R76/2006-A-CN2-24.19 Rev. 0
Page 1
O I M L C e r t i f i c a t e
OIML Member State Number R76/2006-A-NL1-24.19 revision 0
The Netherlands Project number 3834855
Page 1 of 3
Issuing authority NMi Certin B.V.
Person responsible: M.Ph.D. Schmidt
Applicant and Dibal S.A.
Manufacturer Astintze Kalea, 24 - Pol. Ind. Neinver
48160 Derio, Vizcaya
Spain
Identification of the A Non-automatic weighing instrument
certified type Brand : DIBAL
Type : 500, 500-SW and D-900 Series
Characteristics See next page
This OIML Certificate is issued under scheme A.
This Certificate attests the conformity of the above identified Type (represented by the sample(s)
identified in the OIML Test Report) with the requirements of the following Recommendation of the
International Organization of Legal Metrology (OIML):
OIML R 76-1:2006 for accuracy class III or IIII
This Certificate relates only to the metrological and technical characteristics of the type of measuring
instrument covered by the relevant OIML International Recommendation above-identified.
This Certificate does not bestow any form of legal international approval.
This certificate and supporting reports comply with the requirements of OIML-CS-PD-07 clause 6.2.
Important note: Apart from the mention of the Certificate’s reference number and the name of the
OIML Member State in which the Certificate was issued, partial quotation of the Certificate and of
the associated OIML Test Report(s) is not permitted, although either may be reproduced in full.
Issuing Authority NMi Certin B.V., OIML Issuing Authority NL1
8 August 2024
Certification Board
NMi Certin B.V. This document is issued under the This document is digitally
Thijsseweg 11 provision that no liability is signed and sealed. The
2629 JA Delft accepted and that the applicant digital signature can be
The Netherlands shall indemnify third-party liability. verified in the blue
T +31 88 6362332 ribbon on top of the
certin@nmi.nl The notification of NMi Certin B.V. electronic version of this
www.nmi.nl as Issuing Authority can be verified certificate.
at www.oiml.org
Page 2
O I M L C e r t i f i c a t e
OIML Member State Number R76/2006-A-NL1-24.19 revision 0
The Netherlands Project number 3834855
Page 2 of 3
The conformity was established by the results of tests and examinations provided in the associated
reports:
Module Type Report Issue date Pages
NMi-11200653-01 30 November 2012 37
NMi-12200102-01 23 July 2012 14
500-SW NMi-12200562-01 11 December 2012 30
NMi-13200410-01 9 October 2013 17
NMi-13200410-02 9 October 2013 10
R76/2006-NL1-10.28A 26 August 2010 47
R76/2006-NL1-10.28B 26 August 2010 16
Indicator
NMi-10200492-01 21 December 2010 17
NMi-10201100-01 27 April 2011 35
500 NMi-11200395-01 22 July 2011 32
NMi-13200724-01 12 March 2014 38
NMi-15200175-01 13 April 2015 14
NMi-1901266-01 4 October 2017 12
NMi-2399743-01 21 November 2019 13
NMi-10200947-07 24 December 2020 59
L6D
NMi-10200947-08 24 December 2020 59
R60/2000-NL1-10.07 17 May 2010 40
Load cell
LAB… NMi-12200582-01 23 August 2013 52
NMi-3534839-01 29 November 2022 51
Characteristics of the non-automatic weighing instrument:
Accuracy class III or IIII
Maximum capacity 6 kg Max 30 kg
Verification scale interval e 2 g
Single interval
Weighing ranges Multi-interval
Multiple range
Maximum number of scale intervals n 3000 divisions
(Single interval)
n 3000 divisions Maximum number of scale intervals
(per weighing range or partial weighing range)
Maximum number of
2
partial weighing ranges
Load cell excitation voltage 5 V DC
Minimum input voltage per verification
1,0 µV
scale interval
Minimum load cell resistance 300
Maximum load cell resistance 900
Page 3
O I M L C e r t i f i c a t e
OIML Member State Number R76/2006-A-NL1-24.19 revision 0
The Netherlands Project number 3834855
Page 3 of 3
4-wire, or
Load cell interface
6-wire with sense technology
Maximum number of load platforms 1
Temperature range -10 °C / +40 °C
110 – 230 V AC 50/60 Hz or
Power supply voltage 12 – 24 V DC via external power supply or
internal battery
Application Intended to be used for direct sales to the public
W100 for the 500 Series;
Software identification
W200 for the 500-SW Series and D-900.
Revision History
Revision Date Change(s)
0 2024-08-07 Initial issue.