Skip to content

← R76

R76/2006-A-NL1-19.56 Rev. 1

Applicant
Rice Lake Weighing Systems
Issuer
NL1
Issuing year
2019
Status
Valid

Source PDF (certificates/R76/2006/r076-2006-nl1-2019-56-rev1.pdf) · extracted by OCR from the digitalized tier of the corpus.

R76/2006-A-NL1-19.56 Rev. 1

Page 1

O I M L C e r t i f i c a t e



                                           Number R76/2006-A-NL1-19.56 Revision 1
                                                           Project number 2433604
OIML Member State                             Page 1 of 2
The Netherlands


Issuing authority      NMi Certin B.V.
                      Person responsible: F. van Booma–de Smit

Applicant and          Rice Lake Weighing Systems
Manufacturer         230 West Coleman Street
                        Rice Lake, WI 54868
                      United States of America



Identification of the   An Indicator
certified type         Type                                                        :  680 Plus-2A

Characteristics         See next page


This OIML Certificate is issued under scheme A.

This Certificate attests the conformity of the above identified Type (represented by the sample(s)
identified in the OIML Test Report) with the requirements of the following Recommendation of the
International Organization of Legal Metrology (OIML):

                 OIML R 76 - Edition 2006 for accuracy class  III  or  IIII

This Certificate relates only to the metrological and technical characteristics of the type of measuring
instrument covered by the relevant OIML International Recommendation above-identified.
This Certificate does not bestow any form of legal international approval.

Important note: Apart from the mention of the Certificate’s reference number and the name of the
OIML Member State in which the Certificate was issued, partial quotation of the Certificate and of
the associated OIML Test Report(s) is not permitted, although either may be reproduced in full.





Issuing Authority     NMi Certin B.V., OIML Issuing Authority NL1
                     22 November 2019

                          Certification Board

NMi Certin B.V.                    This document is issued under the     This document is digitally
Thijsseweg 11                     provision that no liability is           signed and sealed. The
2629 JA Delft                   accepted and that the applicant        digital signature can be
The Netherlands                    shall indemnify third-party liability.    verified in the blue
T +31 88 6362332                                                   ribbon at the top of the
certin@nmi.nl                 The notification of NMi Certin B.V.     electronic version of this
www.nmi.nl                       as Issuing Authority can be verified     certificate.
                                   at www.oiml.org

Page 2

O I M L C e r t i f i c a t e


                                             Number R76/2006-A-NL1-19.56 Revision 1
                                                              Project number 2433604
OIML Member State                                Page 2 of 2
The Netherlands


The conformity was established by the results of tests and examinations provided in the associated
OIML Type Evaluation Report:
-   No. NMi-2343404-01 dated 1 November 2019 that includes 51 pages.

Characteristics of the indicator:

 Configuration                                         Analog load cells

 Accuracy class                                                                            III  or  IIII
 Weighing range(s)                                              Single interval
 Maximum number of scale intervals                         n  10000
 Load cell excitation voltage                                   10 V DC
 Minimum signal input voltage                                      Umin = 0 mV
 Minimum input voltage per verification
                                                            1 µV
 scale interval
 Minimum load cell resistance                                   43 
 Maximum load cell resistance                                 1050 
 Fraction of the maximum permissible error                             0,5
                                                                  4-wire or
 Load cell connection
                                                           6-wire (remote sensing)
                                                             1320,4 m/mm2
 Maximum value of the cable length per
                                                    (No special cable length)
 cross wire section between the indicator and
                                                    In case a 4-wire connection is used the load cells
 the junction box or load cells
                                                 are connected directly without junction box
 Temperature range                                             -10 °C / +40 °C

 Power supply voltage                                  100– 240 V AC 50/60 Hz
 Software identification                                  Version number: v 1.00.xx



Revision History

This revision replaces the previous version(s).


   Revision   Date              Change(s)

      Initial    01-11-2019            -

      1      22-11-2019        Correction Software version