Skip to content

← R76

R76/2006-A-NL1-19.36 Rev. 1

Applicant
Hottinger Baldwin Messtechnik GmbH
Issuer
NL1
Issuing year
2022
Status
Valid

Source PDF (certificates/R76/2006/r076-2006-nl1-2019-36-rev1.pdf) · extracted by OCR from the digitalized tier of the corpus.

R76/2006-A-NL1-19.36 Rev. 1

Page 1

O I M L C e r t i f i c a t e



                                              Number R76/2006-A-NL1-19.36 Revision 1
OIML Member State                                        Project number 2623826
The Netherlands                                     Page 1 of 2


Issuing authority     NMi Certin B.V.
                      Person responsible: M.Ph.D. Schmidt

Applicant and         Hottinger Brüel & Kjaer GmbH
Manufacturer        Im Tiefen See 45
                     D-64293 Darmstadt
                   Germany

Identification of the   An Analog data processing device (ADPD)
certified type         Type                 : PAD-400xA

Characteristics         See next page


This OIML Certificate is issued under scheme A.

This Certificate attests the conformity of the above identified Type (represented by the sample(s)
identified in the OIML Test Report) with the requirements of the following Recommendation of the
International Organization of Legal Metrology (OIML):

                 OIML R 76 - Edition 2006 for accuracy class  III  or  IIII

This Certificate relates only to the metrological and technical characteristics of the type of measuring
instrument covered by the relevant OIML International Recommendation above-identified.
This Certificate does not bestow any form of legal international approval.

Important note: Apart from the mention of the Certificate’s reference number and the name of the
OIML Member State in which the Certificate was issued, partial quotation of the Certificate and of
the associated OIML Test Report(s) is not permitted, although either may be reproduced in full.





Issuing Authority     NMi Certin B.V., OIML Issuing Authority NL1
                    31 March 2022

                          Certification Board

NMi Certin B.V.                    This document is issued under the     This document is digitally
Thijsseweg 11                     provision that no liability is           signed and sealed. The
2629 JA Delft                   accepted and that the applicant        digital signature can be
The Netherlands                     shall indemnify third-party liability.    verified in the blue
T +31 88 6362332                                                   ribbon on top of the
certin@nmi.nl                 The notification of NMi Certin B.V.     electronic version of this
www.nmi.nl                       as Issuing Authority can be verified     certificate.
                                   at www.oiml.org

Page 2

O I M L C e r t i f i c a t e


                                         Number R76/2006-A-NL1-19.36 Revision 1
OIML Member State                                  Project number 2623826
The Netherlands                                Page 2 of 2


The conformity was established by the results of tests and examinations provided in the associated
OIML Reports:
-   No. NMi-14200646-01 dated 13 June 2016 that includes 43 pages;
-   No. NMi-14200646-02 dated 13 June 2016 that includes 17 pages;
-   No. NMi-2623826-02 dated 31 March 2022 that includes 8 pages.

Characteristics of the indicator:

 Configuration                                              Analog load cells

 Accuracy class                                                                            III  or IIII

                                                                       Single interval
 Weighing range(s)
                                                                    Multiple range
 Maximum number of scale intervals
                                                         n  6000 (one weighing range)
 Maximum number of scale intervals
                                                n  3000 (per weighing range) (multiple range)
 Maximum number of weighing ranges                                2
 Load cell excitation voltage                                  5 V AC square wave
 Minimum input voltage per verification scale interval                      0,5 µV
 Minimum load cell resistance                                       300 
 Maximum load cell resistance                                       900 
 Load cell interface                                                     4-wire
 Maximum value of the cable length per cross wire
 section between the ADPD and the junction box or                     3 m
 load cells
                     temperature range                             -10 °C / +40 °C Climatic
 environment                     humidity                                  non-condensing

 Electromagnetic environment class                                   E2
 Power supply voltage                                          12 – 30 V DC
                                                        Version number: 80, Checksum: 240413
 Software identification                                                 or
                                                        Version number: 81, Checksum: 244554

Revision History

This revision replaces the previous version.


   Revision     Date            Change(s)

   Initial       2019-07-09          -

  1            2022-03-31     Added software version