Skip to content

← R76

R76/2006-A-NL1-20.47 Rev. 2

Applicant
Xiamen Pinnacle Electrical Co.,Ltd
Issuer
NL1
Issuing year
2022
Status
Valid

Source PDF (certificates/R76/2006/r076-2006-nl1-2020-47-rev2.pdf) · extracted by OCR from the digitalized tier of the corpus.

R76/2006-A-NL1-20.47 Rev. 2

Page 1

O I M L C e r t i f i c a t e




OIML Member State                             Number R76/2006-A-NL1-20.47 revision 2
The Netherlands                                             Project number 3530489
                                                  Page 1 of 2


Issuing authority      NMi Certin B.V.
                      Person responsible: M.Ph.D. Schmidt

Applicant and        Xiamen Pinnacle Electrical Co. Ltd.
Manufacturer         4F GuangXia Building
                      Torch High-Tech Zone Xiamen
                 CN 361006 FUJIAN
                          P.R. of China

Identification of the   A Non-automatic weighing instrument
certified type         Type                            : LS2Z, LS2K, LS5, LS5K, CS5, LS4, LS4K, LS3K, LS6K, iS2,
                                                       iS3, iS4, iS5 and iS6 Series

Characteristics         See next page


This OIML Certificate is issued under scheme A.

This Certificate attests the conformity of the above identified Type (represented by the sample(s)
identified in the OIML Test Report) with the requirements of the following Recommendation of the
International Organization of Legal Metrology (OIML):

                 OIML R 76-1:2006 for accuracy class  III

This Certificate relates only to the metrological and technical characteristics of the type of measuring
instrument covered by the relevant OIML International Recommendation above-identified.
This Certificate does not bestow any form of legal international approval.

Important note: Apart from the mention of the Certificate’s reference number and the name of the
OIML Member State in which the Certificate was issued, partial quotation of the Certificate and of
the associated OIML Test Report(s) is not permitted, although either may be reproduced in full.





Issuing Authority     NMi Certin B.V., OIML Issuing Authority NL1
                     9 June 2022

                          Certification Board

NMi Certin B.V.                    This document is issued under the     This document is digitally
Thijsseweg 11                     provision that no liability is           signed and sealed. The
2629 JA Delft                   accepted and that the applicant        digital signature can be
The Netherlands                    shall indemnify third-party liability.    verified in the blue
T +31 88 6362332                                                   ribbon on top of the
certin@nmi.nl                 The notification of NMi Certin B.V.     electronic version of this
www.nmi.nl                      as Issuing Authority can be verified     certificate.
                                   at www.oiml.org

Page 2

O I M L C e r t i f i c a t e



OIML Member State                             Number R76/2006-A-NL1-20.47 revision 2
The Netherlands                                             Project number 3530489
                                                  Page 2 of 2


The conformity was established by the results of tests and examinations provided in the associated
OIML Reports:
-   No. NMi-15200660-01 dated 14 January 2016 that includes 33 pages;
-   No. NMi-15200660-02 dated 14 January 2016 that includes 47 pages;
-   No. NMi-2496179-01 dated 1 September 2020 that includes 14 pages.

Characteristics of the non-automatic weighing instrument:


 Accuracy class                                                                         III

 Maximum capacity                                     3 kg  Max  75 kg
 Verification scale interval                                    e  1 g
                                                                Single interval
 Weighing range(s)
                                                                   Multi-interval
 Maximum number of scale intervals                        n  3000
 Maximum number of
                                                            2
 partial weighing ranges
                                       T  -50% for instruments with one weighing range
 Tare
                                            T  -Max1 for multi-interval instruments
 Temperature range                                       0 °C / 40 °C
                                               13,8 V DC supplied by a 100 - 240 V AC 50/60 Hz
 Power supply voltage
                                                             adapter
                                          Intended to be used for direct sales to the public
 Application                                   Intended to be used for the making-up of
                                                          prepackages

                                                      LS2Z, LS5, CS5               V6.058

                                                  LS4X                   V7.360
 Software
                      Version number                                      V8.1XX
 identification                               LS2K, LS3K, LS4K, LS5K, LS6K
                                                                     (XX = 00… 99)

                                                                       V8.7XX
                                                             iS2, iS3, iS4, iS5, iS6
                                                                     (XX = 00… 99)

Revision History

This revision replaces the previous versions.


   Revision   Date            Changes

  0          2020-09-01           Initial issue

  1          2022-04-11      A new model range LS2K, LS5K, LS4K based on LS2Z, LS5 and LS4 is
                            added to the certificate. New models added LS3K and LS6K.

  2          2022-06-09      New models added iS2, iS3, iS4, iS5, iS6.