Skip to content

← R76

R76/2006-A-GB1-18.08

Applicant
CAS Corporation
Issuer
GB1
Issuing year
2018
Status
Valid

Source PDF (certificates/R76/2006/r076-2006-gb1-2018-08.pdf) · extracted by OCR from the digitalized tier of the corpus.

R76/2006-A-GB1-18.08

NMOOIML Certification System
OIML Member State United Kingdom of Great Britain and Northern IrelandOIML Certificate No. R76/2006-A-GB1-18.08
OIML CERTIFICATE ISSUED UNDER SCHEME A
OIML Issuing AuthorityNMO Stanton Avenue Teddington TW11 0JZ United Kingdom
Person responsibleMannie Panesar-Head of Technical Services
ApplicantCAS Corporation #262, Geurugogae-ro Gwangjeok-myeon Yangju-si Gyeonggi-do Republic of Korea
ManufacturerThe applicant
Identification of the certified typeCI-2001 Series (the detailed characteristics are defined in the Descriptive Annex)
This OIML Certificate attests the conformity of the above identified type (represented by the sample(s) identified in the OIML type evaluation report) with the requirements of the following Recommendation of the International Organization of Legal Metrology(OIML):
OIML R 76-1, Edition:2006
For accuracy class:III and III
Issue date:24 October 2018
The OIML Issuing Authority
Grégory Glas Technical Manager For and on behalf of the Head of Technical Services
This OIML Certificate relates only to metrological and technical characteristics of the type of measuring instrument covered by the relevant OIML Recommendation identified above. This OIML Certificate does not bestow any form of legal international approval.
The conformity was established by the results of tests and examinations provided in the associated OIML type evaluation report: No. P02431-1 dated 24 October 2018 that includes 16 pages
The technical documentation relating to the identified type is contained in documentation file: No. P02431-1-D dated 24 October 2018
OIML Certificate History
Revision No.DateDescription of the modification
Revision 024 October 2018Certificate first issued.
---
No revisions have been issued.
Important note: Apart from the mention of the Certificate's reference number and the name of the OIML Member State in which the Certificate is issued, partial quotation of the Certificate and of the associated OIML type evaluation report(s) is not permitted, although either may be reproduced in full.

DESCRIPTIVE ANNEX

Characteristics of the instrument:

This indicating device, designated the CI-2001, is designed to be used as part of a single range, Class III or IIII, non-automatic weighing instrument. The indicators are self-indicating and mains-powered.

The instruments are not designed for direct sales to the public.

Main features:

  • Plastic/ Stainless Steel enclosure

  • LED (CI-2001A) or LCD(CI-2001B) display

  • Operator keypad with 6 navigation and function keys

  • LED enunciators (CI-2001A)

  • LCD enunciators (CI-2001B)

Devices:

  • Initial zero setting device on power up ( $ \leq 20% $ Max)

  • Semi-automatic zero setting ( $ \leq 4 % $ Max)

  • Zero tracking (optional) ( $ \leq $ 4% Max)

  • Semi-automatic subtractive tare balancing (T = -Max)

  • Gross and Net enunciators

  • Gross/Net toggle

  • Zero enunciator

  • Indication of stable equilibrium

  • Gravity compensation

Interfaces:

  • Load cell connection

RS232/485

USB

Load cell:

Any compatible load cell(s) may be used providing the following conditions are met:

  • There is a respective OIML Certificate of Conformity (R60) issued for the load cell.

  • The certificate contains the load cell types and the necessary load cell data required for the manufacturer's declaration of compatibility of modules, and any particular installation requirements. A load cell marked NH is allowed only if humidity testing to R76 has been conducted on this load cell.

  • The compatibility of the load cells and indicator is established by the manufacturer by means of the compatibility of modules calculation at the time of verification.

  • The load cell transmission conforms to a standard type.

