Skip to content

← R76

R76/2006-A-NL1-19.51

Applicant
Dibal S.A
Issuer
NL1
Issuing year
2019
Status
Valid

Source PDF (certificates/R76/2006/r076-2006-nl1-2019-51.pdf) · extracted by OCR from the digitalized tier of the corpus.

R76/2006-A-NL1-19.51

OIML Certificate

OIML Member State The Netherlands

Number R76/2006-A-NL1-19.51 Project number 2383771 Page 1 of 3

Issuing authority NMi Certin B.V. Person responsible: F. van Booma - de Smit

Applicant and Manufacturer Dibal S.A.

Astintze Kalea, 26 - Pol. Ind. Neinver

48160 Derio, Vizcaya

Spain

Identification of the An Indicator certified type Type

Characteristics

This OIML Certificate is issued under scheme A.

See next page

This Certificate attests the conformity of the above identified Type (represented by the sample(s) identified in the OIML Test Report) with the requirements of the following Recommendation of the International Organization of Legal Metrology (OIML):

OIML R 76 - Edition 2006 for accuracy class or

This Certificate relates only to the metrological and technical characteristics of the type of measuring instrument covered by the relevant OIML International Recommendation above-identified. This Certificate does not bestow any form of legal international approval.

Important note: Apart from the mention of the Certificate's reference number and the name of the OIML Member State in which the Certificate was issued, partial quotation of the Certificate and of the associated OIML Test Report(s) is not permitted, although either may be reproduced in full.

Issuing Authority

NMi Certin B.V., OIML Issuing Authority NL1 22 November 2019

Certification Board

This document is issued under the provision that no liability is accepted and that the applicant shall indemnify third-party liability.

OIML Certificate

OIML Member State The Netherlands

Number R76/2006-A-NL1-19.51

Project number 2383771

Page 2 of 3

The conformity was established by the results of tests and examinations provided in the associated OIML Type Evaluation Report:

  • No. NMi-2382771-01 dated 20 November 2019 that includes 55 pages.

Characteristics of the indicator:

Accuracy classor
Weighing range(s)Single interval Multi-interval Multiple range
TareT≤-Max+e for single interval instruments T≤-Max1+e1 for multi-interval instruments T≤-Max2+e2 for multiple range instruments
Maximum number of scale intervals (one weighing range)n≤6000
Maximum number of scale intervals (multi-interval)n≤3000 (per partial weighing range)
Maximum number of partial weighing ranges2
Maximum number of scale intervals (multiple range)n≤3000 (per weighing range)
Maximum number of weighing ranges2
Load cell excitation voltage5V DC
Minimum signal input voltageUmin=0mV
Minimum input voltage per verification scale interval1μV
Minimum load cell resistance21Ω
Maximum load cell resistance1131Ω
Fraction of the maximum permissible error0.5
Load cell connection6-wire(remote sensing)or4-wire
Maximum value of the cable length per cross wire section between the indicator and the junction box or load cells2997.9m/mm2 In case a 4-wire connection is used,the load cells are connected directly without junction box
Temperature range0℃/+40℃
Power supply voltage110-230V AC 50/60Hz
ApplicationCan be used for direct sales to the public
Firmware identification2.0.3

OIML Certificate

OIML Member State The Netherlands

Number R76/2006-A-NL1-19.51

Project number 2383771

Page 3 of 3

The indicator has loadable user application software that runs on Linux or Windows system.

PC user software:

FrameworkJPOSPHP.NET
Software identification2.x.x(x=0...9)1.x.x(x=0...9)3.x.x.x(x=0...9)
ChecksumADD09326F244B8F02ADDCC7C

The user software identification is displayed permanently on the main screen (for JPOS and PHP) or by pressing "version" on the main screen (for .NET).

The identification number of weighing firmware and user software can both be displayed after opening the application "Test and Adjust" and selecting "Version".