R85/2008-A-SE1-21.01 Rev. 1
| OIML Certification System | RISE |
| OIML Member State Sweden | OIML Certificate No. R85/2008-A-SE1-2021.01 Revision 1 |
| OIML CERTIFICATE ISSUED UNDER SCHEME A | |
| OIML Issuing Authority Name: RISE Research Institutes of Sweden AB Address: Box 857, SE-50115 Borås, Sweden Person responsible: Martin Tillander | |
| Applicant Name: Rosemount Tank Radar AB Postal address: Box 150, SE-435 23 Mölnlycke, Sweden Visiting address: Layoutvägen 1, SE-435 33 Mölnlycke, Sweden | |
| Manufacturer Name: Rosemount Tank Radar AB Postal address: Box 150, SE-435 23 Mölnlycke, Sweden Visiting address: Layoutvägen 1, SE-435 33 Mölnlycke, Sweden | |
| Identification of the certified type (the detailed characteristics will be defined in the additional pages and in appendix to this certificate) Raptor Tank Gauging System | |
| Designation of the module (if applicable) 5900S Radar Level Gauge | |
| This OIML Certificate attests the conformity of the above identified type (represented by the sample(s) identified in the OIML type evaluation report) with the requirements of the following Recommendation of the International Organization of Legal Metrology (OIML): OIML R 85 Edition (year):2008 | |
| Revision No. | Date | Description of the modification |
|---|---|---|
| First issue (CS) | 2021-02-18 | |
| Revision 1 | 2021-09-20 | Measurement range extended to 0-40 m Components added |
| OIML Certification System | RISE |
| OIML Member State Sweden | OIML Certificate No. R85/2008-A-SE1-2021.01 Revision 1 |
| ANNEX to an OIML Certificate of Conformity | |
| Issuing Authority Name: RISE Research Institutes of Sweden AB Address: Box 857, SE-50115 Borås, Sweden Person responsible: Martin Tillander | |
| Applicant Name: Rosemount Tank Radar AB Postal address: Box 150, SE-435 23 Mölnlycke, Sweden Visiting address: Layoutvägen 1, SE-435 33 Mölnlycke, Sweden | |
| Manufacturer Name: Rosemount Tank Radar AB Postal address: Box 150, SE-435 23 Mölnlycke, Sweden Visiting address: Layoutvägen 1, SE-435 33 Mölnlycke, Sweden | |
| Correction - | |
| Identification, signature and stamp The Issuing Authority RISE Research Institutes of Sweden AB Signature Date: 2021-09-20 | |
Identification and description of the certified type of tank radar
1 Design of the Raptor Tank Gauging System
- 1 Overview
1.2 Description of tested components
5900S Radar level gauge with:
Parabolic antenna 1P
Horn antenna 1H
Still-pipe array antenna 1A5
Still-pipe array antenna 1A6
Still-pipe array antenna 1A8
Still-pipe array antenna 1AA
Still-pipe array antenna 1AB
LPG/LNG antenna G1/G2/G3/Gx
2410 Tank Hub
2230 Graphical Field Display
2160/61 Field Communication Unit
2460 System Hub
2180 Field Bus Modem
Wireless 775 THUM adapter
Wireless 1420 Gateway
Emerson Wireless 1410 Gateway
Emerson Wireless 1410S Gateway with 781S
Emerson $ ^{\mathrm{TM}} $ Wireless 1410D Gateway with 781
Rosemount 702 Wireless Discrete Transmitter
Smart Wireless Gateway
General purpose PC with TankMaster for display of measured level
Printer.
Rosemount 5900S Radar Level Gauge
The Rosemount 5900S radar level gauge is an instrument for measuring the product level inside a tank. The 5900S can measure the level of almost any product, including bitumen, crude oil, refined products, aggressive chemicals, LPG and LNG. The Rosemount 5900S sends microwaves towards the surface of the product in the tank. The level is calculated based on the echo from the surface. No part of the 5900S is in contact with the product in the tank, and the antenna is the only part of the gauge that is exposed to the tank atmosphere. Different antennas can be used in order to meet the requirements of different applications:
| Antenna type | Model |
| Parabolic antenna | 1P |
Annex to OIML-certificate R85/2008-A-SE1-2021.01 Revision 1 dated 2021-09-20 page 2 of 5 pages
RISE Research Institutes of Sweden AB | Certification
Horn antenna 1H
Still-pipe array antenna 1A5,1A6,1A8,1AA,1AB
LPG/LNG antenna G1/G2/G4/Gx
Rosemount 2410 Tank Hub
The Rosemount 2410 tank hub acts as a supply to the connected field devices in the hazardous area using the intrinsically safe Raptor Tankbus. The Rosemount 2410 tank hub collects measurement data and
status information from field devices on a tank. It has two external buses for communication with various host systems.
Rosemount 2460 System Hub
The 2460 System Hub is a data concentrator and calculator that continuously polls and stores data from field devices such as radar level gauges and temperature transmitters in a buffer memory. When a request for data or calculated values is received over any of the communication ports (RS485, TRL/2, Ethernet etc), the 2460 sends data from a group of tanks from the updated buffer memory.
Rosemount 2230 Graphical Field Display
The Rosemount 2230 graphical field display presents inventory tank gauging data such as level, temperature, and pressure. The unit allows navigation through the different menus to provide all tank data, directly in the field. The Rosemount 2230 supports up to 10 tanks.
