Skip to content

← R76

R76/2006-A-NL1-18.23

Applicant
Rice Lake Weighing Systems
Issuer
NL1
Issuing year
2018
Status
Valid

Source PDF (certificates/R76/2006/r076-2006-nl1-2018-23.pdf) · extracted by OCR from the digitalized tier of the corpus.

R76/2006-A-NL1-18.23

Page 1

O I M L C e r t i f i c a t e



          OIML Member State                                     Number R76/2006-A-NL1-18.23
           The Netherlands                                                        Project number 1902470
                                                                      Page 1 of 2


              Issuing authority      NMi Certin B.V.
                                  Person responsible: C. Oosterman

             Applicant and          Rice Lake Weighing Systems
            Manufacturer         230 West Coleman Street
                                      Rice Lake, WI54868
                                  United States of America

              Identification of the   An Indicator
               certified type         Type                                                        :  880-2A, 880-2D, 880-3A, 880-3D

               Characteristics         See next page


              This OIML Certificate is issued under scheme A.

              This Certificate attests the conformity of the above identified Type (represented by the sample(s)
              identified in the OIML Test Report) with the requirements of the following Recommendation of the
              International Organization of Legal Metrology (OIML):

                           OIML R 76 - Edition 2006 for accuracy class  III  or  IIII

              This Certificate relates only to the metrological and technical characteristics of the type of measuring
             instrument covered by the relevant OIML International Recommendation above-identified.
              This Certificate does not bestow any form of legal international approval.

            Important note: Apart from the mention of the Certificate’s reference number and the name of the
          OIML Member State in which the Certificate was issued, partial quotation of the Certificate and of
            the associated OIML Test Report(s) is not permitted, although either may be reproduced in full.





              Issuing Authority     NMi Certin B.V., OIML Issuing Authority NL1
                                17 May 2018




                                        C. Oosterman
                             Head Certification Board

              NMi Certin B.V.                    This document is issued under the
              Hugo de Grootplein 1             provision that no liability is
                 3314 EG Dordrecht              accepted and that the applicant
                  the Netherlands                    shall indemnify third-party liability.
                 T +31 78 6332332
                   certin@nmi.nl                 The notification of NMi Certin B.V.
                www.nmi.nl                       as Issuing Authority can be verified
                                                      at www.oiml.org


101

Page 2

O I M L C e r t i f i c a t e


          OIML Member State                                     Number R76/2006-A-NL1-18.23
           The Netherlands                                                        Project number 1902470
                                                                      Page 2 of 2


           The conformity was established by the results of tests and examinations provided in the associated
          OIML Test Reports:
                   -   No. NMi-13200624-01 dated 13 June 2014 that includes 50 pages;
                   -   No. NMi-13200624-02 dated 26 June 2014 that includes 8 pages.

             Characteristics of the indicator:

              Configuration                                          Analog load cells

              Accuracy class       OIML R 76                                                 III  or  IIII

                                                                                Single interval
            Weighing range(s)                                                 Multi-interval
                                                                             Multiple range
           Maximum number of scale intervals
                                                             n  10000 divisions             (one weighing range)
           Maximum number of scale intervals                      n  10000 divisions
                (multi-interval)                                            (per partial weighing range)
           Maximum number of
                                                                          2
                partial weighing ranges
           Maximum number of scale intervals                      n  10000 divisions
               (multiple range)                                              (per weighing range)
           Maximum number of weighing ranges                             2
            Load cell excitation voltage                                   10 V DC
           Minimum input voltage                                              Umin = 0 mV
           Minimum input voltage per verification
                                                                         1 µV
                scale interval
           Minimum load cell resistance                                   21 
           Maximum load cell resistance                                  1050 
               Fraction of the maximum permissible error                              0,5
            Load cell connection                                       6-wire (remote sensing)
           Maximum value of the cable length per                No special cable length
                cross wire section between the indicator and   In case a 4-wire connection is used the load cells are
              the junction box or load cells                     connected directly without junction box
             Temperature range                                              -10 °C / +40 °C

                                                                100 – 240 V AC 50/60 Hz
            Power supply voltage                                       9 – 36 V DC
                                                               (not suitable for a road vehicle power supply)
                                                                         Version number: 1.xx
             Software identification                                  (xx is a number between 00 and 99)
                                                                                (1. represents the legally relevant software)