Skip to content

← Schemas · R137

The R137 schema

OIML R137 (Dynamic Measuring Systems for Gases — Gas Meters) Certificate Schema. The certificate structure lists the top-level fields of the document model. The definitions expand the family's own vocabulary. Where the corpus carries fill statistics, the observed fields table shows how often each characteristic actually appears.

Certificate structure

Every R137 certificate is one object with these top-level fields. A "core" shape is shared across all Recommendation families; the rest are defined by this family's own definitions below.

FieldShapeRequired
certificatecore · Certificateyes
issuing_authoritycore · IssuingAuthorityno
applicantsarray of core · Partyno
manufacturersarray of core · Partyno
certified_typeCertifiedTypeyes
characteristicsCharacteristicsyes
recommendationobjectyes
test_reportscore · TestReportListno
revision_historycore · RevisionHistoryno
model_familycore · ModelFamilyno
componentsarray of core · Componentno
footnotescore · FootnoteListno
matrix_tablesMatrixTableListno
d011_tests_applicablearray of D011TestReferenceno

Observed fields

From 99 digitalized R137 certificates: how often each type-level characteristic appears (fill rate), in how many certificates, and the most common values observed.

FieldFill ratePresent inCommon values
temperature_range64%63
gas_temperature_range62%61
orientation51%50Horizontal, Connection ports vertical, All orientations
accuracy_class49%481.5, 0.5, 1
environmental_classes47%46M1/E2, M1/E1, M2/E2
maximum_pressure46%45
designed_for38%38Condensing humidity, condensing humidity, Non condensing humidity
destined_for_the_measurement_of26%26Gas volume, Gas volume of natural gas, type H or L, Gas volume of natural gas type H
power_supply_voltage26%26
flow_direction17%17Uni-directional(indicated with arrow), Uni-directional, Left to right or right to left
software_identification15%15Not applicable, 711001 – CRC: D457E139, Version number:1.24 Checksum:1869761847
destined_for_measurement_of15%15Gas volume, Gas volume of natural gas, type H or L
mechanical_environment_class10%10M2, M1
electromagnetic_environment_class10%10Not applicable(the meter has no electronics), E1, Not applicable
cyclic_volume6%6
minimum_pressure6%6
intended_for_measurement_of6%6Gaseous, including CO2 and Natural gas, Gas volume (natural gas), Natural gas
maximum_flow_rate5%5
base_pressure3%31.01325, Not applicable
base_temperature3%315, Not applicable
electrical_power3%3Not applicable, Lithium battery, 3.6V
transitional_flow_rate3%30.6, 2.5, min=0.25, max=0.6
minimum_flow_rate3%30.016, 0.04, 0.16
destined_for3%3Gas volume
destined_for_measurement3%3gas volume, Gas volume of natural gas type H and L, Gas volume
designed_for_humidity_conditions3%3Not applicable, Not applicable (the gas meter has no electronics)
tsp2%2Not applicable
indicating_device2%2Type O or C, Electronic
ambient_temperature_range_evcd2%2min=-40, max=55
gas_temperature_range_evcd2%2min=-30, max=80
working_pressure2%2The meter is either programmed with a density and viscosity setting, corresponding to the applied gas at preset pressure or using live pressure value from the optional pressure sensor. When using a preset value, the maximum operating range for pressure p_max/p_min is 6.25 symmetrically divided around the preset pressure., The meter is either programmed with a density and viscosity setting, corresponding to the applied gas at preset pressure or using live pressure value from the optional pressure sensor. When using a preset value, the maximum operating range for pressure pmax/pmin is 6.25 symmetrically divided around the preset pressure.
path_angle2%250, 62.5
path_configuration2%2Q.Sonic max: 6 direct paths and 2 reflection swirl paths. Q.Sonic max6: 6 direct paths, Direct measuring paths in an X-shape: -6-path meters:4+2paths -8-path meters:4+4paths
distance_between_the_connections2%2min=110, max=130
indicating_range2%299999.999, 999999.99
scale_interval2%20.00025
intended_for_the_measurement_of2%2Gas volume
intended_for2%2Gas volume
manufacturer_trade_mark1%1
type1%1GALLUS/CQ3000
overload_flow_qr1%17.2
maximum_pressure_in_use_pmax1%10.5
pulse_weight1%110
counting_scale1%11
unit1%1m³
resolution1%10.2
working_temperature_range_tw1%1min=-10, max=40
storage_temperature1%1min=-30, max=70
connection_threads_size1%1M30x2, G7/8", G1", G1¼", M34x1.5, BS746 1
t_sp1%115
ancillary_devices1%1NB-IoT communication
working_pressure_range1%1min=None, max=0.15
software_checksum1%10x7DE0
distance_between_connections1%1min=110, max=130
maximum_pressure_steel_housing1%1
maximum_pressure_aluminium_housing1%1
maximum_pmax_atmos_xxs1%10.5
maximum_pmax_atmos_hpxxa1%11.5
maximum_qmax1%16
minimum_qmin1%10.016
minimum_qt1%10.2
operating_pressure_range_standard_mounts1%1
operating_pressure_range_isolated_mounts1%1
ambient_temperature_range1%1
software_identification_3414_3415_3416_34171%1
software_identification_3414_3415_3416_3417_34181%1
transducers1%1MHz
ambient_temperature_range_with_evcd1%1min=-40, max=55
gas_temperature_range_with_evcd1%1min=-30, max=80
power_supply_type1%1DC
maximum_working_pressure_pmax1%11.5
overload_flow_rate_qr1%130
lubrication1%1Aeroshell Fluid 10
orientation_non_mpv1%1horizontal, vertical up
orientation_mpv1%1horizontal, vertical up and vertical down(all orientations)
power_supply_voltage_ac1%1min=196, max=240
density_range1%1min=1.4, max=450
minimum_maximum_pressure1%1min=8, max=255
sound_frequency1%1200000
outlet_pipe1%15D
maximum_pressure_atmos_xxs1%10.5
maximum_pressure_atmos_hp_xxa1%11.5
software_identification_metrology_version1%1V40.33
software_identification_metrology_checksum1%16F5697AE
software_identification_application_version1%1V16.00.01.50
software_identification_application_checksum1%1DB9A08AA
intended_for_measurement1%1Natural gas types H,L and E,with a Gross Wobbe Index between 39,1MJ/m3and 54,7MJ/m3at15℃and1,01325 bar,including mixtures with a hydrogen concentration of up to 23% by volume.
communication_module1%1G GPRSNB-IoTLoRaWANSF Sigfox

