Skip to content

← R76

R76/2006-A-NL1-19.23 Rev. 2

Applicant
Rice Lake Weighing Systems
Issuer
NL1
Issuing year
2026
Status
Valid

Source PDF (certificates/R76/2006/r76-2006-nl1-2019-23-rev2.pdf) · extracted by OCR from the digitalized tier of the corpus.

R76/2006-A-NL1-19.23 Rev. 2

Page 1

O I M L C e r t i f i c a t e




OIML Member State                         Number R76/2006-A-NL1-19.23 revision 2
The Netherlands                                        Project number 3681123
                                              Page 1 of 3


Issuing authority      NMi Certin B.V.
                      Person responsible: M.Ph.D. Schmidt

Applicant and          Rice Lake Weighing Systems
Manufacturer         230 W Coleman St.
                        Rice Lake, WI 54868
                      United States of America

Identification of the   A Indicator or Terminal
certified type         Type                                                        :  1280 Enterprise series

Characteristics         See next page


This OIML Certificate is issued under scheme A.

This Certificate attests the conformity of the above identified Type (represented by the sample(s)
identified in the OIML Test Report) with the requirements of the following Recommendation of the
International Organization of Legal Metrology (OIML):

                 OIML R 76-1:2006 for accuracy class  III  or  IIII

This Certificate relates only to the metrological and technical characteristics of the type of measuring
instrument covered by the relevant OIML International Recommendation above-identified.
This Certificate does not bestow any form of legal international approval.

Important note: Apart from the mention of the Certificate’s reference number and the name of the
OIML Member State in which the Certificate was issued, partial quotation of the Certificate and of
the associated OIML Test Report(s) is not permitted, although either may be reproduced in full.





Issuing Authority     NMi Certin B.V., OIML Issuing Authority NL1
                    29 January 2026

                          Certification Board

NMi Certin B.V.                    This document is issued under the     This document is digitally
Thijsseweg 11                     provision that no liability is           signed and sealed. The
2629 JA Delft                   accepted and that the applicant        digital signature can be
The Netherlands                    shall indemnify third-party liability.    verified in the blue
T +31 88 6362332                                                   ribbon on top of the
certin@nmi.nl                 The notification of NMi Certin B.V.     electronic version of this
www.nmi.nl                      as Issuing Authority can be verified     certificate.
                                   at www.oiml.org

Page 2

O I M L C e r t i f i c a t e




OIML Member State                         Number R76/2006-A-NL1-19.23 revision 2
The Netherlands                                        Project number 3681123
                                              Page 2 of 3


The conformity was established by the results of tests and examinations provided in the associated
reports:
-  No. NMi-14200409-01 dated 29 February 2016 that includes 22 pages;
-  No. NMi-14200409-02 dated 29 February 2016 that includes 50 pages;
-  No. NMi-14200409-03 dated 29 February 2016 that includes 22 pages;
-  No. NMi-2166254-01 dated 10 May 2019 that includes 11 pages;
-  No. NMi-3681123-01 dated 29 January 2026 that includes 15 pages.

Characteristics of the indicator:

                                                                                    Digital load cells or
 Configuration                                Analog load cells
                                                                     weighing module

 Accuracy class                                                                    III  or  IIII
                                                                  Single interval
 Weighing ranges                                                  Multi-interval
                                                               Multiple range

 Maximum number of scale intervals                                                                          -
                                         n  10000 divisions (one weighing range)

 Maximum number of scale intervals             n  10000 divisions                        -
 (multi-interval)                                (per partial weighing range)

 Maximum number of partial weighing                                                                      -
                                                     3
 ranges

 Maximum number of scale intervals             n  10000 divisions                        -
 (multiple range)                                   (per weighing range)

 Maximum number of weighing ranges                   3                                    -

 Load cell excitation voltage                          10 V DC                               -

 Load cell power supply voltage                                           -                   15 V DC

 Minimum input voltage per verification                                                                    -
                                                             1,0 µV
 scale interval

 Minimum load cell resistance                          23                                   -

 Maximum load cell resistance                        1050                                 -

 Fraction of the maximum permissible error                  0,5                     0

                                         6 wire with sense technology,                -
 Load cell connection
                                   may be configured as 4 wire

                                                 395 m/mm2
                                                  In case sense technology is not
 Maximum value of the cable length per
                                             used the load cells are
 cross wire section between the indicator                                                                   -
                                           connected directly without
 and the junction box or load cells
                                                 junction box or extension
                                                          cable

Page 3

O I M L C e r t i f i c a t e




OIML Member State                         Number R76/2006-A-NL1-19.23 revision 2
The Netherlands                                        Project number 3681123
                                              Page 3 of 3



 Maximum number of load platforms                              8

                temperature range                           -10 °C / +40 °C
 Climatic
                 humidity                                non-condensing
 environment
                 intended location                                 closed

 Electromagnetic environment class                               E2

                                             100 – 240 V AC 50/60 Hz (for AC version)
 Power supply voltage
                                                  9 – 30 V DC (for DC version)

                                                    Version number: V1.xx.xx or V2.xx.xx
 Software identification 1280 firmware
                                                   (xx = 00…99 for the legally non-relevant software)
Software:
-   The identification number for 1280 firmware will be displayed after pressing the key sequence:
   Menu -> Audit trail.
-   The indicator has embedded software.





Revision History

This revision replaces the previous versions.


   Revision   Date              Change(s)

  0          2019-05-10           Initial issue.

  1          2022-02-11        Terminal option added.

  2          2026-01-29       Adding alternative processer. Correction the format of software
                                     identification.