Alternatively, the instruments may have the following specifications, and designations (with x: A or B):

Designation(x can be A or B)Dead load of load receptorMax(kg)e=(kg)Load cell type(CAS)Load cellEmaxNumber of load cells
CI-2001x/SPS(SUS)-63kg60.002BCLS-10L101
CI-2001x/SPS(SUS)-153kg150.005BCLS-20L201
CI-2001x/SPS(SUS)-303kg300.01BCLS-30L301
CI-2001x/SPS(SUS)-605kg600.02BCLS-60L601
CI-2001x/SPS(SUS)-1505kg1500.05BCLS-180L1801
CI-2001x/SPS-63kg60.002BCL-10L101
CI-2001x/SPS-153kg150.005BCL-20L201
CI-2001x/SPS-303kg300.01BCL-30L301
CI-2001x/SPS-605kg600.02BCL-60L601
CI-2001x/SPS-1505kg1500.05BCL-180L1801
CI-2001x/0.5HFS080844kg5000.2BSA-2502504
CI-2001x/0.5HFS100854kg5000.2BSA-2502504
CI-2001x/0.5HFS101065kg5000.2BSA-2502504
CI-2001x/0.6HFS080844kg6000.2BSA-2502504
CI-2001x/1HFS101065kg10000.5BSA-5005004
CI-2001x/1HFS101277kg10000.5BSA-5005004
CI-2001x/1HFS111178kg10000.5BSA-5005004
CI-2001x/1HFS121292kg10000.5BSA-5005004
CI-2001x/1HFS1215118kg10000.5BSA-5005004
CI-2001x/2HFS121292kg20001BSA-1T10004
CI-2001x/2HFS1215118kg20001BSA-1T10004
CI-2001x/2HFS1515145kg20001BSA-1T10004
CI-2001x/3HFS1515145kg30001BSA-2T20004
CI-2001x/3HFS1518178kg30001BSA-2T20004
CI-2001x/3HFS1520198kg30001BSA-2T20004
CI-2001x/5HFS1515145kg50002BSA-2T20004
CI-2001x/5HFS1518178kg50002BSA-2T20004
CI-2001x/5HFS1520198kg50002BSA-2T20004
CI-2001x/0.5UFS120838kg5000.2BSA-2502504
CI-2001x/1UFS120838kg10000.5BSA-5005004
CI-2001x/1.5UFS120838kg15000.5BSA-1T10004
CI-2001x/2UFS120838kg20001BSA-1T10004
CI-2001x/3UFS120838kg30001BSA-2T20004
CI-2001x/4UFS120838kg40002BSA-2T20004
CI-2001x/0.5BFS121228kg5000.2BSA-2502504
CI-2001x/1BFS121228kg10000.5BSA-5005004
CI-2001x/2BFS121228kg20001BSA-1T10004

Technical data (indicator):

Power supply12 VDC via mains adapter
Maximum number of scale intervals4,000(Class III) 1,000(Class III)5,000(Class III) 1,000(Class III)
Operating temperature range-10℃ to+40℃0℃ to+40℃
Maximum Tare value-Max
Load cell excitation voltage5VDC
Minimum load cell impedance87.5Ω
Maximum load cell impedance1100Ω
Minimum input voltage per verification scale interval2μV
Measuring range minimum voltage0mV
Measuring range maximum voltage11mV
Fraction of maximum permissible errorPi=0.5
Load cell cable(from indicator to load cell junction box)-Maximum length2 meters(4-wire configuration) 3.5m/mm2(6-wire configuration)

Software:

The software is held in firmware on the circuit board, and has the identification number "V1.xx", with xx reflecting non-legally relevant changes. The software version number is displayed at power-up.

Download of software is only possible by accessing the main board inside the sealed enclosure.

Access to the legally relevant parameters is prevented by a switch on the main board.

Sealing:

Access to the electronics, access to the switch described in Software section and the load cell connection are sealed using a tamper-evident method

Alternatives:

Having the instruments manufactured by the following companies:

CAS (Zhejiang) Electronics Co., Ltd 99# Changjiang Road Jiashan County Zhejiang Province China