R76/2006-A-NL1-20.50 Rev. 4

Applicant
Dibal S.A
Issuer
NL1
Issuing year
2026
Status
Valid

Source PDF (certificates/R76/2006/r76-2006-nl1-2020-50-rev4.pdf) · extracted by OCR from the digitalized tier of the corpus.

R76/2006-A-NL1-20.50 Rev. 4

OIML Certificate

OIML Member State The Netherlands

Number R76/2006-A-NL1-20.50 revision 4 Project number 4059453 Page 1 of 3

Issuing authority

NMi Certin B.V. Person responsible: M.Ph.D. Schmidt

Applicant and Manufacturer

Dibal S.A.

Astintze 26

48160 Derio

Spain

Identification of the certified type

A Non-automatic weighing instrument Type CS Series

Characteristics

See next page

This OIML Certificate is issued under scheme A.

This Certificate attests the conformity of the above identified Type (represented by the sample(s) identified in the OIML Test Report) with the requirements of the following Recommendation of the International Organization of Legal Metrology (OIML):

OIML R 76-1:2006 for accuracy class III

This Certificate relates only to the metrological and technical characteristics of the type of measuring instrument covered by the relevant OIML International Recommendation above-identified. This Certificate does not bestow any form of legal international approval.

Important note: Apart from the mention of the Certificate's reference number and the name of the OIML Member State in which the Certificate was issued, partial quotation of the Certificate and of the associated OIML Test Report(s) is not permitted, although either may be reproduced in full.

Issuing Authority

NMi Certin B.V., OIML Issuing Authority NL1 25 June 2026

Certification Board

This document is issued under the provision that no liability is accepted and that the applicant shall indemnify third-party liability.

Reproduction of the complete document only is permitted.

OIML Certificate

OIML Member State The Netherlands

Number R76/2006-A-NL1-20.50 revision 4

Project number 4059453

Page 2 of 3

The conformity was established by the results of tests and examinations provided in the associated reports:

ModuleTypeReportIssue datePages
IndicatorCS SeriesNMi-1902587-0114 December 201853
NMi-1902587-0214 December 201812
NMi-1902587-0314 December 201812
NMi-2431310-0118 March 202012
NMi-2532570-0130 December 202013
NMi-3700931-0115 November 202312
NMi-3700931-0215 November 202322
NMi-3842173-018 August 202420
NMi-4059453-0125 June 202615
Load cellL6DNMi-10200947-0724 December 202059
NMi-10200947-0824 December 202059
LAB...R60/2000-NL1-10.0717 May 201040
NMi-12200582-0123 August 201352
NMi-3534839-0129 November 202251

Characteristics of the non-automatic weighing instrument:

Accuracy classIII
Maximum capacity6kg≤Max≤100kg
Verification scale intervale≥2g
Weighing rangesSingle interval Multi-interval Multiple range
Maximum number of scale intervals (one weighing range)n≤6000
Maximum number of scale intervals (multi-interval)n≤3000 (per partial weighing range)
Maximum number of partial weighing ranges2
Maximum number of scale intervals (multiple range)n≤3000 (per weighing range)
Maximum number of weighing ranges2
TareTare≤-Max+e for single interval Tare≤-Max1+e1 for multi-interval and multiple range instruments
Load cell excitation voltage5VDC
Minimum input voltage per verification scale interval1μV

OIML Certificate

OIML Member State The Netherlands

Number R76/2006-A-NL1-20.50 revision 4

Project number 4059453

Page 3 of 3

Minimum load cell resistance300Ω
Maximum load cell resistance500Ω
Load cell connection4-wire
Temperature range0℃/40℃
Power supply voltage110-230V AC 50/60Hz24V DC
ApplicationIntended to be used for direct sales to the public
Software identificationWeighing CPU FirmwareVersion:2.0.3
PC Software checksumsPHP:F244B8F0
JPOS:ADD09326
Net:2ADDCC7C

Software:

  • The software identification is displayed permanently in the weighing window by the software, or it is displayed when the text "Version", located in the weighing window, is pressed.

  • The instrument has loadable software.

Revision History

This revision replaces the previous versions.

RevisionDateChange(s)
02020-12-30Initial issue.
12024-02-13Addition of reports.
22024-08-07Addition of reports and changes in table of characteristics.
32024-09-03Correction of type evaluation report number.
42026-06-25Addition of reports and changes in table of characteristics.