Rosemount 2160 Field Communication Unit
The 2160 field communication unit (FCU) is a data concentrator that continuously polls and stores data from field devices such as radar level gauges and temperature transmitters in a buffer memory. When a request for data is received, the FCU sends data from a group of tanks from the updated buffer memory.
Rosemount 2180 Field Bus Modem
The Rosemount 2180 field bus modem (FBM) is used for connecting a TankMaster PC to the TRL/2 communication bus. The 2180 is connected to the PC using either the RS232 or the USB interface.
2240S Multi-input Temperature Transmitter
The Rosemount 2240S Multi-input Temperature Transmitter provides multiple spot temperature measurement in liquid storage tanks. It is used for calculation of the average temperature of the liquid and corrects for stratification
Wireless 1410D Gateway
The Emerson Smart Wireless Gateway 1410 connects Wireless HART $ ^{\circledast} $ self-organizing networks with host systems and data applications
Wireless 1410S Gateway with 781S Smart Antenna
The Emerson Wireless 1410S Gateway is the next generation of wireless infrastructure. Network flexibility allows users to strengthen or add to WirelessHART $ ^{\mathrm{TM}} $ networks seamlessly, while connecting with host systems and data applications. The gateway uses the 781S Smart Antenna to enable flexible remote antenna locations of up to 1300 feet (400 m) allowing the gateway to be in an easily accessible location, while the 781S Smart Antenna can be in hazardous areas near your data points.
Wireless 1410D Gateway with 781 Field Link
Designed to connect WirelessHART networks with host systems and data applications, the Emerson Wireless 1410D Gateway with 781 Field Link allows users with limited safe locations to strengthen and add to wireless networks quickly and easily. This wireless gateway uses the 781 Field Link to enable flexible remote antenna locations of up to 650 feet (200 meters) allowing the gateway to be in the control room while placing the 781 Field Link into a hazardous area.
Wireless 1420 Gateway
The Emerson Smart Wireless Gateway 1420 connects Wireless HART $ ^{\circ} $ self-organizing networks with host systems and data applications
Wireless 775 THUM Adapter
The THUM Adapter is connected to a HART sub-device. With simple HART configuration, the THUM transmits the HART information from the sub-device into the Wireless network.
702 Wireless Discrete Transmitter
By using simple HART configuration, the transmitter converts the switch signal to a wireless-enabled signal. The 702 Wireless Discrete Transmitter is commonly used as a repeater to strengthen the Wireless HART network
TankMaster Software
The software identification number is 6.xx (where .xx is not concern-ing metrological functions).
TankMaster - provides configuration, service, set-up, inventory, and custody transfer functions for Rosemount Raptor systems and other supported instruments. TankMaster is designed to be used in the Microsoft $ \textcircled{R} $ Windows environment providing access to measurement data from Local Area Network.
TankMaster WinOpi - the program lets the operator monitor measured tank data. It includes alarm handling, batch reports, automatic report handling, historical data sampling as well as inventory calculations such as Volume, Observed Density and other parameters. A plant host computer can be connected for further processing of data.
TankMaster WinSetup - the program is a graphical user interface for installation, configuration and service of the different devices in the Rosemount Raptor system.
2 Technical data
- 1 Measurement range
| 5900Swith antenna: | Distance |
| -Horn antenna1H -Still-pipe array antenna1A5 -Still-pipe array antenna1A6 -Still-pipe array antenna1AA | 0-30m |
| -Parabolicantenna1P -Still-pipearrayantenna1AB -Still-pipe array antenna1A8 -LPG/LNG antennaG1/G2/G4/Gx | 0-40m |
- 2 Rated operating conditions
| Ambient temperatures | Low | -40℃ |
| High | +70℃ | |
| Relative humidity | upto100% | |
| DC mains voltage | 24-48VDC(-15%...+10%) | |
| AC mains voltage | 48-240VAC(-15%...+10%) | |
| Temperature extreme values | Liquid | N/A antenna not in contact with liquid |
| Medium above the liquid | -40-230℃(LPG/LNG antenna-170℃to90℃-55℃-90℃close to ball-valve) | |
| Pressure extreme values | Varies with antenna type-0.2-2bar(horn-andstill-pipe antenna)-0.2-10bar(parabolic antenna),upto25bar(LPGantenna) | |
| Liquid characteristics | N/A,liquid does not affect measurement performance | |
| Liquid density.extreme values | N/A,liquid density does not affect measurement performance | |
| Medium characteristics | Typical petroleum products | |
| Medium density.extreme values | ||
| Remarks:Normal petroleum products have no measurable influence on performance.Certain special products(e.g.ketons)may influence velocity of the radar wave and may result in performance outside m.p.e.See manufacturer's recommendation on which products to avoid.Tank design with internal floating roof may reduce influence for critical products. | ||
3 Technical documentation
The manuals include technical specifications and descriptions.
4 Securing
The housing and data plate can be sealed using wire or filling depending on national practice. Verification marks can be placed on top or side of each unit.
5 Marking/labelling/inscriptions
A data plate is placed on the side or top of each unit including the:
manufacturer's name,
type,
serial number,
year of manufacture,
EC type-approval number, (when applicable)
ranges of operations range and
CE mark (when applicable)