Skip to content

← R76

R76/2006-A-CZ1-26.01

Applicant
ADE Germany GmbH
Issuer
CZ1
Issuing year
2026
Status
Valid

Source PDF (certificates/R76/2006/r76-2006-cz1-2026-01.pdf) · extracted by OCR from the digitalized tier of the corpus.

R76/2006-A-CZ1-26.01

OIML Certification SystemCMIV3112
OIML Member State Czech RepublicOIML Certificate No. R76/2006-A-CZ1-26.01
OIML CERTIFICATE ISSUED UNDER SCHEME A
OIML Issuing Authority Name: Czech Metrology Institute Address: Okružní 31 638 00 Brno Czech Republic Person responsible: Jan Kalandra
Applicant Name: ADE Germany GmbH Address: Neuer Höltigbaum 15 22143 Hamburg Germany
Manufacturer Name: ADE Germany GmbH Address: Neuer Höltigbaum 15 22143 Hamburg Germany
Identification of the certified type (the detailed characteristics will be defined in the additional pages) Indicator for non-automatic weighing instruments. type: MZ3042
Designation of the module (if applicable)
This OIML Certificate attests the conformity of the above identified type (represented by the sample(s) identified in the OIML type evaluation report) with the requirements of the following Recommendation of the International Organization of Legal Metrology (OIML): OIML R 76 Edition (year): 2006 For accuracy class: III
This OIML Certificate relates only to metrological and technical characteristics of the type of measuring instrument covered by the relevant OIML Recommendation identified above. This OIML Certificate does not bestow any form of legal international approval.
The conformity was established by the results of tests and examinations provided in the associated. Test report No. 6012-PT-R0046-25 dated 09.01.2026 that includes 51 pages. Test report No. 6012-PT-R0048-25 dated 13.01.2026 that includes 17 pages. Test report No. 6012-PT-R0049-25 dated 09.01.2026 that includes 36 pages. Test report No. 8551-PT-E0338-25 dated 12.11.2025 that includes 37 pages. OIML type evaluation report: No. 0511-ER-N021-25 dated 14 January 2026 that includes 12 pages
The technical documentation relating to the identified type is contained in documentation file: 0511-UL-N021-25 OIML Certificate History
Revision No.DateDescription of the modification
-23 January 2026Issuing of certificate
The OIML Issuing Authority Ing. František Staněk, PhD. Deputy Director of Certification Body Date: 23 January 2026
Important note: Apart from the mention of the Certificate's reference number and the name of the OIML Member State in which the Certificate is issued, partial quotation of the Certificate and of the associated OIML type evaluation report(s) is not permitted, although either may be reproduced in full.

1 Characteristics of the instrument

The electronic indicator type MZ3042 is intended for use as indicator for non-automatic weighing instruments for medical applications. The instrument is a Class III, self-indicating weighing instrument with single- or dual-range, an external AC mains adapter and an internal rechargeable battery (optional).

ANSICHT1 ( 1:1 )

ANSICHT 2 ( 1:2 )

ADEGewicht 0,54 kg12
ATT Nr. GmbH GmbH GmbH
Att Nr. GmbH GmbH GmbH
DatumNameBemannung Indikator M23042-xx_STA08-xx
Gewinn10.09.2026A Schrij
Gewinn25.03.2025S Zastraw
Gewinn25.03.2025P Mark
Zeichnungnummer Nr. Nr. Nr.Produktausgabe Indikator - IND2
DateTagesdatum und Monatdatum Indikator - INDA3

2 Metrological characteristics

TypeMZ3042
Ingres protection ratingIP52
DisplayLCD
Operating temperature-10℃/+45℃
Storage temperature-20℃/+60℃
Accuracy class OIML R76III
The applied error fraction pi0.5
Weighing software versionO.1.yy
Application software versionA.x.yy
Operating systemEmbedded
Primary indication unitkg
Weighing range configurationSingle or dual range
Max≤3000kg
Verification Scale interval e≥0.5g
Actual Scale interval d≥0.1g
Maximum number of Verification Scale Intervals(per Weighing Range)n≤3000
Maximum number of actual scale interval≤10000
Maximum subtractive Tare effect-Max

Český metrologický institut

-3-

Minimum signal voltage per verification scale interval(μV/e)0,5
Load cell excitation voltage(V)3,3
Load cell excitation waveform(V)DC
Minimal load cell impedance(Ω)87
Maximal load cell impedance(Ω)1200
Load cell connection4-wire,6-wire
Maximum value of the cable length per cross wire section between the indicator and the junction box or load cells50m/mm2In case sense technology is not used the load cells are connected directly without junction box or extension cable
High resolution mode10x
Power supply,voltage4x AA 1,5V DC Batteries or6.0VDC,1.0A by AC/DC plug-in power supply or1x Lithium-Ion 3,7V Battery Pack

3 Devices and functions

  • determination of stability of equilibrium

  • indication of stable equilibrium

  • zero indicating

  • initial zero setting $ \leq 20% $ Max

  • zero tracking $ \leq 4 % $ Max

  • semi-automatic zero setting $ \leq 4 % $ Max

  • semi-automatic tare balancing (subtractive)

  • Preset tare device

  • Hold function

3.1 Additional Instrument Functions

In addition to its primary weighing function, the instrument incorporates supplementary features including:

  • Body Mass Index (BMI) calculation

  • Length measurement

  • Print function

These additional functions have not been tested for compliance.

Český metrologický institut

-3-