68
accuracy_class4%4B, C
environmental_use3%3Indoor, outdoor
meter_model2%2DDS26D, E3005-SA
serial_numbers2%21903699011,1903699012,1903699015, 19069001,19069002,19069003,19069004,19069005
communication_interfaces2%21 Optical port, 2 RS485 ports, 1 optical port, 1 RS485 port
nominal_voltage_unom2%23×57.7/100...220/380V,3×57.7/100...277/480V, 3×220/380V,3×65/112...277/480V
nominal_frequency_fnom2%250Hz,60Hz, 50Hz,60Hz
maximum_current_imax2%210, 100
transitional_current_itr2%20.05, 0.5
minimum_current_imin2%20.01, 0.25
starting_current_ist2%20.001, 0.02
reference_current2%25
connection_modes1%1single-phase, two-wire,1 element
energy_flow_direction1%1bi-directional
register1%1two-register
indoor_outdoor_type1%1Indoor
temperature_limit1%1min=-40, max=70
application_no1%1OIMLCN200012
meter_name1%1Single-phase Electronic Energy Meter
connection_mode_details1%1Single phase two wires, one element
alternative_connection_mode1%1No
communication_interface1%11 Optical port,1 RS485 port
application_number1%1OIMLCN200013
meter_manufacturer1%1DZG Metering GmbH
nominal_voltage_min1%1133
nominal_voltage_max1%1400
nominal_voltage_133_2301%13x133V/230V
nominal_voltage_230_4001%13x230V/400V
meter_type_electromechanical_static1%1static
connection_mode_phases_wires_elements1%1Direct-connectedThree phases four wires,three elements
energy_flow_registers1%1Two-registers,bi-directional
ib_reference1%120

Definitions

The shapes named by the certificate structure above, expanded to their fields.

HumidityClass

AccuracyClass

AccuracyClassValue

CurrentType

MeterType

EnergyFlowDirection

Register

InsulationProtectionClass

CertifiedType

categorystringrequired
type_designationsarray of stringrequired
meter_typeMeterType
module_designationstring or null
descriptionstring or null

Characteristics

type_levelTypeLevel
model_levelarray of ModelLevelEntry
config_levelarray of ConfigLevelEntry

TypeLevel

accuracy_classAccuracyClass
current_typeCurrentType
temperature_rangeTemperatureRange
electromagnetic_environment_classEMClass
mechanical_environment_classMechanicalClass
climatic_environment_classClimaticClass
humidity_classHumidityClass
checking_facility_typeCheckingFacilityType
meter_typeMeterType
connection_modecore · StructuredValue
connection_mode_detailscore · StructuredValue
connection_modescore · StructuredValue
connection_mode_phases_wires_elementscore · StructuredValue
alternative_connection_modecore · StructuredValue
energy_flow_directionEnergyFlowDirection
direction_of_energy_flowcore · StructuredValue
direction_of_energy_flow_registerscore · StructuredValue
energy_flow_registerscore · StructuredValue
registerRegister
insulation_protection_classInsulationProtectionClass
protective_classInsulationProtectionClass
indoor_outdoorobject
environmental_usecore · StructuredValue
indoor_outdoor_typecore · StructuredValue
ip_ratingcore · StructuredValue
ip_rating_environmental_usecore · StructuredValue
terminal_arrangementcore · StructuredValue
tilt_mounting_positioncore · StructuredValue
nominal_voltagecore · StructuredValue
power_supply_voltagecore · StructuredValue
nominal_frequencycore · StructuredValue
power_supply_frequencycore · StructuredValue
minimum_currentcore · StructuredValue
transitional_currentcore · StructuredValue
maximum_currentcore · StructuredValue
starting_currentcore · StructuredValue
reference_currentcore · StructuredValue
ib_referencecore · StructuredValue
meter_constantcore · StructuredValue
impulse_voltagecore · StructuredValue
hardware_versioncore · StructuredValue
hardware_versionscore · StructuredValue
software_identificationcore · SoftwareIdentification
software_versionscore · StructuredValue
software_checksumcore · StructuredValue
specified_clock_frequenciescore · StructuredValue
register_multipliercore · StructuredValue
communication_interfacecore · StructuredValue
communication_interfacescore · StructuredValue
ambient_temperature_rangeTemperatureRange
temperature_limitTemperatureRange
lower_specified_temperaturecore · StructuredValue
upper_specified_temperaturecore · StructuredValue
application_numberstring
application_nostring
meter_modelstring
meter_namestring
meter_type_electromechanical_staticMeterType
serial_numbersstring

ModelLevelEntry

attributestringrequired
unit_symbolstring or null
unit_idstring or null
valuesarray of objectrequired

ConfigLevelEntry

attributestringrequired
axisstring or null
unit_symbolstring or null
unit_idstring or null
valuesarray of objectrequired

D011TestReference

test_idstringrequired
test_level_indexinteger
notesstring

TestReport

idstringrequired
datestring or null
pagesinteger or null
roleenum of 5

RevisionEntry

revisionstring or integer or nullrequired
datestring or nullrequired
changesstring or null

MatrixTable

namestringrequired
descriptionstring or null
columnsarray of stringrequired
rowsarray of objectrequired
footnotesarray of string