Skip to content

← R76

R76/2006-A-CN2-24.19 Rev. 0

Applicant
Dibal S.A
Issuer
CN2
Issuing year
2024
Status
Valid

Source PDF (certificates/R76/2006/r76-2006-cn2-2024-19-rev0.pdf) · extracted by OCR from the digitalized tier of the corpus.

R76/2006-A-CN2-24.19 Rev. 0

Page 1

O I M L C e r t i f i c a t e




OIML Member State                         Number R76/2006-A-NL1-24.19 revision 0
The Netherlands                                        Project number 3834855
                                              Page 1 of 3


Issuing authority      NMi Certin B.V.
                      Person responsible: M.Ph.D. Schmidt

Applicant and          Dibal S.A.
Manufacturer          Astintze Kalea, 24 - Pol. Ind. Neinver
                     48160 Derio, Vizcaya
                      Spain

Identification of the   A Non-automatic weighing instrument
certified type         Brand                                                      :  DIBAL
                    Type                                                        :  500, 500-SW and D-900 Series

Characteristics         See next page


This OIML Certificate is issued under scheme A.

This Certificate attests the conformity of the above identified Type (represented by the sample(s)
identified in the OIML Test Report) with the requirements of the following Recommendation of the
International Organization of Legal Metrology (OIML):

                 OIML R 76-1:2006 for accuracy class  III  or  IIII

This Certificate relates only to the metrological and technical characteristics of the type of measuring
instrument covered by the relevant OIML International Recommendation above-identified.
This Certificate does not bestow any form of legal international approval.

This certificate and supporting reports comply with the requirements of OIML-CS-PD-07 clause 6.2.

Important note: Apart from the mention of the Certificate’s reference number and the name of the
OIML Member State in which the Certificate was issued, partial quotation of the Certificate and of
the associated OIML Test Report(s) is not permitted, although either may be reproduced in full.





Issuing Authority     NMi Certin B.V., OIML Issuing Authority NL1
                     8 August 2024

                          Certification Board

NMi Certin B.V.                    This document is issued under the     This document is digitally
Thijsseweg 11                     provision that no liability is           signed and sealed. The
2629 JA Delft                   accepted and that the applicant        digital signature can be
The Netherlands                    shall indemnify third-party liability.    verified in the blue
T +31 88 6362332                                                   ribbon on top of the
certin@nmi.nl                 The notification of NMi Certin B.V.     electronic version of this
www.nmi.nl                       as Issuing Authority can be verified     certificate.
                                   at www.oiml.org

Page 2

O I M L C e r t i f i c a t e




OIML Member State                         Number R76/2006-A-NL1-24.19 revision 0
The Netherlands                                        Project number 3834855
                                              Page 2 of 3


The conformity was established by the results of tests and examinations provided in the associated
reports:
 Module      Type          Report                         Issue date          Pages
                           NMi-11200653-01           30 November 2012   37
                           NMi-12200102-01           23 July 2012        14
               500-SW    NMi-12200562-01           11 December 2012   30
                           NMi-13200410-01           9 October 2013     17
                           NMi-13200410-02           9 October 2013     10
                            R76/2006-NL1-10.28A        26 August 2010     47
                             R76/2006-NL1-10.28B        26 August 2010     16
   Indicator
                           NMi-10200492-01           21 December 2010   17
                           NMi-10201100-01           27 April 2011       35
                  500      NMi-11200395-01           22 July 2011        32
                           NMi-13200724-01           12 March 2014      38
                           NMi-15200175-01           13 April 2015       14
                           NMi-1901266-01            4 October 2017     12
                           NMi-2399743-01            21 November 2019   13
                           NMi-10200947-07           24 December 2020   59
                L6D
                           NMi-10200947-08           24 December 2020   59
                             R60/2000-NL1-10.07         17 May 2010        40
  Load cell
             LAB…     NMi-12200582-01           23 August 2013     52
                           NMi-3534839-01            29 November 2022   51

Characteristics of the non-automatic weighing instrument:

 Accuracy class                                                                    III  or  IIII
 Maximum capacity                                     6 kg  Max  30 kg
 Verification scale interval                                    e  2 g
                                                                Single interval
 Weighing ranges                                                 Multi-interval
                                                             Multiple range
 Maximum number of scale intervals                     n  3000 divisions
 (Single interval)
                                                 n  3000 divisions Maximum number of scale intervals
                                                (per weighing range or partial weighing range)
 Maximum number of
                                                            2
 partial weighing ranges
 Load cell excitation voltage                                  5 V DC
 Minimum input voltage per verification
                                                                      1,0 µV
 scale interval
 Minimum load cell resistance                                 300 
 Maximum load cell resistance                                 900 

Page 3

O I M L C e r t i f i c a t e




OIML Member State                         Number R76/2006-A-NL1-24.19 revision 0
The Netherlands                                        Project number 3834855
                                              Page 3 of 3



                                                                    4-wire, or
 Load cell interface
                                                       6-wire with sense technology
 Maximum number of load platforms                             1
 Temperature range                                            -10 °C / +40 °C
                                                  110 – 230 V AC 50/60 Hz or
 Power supply voltage                         12 – 24 V DC via external power supply or
                                                                  internal battery
 Application                                Intended to be used for direct sales to the public
                                          W100 for the 500 Series;
 Software identification
                                     W200 for the 500-SW Series and D-900.





Revision History


   Revision   Date              Change(s)

  0          2024-08-07           Initial issue.