- Applicant
- Balancas Marques de Jose Pimenta Marques, Ltda.
- Issuer
- NL1
- Issuing year
- 2020
- Status
- Valid
R76/2006-A-NL1-20.08
Page 1
O I M L C e r t i f i c a t e
Number R76/2006-A-NL1-20.08
OIML Member State Project number 2453486
The Netherlands Page 1 of 4
Issuing authority NMi Certin B.V.
Person responsible: M. Boudewijns
Applicant and Balanças Marques de José Pimenta Marques, Lda
Manufacturer Parque Industrial de Celeirós (2° Fase), Apart. 2376
4701-905 Braga
Portugal
Identification of the A Non-automatic weighing instrument
certified type Type : PCM, TS, M, M-Air, M-WS, PVS, PVS-U, PVM, PVM-U,
PVM-Air, PLP, HS, WS, H, TLV, HW, LCM
Characteristics See next page
This OIML Certificate is issued under scheme A.
This Certificate attests the conformity of the above identified Type (represented by the sample(s)
identified in the OIML Test Report) with the requirements of the following Recommendation of the
International Organization of Legal Metrology (OIML):
OIML R 76 - Edition 2006 for accuracy class III or IIII
This Certificate relates only to the metrological and technical characteristics of the type of measuring
instrument covered by the relevant OIML International Recommendation above-identified.
This Certificate does not bestow any form of legal international approval.
Important note: Apart from the mention of the Certificate’s reference number and the name of the
OIML Member State in which the Certificate was issued, partial quotation of the Certificate and of
the associated OIML Test Report(s) is not permitted, although either may be reproduced in full.
Issuing Authority NMi Certin B.V., OIML Issuing Authority NL1
13 July 2020
Certification Board
NMi Certin B.V. This document is issued under the This document is digitally
Thijsseweg 11 provision that no liability is signed and sealed. The
2629 JA Delft accepted and that the applicant digital signature can be
The Netherlands shall indemnify third-party liability. verified in the blue
T +31 88 6362332 ribbon on top of the
certin@nmi.nl The notification of NMi Certin B.V. electronic version of this
www.nmi.nl as Issuing Authority can be verified certificate.
at www.oiml.org
Page 2
O I M L C e r t i f i c a t e
Number R76/2006-A-NL1-20.08
OIML Member State Project number 2453486
The Netherlands Page 2 of 4
The conformity was established by the results of tests and examinations provided in the associated
OIML Test Report(s):
Indicator:
- No. NMi-2283727-01 dated 15 April 2019 that includes 43 pages;
- No. NMi-2283727-02 dated 15 April 2019 that includes 22 pages;
- No. NMi-2283727-03 dated 15 April 2019 that includes 11 pages;
- No. NMi-2370113-01 dated 5 September 2019 that includes 10 pages;
- No. NMi-2370113-02 dated 5 September 2019 that includes 14 pages;
- No. NMi-2370113-03 dated 5 September 2019 that includes 17 pages.
Load cell BM:
- No. R60/2000-NL1-03.03A dated 21 January 2003 that includes 40 pages;
- No. R60/2000-NL1-03.03B dated 21 January 2003 that includes 38 pages;
- No. R60/2000-NL1-03.03A dated 21 January 2003 that includes 37 pages.
Load cell ILE-SS:
- No. NMi-11200809-02 dated 10 April 2012 that includes 27 pages.
Load cell ILEC-SS:
- No. PTB 1.12-4041659-1 dated 12 August 2009 that includes 22 pages.
Load cell MCT:
- No. NMi-15200268-01 rev.1 dated 29 September 2015 that includes 51 pages.
Load cell MLC 1A / MLC 1A MG:
- No. NMi-11200434-01 dated 26 November 2010 that includes 25 pages;
- No. NMi-11200434-02 dated 26 November 2010 that includes 27 pages.
Load cell SB:
- No. LXff2003-6002 dated 2 April 2003 that includes 18 pages.
Load cell UDA:
- No.1.12-4040888-1 dated 23 June 2009 that includes 22 pages.
Characteristics of the non-automatic weighing instrument:
Accuracy class III or IIII
Maximum capacity Depending on the load cell(s) used
Verification scale interval Depending on the load cell(s) used
Temperature range 0 °C / +40 °C
The compatibility of load cells and indicator is established by the manufacturer by means of the
compatibility of modules form, contained in OIML R 76 (2006) Annex F clause F.4, at the time of
putting into use.
Page 3
O I M L C e r t i f i c a t e
Number R76/2006-A-NL1-20.08
OIML Member State Project number 2453486
The Netherlands Page 3 of 4
Characteristics of the indicator:
Accuracy class III
Single interval
Weighing range(s)
Multi-interval
Maximum number of scale intervals
n 6000 (one weighing range)
Maximum number of scale intervals n 3000
(multi-interval) (per partial weighing range)
Maximum number of
2
partial weighing ranges
Load cell excitation voltage 5 V DC
Minimum signal input voltage Umin = 0 mV
Minimum input voltage per verification
0,3 µV
scale interval
Minimum load cell resistance 44
Maximum load cell resistance 1050
Fraction of the maximum permissible error 0,5
Load cell connection 6-wire (remote sensing)
Maximum value of the cable length per
cross wire section between the indicator and 1463,7 m/mm2
the junction box or load cells
Maximum number of load platforms 2
temperature range 0 °C / +40 °C
Climatic
humidity non-condensing
environment
intended location Closed
Electromagnetic environment class E2
230 V AC 50/60 Hz or
Power supply voltage
12 V DC by AC/DC adapter
V-1.xx
Version number:
Software (xx is a number between 00 and 99)
identification
Checksum: 0bAdA3dC
Page 4
O I M L C e r t i f i c a t e
Number R76/2006-A-NL1-20.08
OIML Member State Project number 2453486
The Netherlands Page 4 of 4
Characteristics of the load cells:
See OIML certificates:
- BM: R60/2000-NL1-03.03, dated 21 January 2003 that includes 2 pages;
- ILE-SS: R60/2000-NL1-12.04, dated 10 April 2012 that includes 2 pages;
- ILEC-SS: R60/2000-DE1-09.10, dated 13 August 2009 that includes 2 pages;
- MC-CT: R60/2000-A-NL1-18.26, dated 19 November 2018 that includes 2 pages;
- MLC 1A / MLC 1A MG: R60/2000-NL1-15.04, dated 19 March 2015 that includes 2 pages;
- SB: R60/2000-CN-03.03, dated 14 May 2003 that includes 3 pages;
- UDA: R60/2000-DE1-09.17, dated 23 July 2009 that includes 2 pages.