R76/2006-A-NL1-20.02
OIML Certificate
OIML Member State The Netherlands
Number R76/2006-A-NL1-20.02 Project number 2393679 Page 1 of 2
Issuing authority
NMi Certin B.V. Person responsible: F. van Booma-de Smit
Applicant and Manufacturer
Shanghai Teraoka Electronics Co., Ltd.
No.6058 of Nan Ting Road
Ting Ling Town, Jin Shan District
Shanghai 201505
P.R. China
Identification of the certified type
A Non-automatic weighing instrument Type : RM-90
Characteristics
See next page
This OIML Certificate is issued under scheme A.
This Certificate attests the conformity of the above identified Type (represented by the sample(s) identified in the OIML Test Report) with the requirements of the following Recommendation of the International Organization of Legal Metrology (OIML):
OIML R 76 - Edition 2006 for accuracy class
This Certificate relates only to the metrological and technical characteristics of the type of measuring instrument covered by the relevant OIML International Recommendation above-identified. This Certificate does not bestow any form of legal international approval.
Important note: Apart from the mention of the Certificate's reference number and the name of the OIML Member State in which the Certificate was issued, partial quotation of the Certificate and of the associated OIML Test Report(s) is not permitted, although either may be reproduced in full.
Issuing Authority
NMi Certin B.V., OIML Issuing Authority NL1 9 January 2020
Certification Board
This document is issued under the provision that no liability is accepted and that the applicant shall indemnify third-party liability.
OIML Certificate
OIML Member State The Netherlands
Number R76/2006-A-NL1-20.02
Project number 2393679
The conformity was established by the results of tests and examinations provided in the associated OIML Type Evaluation Reports:
Page 2 of 2
No. NMi-2393679-01 dated 9 January 2020 that includes 36 pages;
No. NMi-2379863-01 dated 6 January 2020 that includes 44 pages.
Characteristics of the non-automatic weighing instrument:
| Accuracy class | $\textcircled{111}$ |
| Maximum capacity | 3/6/15/30kg |
| Verification scale interval | e=1/2/5/10g |
| Weighing range | Multi-interval |
| Maximum number of scale intervals(multi-interval) | n≤3000(per partial weighing range) |
| Maximum number ofpartial weighing ranges | 4 |
| Tare | T≤-Max1 |
| Temperature range | -10℃/+40℃ |
| Power supply voltage | 220-240V AC 50/60Hz |
| Application | Intended to be used for direct sales to the public |
| Software identification | VR01.xx(x=0...9) |