Skip to content

← R76

R76/2006-A-NL1-25.06 Rev. 0

Applicant
Shinko Denshi Co., Ltd.
Issuer
NL1
Issuing year
2025
Status
Valid

Source PDF (certificates/R76/2006/r76-2006-nl1-2025-06-rev0.pdf) · extracted by OCR from the digitalized tier of the corpus.

R76/2006-A-NL1-25.06 Rev. 0

OIML Certificate

OIML Member State The Netherlands

Number R76/2006-A-NL1-25.06 revision 0 Project number 3881188 Page 1 of 2

Issuing authority

NMi Certin B.V.

Person responsible: M.Ph.D. Schmidt

Applicant and Manufacturer

Shinko Denshi Co., Ltd.

1-52-1 Itabashi, Itabashi-ku

Tokyo 173-0004

Japan

Identification of the certified type

A Non-automatic weighing instrument Type : CJC series

Characteristics

See next page

This OIML Certificate is issued under scheme A.

This Certificate attests the conformity of the above identified Type (represented by the sample(s) identified in the OIML Test Report) with the requirements of the following Recommendation of the International Organization of Legal Metrology (OIML):

OIML R 76-1:2006 for accuracy class 11

This Certificate relates only to the metrological and technical characteristics of the type of measuring instrument covered by the relevant OIML International Recommendation above-identified. This Certificate does not bestow any form of legal international approval.

Important note: Apart from the mention of the Certificate's reference number and the name of the OIML Member State in which the Certificate was issued, partial quotation of the Certificate and of the associated OIML Test Report(s) is not permitted, although either may be reproduced in full.

Issuing Authority

NMi Certin B.V., OIML Issuing Authority NL1 2 June 2025

Certification Board

This document is issued under the provision that no liability is accepted and that the applicant shall indemnify third-party liability.

OIML Certificate

OIML Member State The Netherlands

Number R76/2006-A-NL1-25.06 revision 0

Project number 3881188

Page 2 of 2

The conformity was established by the results of tests and examinations provided in the associated reports:

No. NMi-3881188-02 dated 2 June 2025 that includes 36 pages;

No. NMi-3881188-01 dated 2 June 2025 that includes 31 pages;

  • No. NMi-3881188-03 dated 2 June 2025 that includes 31 pages;

  • No. NMi-3881188-04 dated 2 June 2025 that includes 18 pages;

  • No. NMi-3881188-05 dated 2 June 2025 that includes 21 pages;

  • No. NMi-3881188-06 dated 2 June 2025 that includes 18 pages;

  • No. NMi-3881188-07 dated 2 June 2025 that includes 21 pages.

Characteristics of the non-automatic weighing instrument:

Accuracy class11
Maximum capacityMax≤820g Max≤0.82kg Max≤4100ctMax≤15000g Max≤15kg Max≤75000ct
Verification scale intervale≥0.01g e≥0.00001kg e≥0.05cte≥0.1g e≥0.0001kg e≥0.5ct
Actual scale intervale=d
Weighing rangeSingle interval
Maximum number of scale intervals (one weighing range)n≤82000
TareT≤-Max
Temperature range+5℃/+35℃
Power supply voltage100-240VAC50/60Hz to5,95VDC (byAC/DCplug-inpower supply), Or6VDC(bybattery)
Software identificationChecksum:8969

Revision History

RevisionDateChange(s)
02025-06-02Initial issue.