Definitions

The shapes named by the certificate structure above, expanded to their fields.

AccuracyClass

AccuracyClassToken

MeterTechnology

PressureReference

PressureValue

CertifiedType

categorystring or nullrequired
type_designationsarray of stringrequired
meter_technologyMeterTechnology
module_designationobject
descriptionstring or null

Characteristics

type_levelTypeLevel
model_levelarray of ModelLevelEntry
config_levelarray of ConfigLevelEntry

TypeLevel

accuracy_classAccuracyClass
meter_technologyMeterTechnology
temperature_rangeTemperatureRange
gas_temperature_rangeTemperatureRange
ambient_temperature_rangeTemperatureRange
working_temperature_range_twTemperatureRange
storage_temperatureTemperatureRange
environmental_classesEnvironmentalClasses
climatic_environment_classNullableClimaticClass
electromagnetic_environment_classNullableEMClass
mechanical_environment_classNullableMechanicalClass
maximum_pressurePressureValue
minimum_pressurePressureValue
maximum_working_pressure_pmaxPressureValue
working_pressurePressureValue
working_pressure_rangePressureValue
operating_pressure_range_standard_mountsPressureValue
operating_pressure_range_isolated_mountsPressureValue
base_pressurePressureValue
maximum_flow_ratecore · StructuredValue
minimum_flow_ratecore · StructuredValue
transitional_flow_ratecore · StructuredValue
overload_flow_rate_qrcore · StructuredValue
cyclic_volumecore · StructuredValue
indicating_rangecore · StructuredValue
scale_intervalcore · StructuredValue
counting_scalecore · StructuredValue
resolutioncore · StructuredValue
connection_threads_sizecore · StructuredValue
distance_between_connectionscore · StructuredValue
orientationcore · StructuredValue
flow_directioncore · StructuredValue
pulse_weightcore · StructuredValue
density_rangecore · StructuredValue
path_anglecore · StructuredValue
path_configurationcore · StructuredValue
transducerscore · StructuredValue
power_supply_voltagecore · StructuredValue
power_supply_frequencycore · StructuredValue
power_supply_typecore · StructuredValue
power_supply_batterycore · StructuredValue
electrical_powercore · StructuredValue
software_identificationcore · SoftwareIdentification
designed_forcore · StructuredValue
designed_for_humidity_conditionscore · StructuredValue
destined_forcore · StructuredValue
destined_for_measurement_ofcore · StructuredValue
ancillary_devicescore · StructuredValue
lubricationcore · StructuredValue
indicating_devicecore · StructuredValue

EnvironmentalClasses

valueobject
unit_symbolstring or null
unit_idstring or null
footnote_markersarray of string

NullableClimaticClass

valuestring or null
unit_symbolstring or null
unit_idstring or null
footnote_markersarray of string

NullableEMClass

valuestring or null
unit_symbolstring or null
unit_idstring or null
footnote_markersarray of string

NullableMechanicalClass

valuestring or null
unit_symbolstring or null
unit_idstring or null
footnote_markersarray of string

ModelLevelEntry

attributestringrequired
unit_symbolstring or null
valuesarray of objectrequired

ConfigLevelEntry

attributestringrequired
axisstring or null
unit_symbolstring or null
valuesarray of objectrequired

MatrixTable

namestringrequired
descriptionstring or null
columnsarray of stringrequired
column_unitsarray or null
rowsarray of objectrequired
footnotescore · FootnoteList

MatrixTableList

D011TestReference

test_idstringrequired
test_level_indexinteger
notesstring