- Applicant
- Laumas Elettronica S.r.l.
- Issuer
- GB1
- Issuing year
- 2022
- Status
- Valid
R76/2006-A-GB1-22.01
Page 1
OIML Member State OIML Certificate No.
United Kingdom of Great Britain R76/2006-A-GB1-22.01
and Northern Ireland
OIML CERTIFICATE ISSUED UNDER SCHEME A
OIML Issuing Authority Office for Product Safety and Standards
Stanton Avenue
Teddington
TW11 0JZ
United Kingdom
Person responsible: Mannie Panesar
Applicant LAUMAS Elettronica S.R.L.
VIA Primo Maggio 6
43022 Montechiarugolo (PR)
Italy
Manufacturer The applicant
Identification of the W series
certified type (the detailed characteristics are defined in the Descriptive Annex)
This OIML Certificate attests the conformity of the above identified type (represented by the
sample(s) identified in the OIML type evaluation report) with the requirements of the following
Recommendation of the International Organization of Legal Metrology (OIML):
OIML R 76-1, Edition: 2006
For accuracy class: III and IIII
Issue date: 10 May 2022
The OIML Issuing Authority
Marek Bokota
Technical Manager
For and on behalf of the Office for Product Safety and Standards
Office for Product Safety and Standards I Stanton Avenue I Teddington I TW11 0JZ I United Kingdom
Tel +44 (0) 20 8943 7272 I Web www.gov.uk/government/organisations/office-for-product-safety-and-standards
The Office for Product Safety and Standards is part of the Department for Business, Energy & Industrial Strategy
Page 2
OIML Certificate No.
R76/2006-A-GB1-22.01
This OIML Certificate relates only to metrological and technical characteristics of the type of
measuring instrument covered by the relevant OIML Recommendation identified above.
This OIML Certificate does not bestow any form of legal international approval.
The conformity was established by the results of tests and examinations provided in the
associated OIML type evaluation report:
No. P02980 dated 10 May 2022 that includes 16 pages
The technical documentation relating to the identified type is contained in documentation file:
No. P02980-D dated 10 May 2022
OIML Certificate History
Revision No. Date Description of the modification
0 10 May 2022 Certificate first issued.
- - -
No revisions have been issued.
Important note:
Apart from the mention of the Certificate’s reference number and the name of the OIML
Member State in which the Certificate is issued, partial quotation of the Certificate and of the
associated OIML type evaluation report(s) is not permitted, although either may be
reproduced in full.
Page 2 of 5 pages
Page 3
OIML Certificate No.
R76/2006-A-GB1-22.01
DESCRIPTIVE ANNEX
Characteristics of the instrument:
This family of indicating devices comprises the W100 / W200 / W200IP64 / W200IP67 / WDOS /
WDESK / WDESKLIGHT / WINOX / WTAB / W200BOX / W200BOXEC / ADPEW200 /
WLIGHT models. The indicators are self-indicating, mains, DC or battery-powered, and are de-
signed to be used as part of Class III or IIII, single or multi-interval, or multi-range, non-
automatic weighing instruments.
The above designations may have the prefix “JOLLY” and may be followed by alphanumeric
characters (e.g. JOLLY WINOXL).
The WDOS (special version), WDESK, WINOX and WTAB indicators with LCD display may be
used for direct sales to the public.
Main features:
− Metal or plastic enclosure
− LCD or LED display
− Operator’s keypad with 4 to 62 keys
− Optional secondary display
− Optional level indicator based on a digital input
− Connection through shunt-diode safety barrier (EEx version)
Devices:
− Initial zero setting device (< 20% of Max)
− Semi-automatic zero setting device (< 4% of Max)
− Zero tracking device (< 4% of Max)
− Semi-automatic tare weighing or balancing
− Preset tare (not for direct sales for public)
− Display check at power-up
− Alibi memory
− Gravity compensation
− Extended indication (not available to the user)
− Printing
− Price computing
− Stable weight indicator
− Weighing unstable samples (optional)
− Real time clock
− Operator information messages
Price computing models:
The WDOS (special version), WDESK, WINOX and WTAB models can operate as a price
computing instruments with a price look-up table. Selection of product and price are per-
formed via a digital input or serial interface.
Page 3 of 5 pages
Page 4
OIML Certificate No.
R76/2006-A-GB1-22.01
Technical data:
W series not including EEx EEx version
Type: W100 / W200 / W200IP64 / W100 / W200 / W200IP64 /
W200IP67 / WDOS / W200IP67 / WDOS /
WDESK / WDESKLIGHT / WDESK / WDESK-LIGHT /
WINOX / WTAB / WINOX / WTAB /
W200BOX / W200BOXEC / W200BOX / W200BOXEC /
ADPEW200 / WLIGHT ADPEW200 / WLIGHT
Accuracy class: III or IIII III or IIII
Weighing range: Single-interval, multi-range Single-interval, dual-range
or multi-interval (2 or 3) or dual-interval
Maximum number of verifica- 10000 for Class III 7500 for Class III
tion scale intervals (n): 1000 for Class IIII 1000 for Class IIII
Minimum input voltage per 0.2 μV 0.52 μV
VSI:
Maximum capacity of interval ni × ei ni × ei
or range (Maxi):
Verification scale interval, ei = Maxi/ni ei = Maxi/ni
Initial zero-setting range: ± 10 % of Max ± 10 % of Max
Maximum tare effect: 100 % of Max 100 % of Max
Fractional factor (pi): 0.5 0.5
Excitation voltage: 5 VDC 5 VDC
Minimum input impedance: 43 ohm 43 ohm
Maximum input impedance: 1200 ohm 1200 ohm
Connecting cable to load 4-wire or 6-wire system 4-wire or 6-wire system
cell(s):
Supply voltage: 12 - 24 VDC, or 230 VAC 12 - 24 VDC, or 230 VAC
Operating temperature range -10 °C to +40 °C -10 °C to +40 °C
Shunt-diode safety barrier N/A MTL7761ac, MTL7766Pac,
or similar
Load cell:
Any compatible load cell(s) may be used providing the following conditions are met:
− There is a respective OIML Certificate of Conformity (R60) issued for the load cell.
− The certificate contains the load cell types and the necessary load cell data required
for the manufacturer’s declaration of compatibility of modules (R76-1 (2006), Annex
F), and any particular installation requirements. A load cell marked NH is allowed
only if humidity testing to R76 has been conducted on this load cell.
− The compatibility of the load cells and indicator is established by the manufacturer
by means of the compatibility of modules calculation at the time of verification.
− The load cell transmission must conform to one of the examples shown in OIML
R60: 2017 – Annex E.
The instruments may be connected to the following digital load cells:
Manufacturer Load cell designation OIML Certificate number
Laumas Electronica S.r.L COKD…, COD… R60/2000-A-NL1-21.44
Keli Sensing Technology ZSF-D, ZSF-DSS, ZSW-D, R60/2000-NL1-13.25
(Ningbo) Co. Ltd. ZSW-DSS
Page 4 of 5 pages
Page 5
OIML Certificate No.
R76/2006-A-GB1-22.01
Interfaces:
The instruments may have any of the following protected interface type:
− Load cell 4-wire or 6-wire shielded connection
− RS232C
− RS485
− USB
− Modbus RTU, Profibus, DeviceNet and CANopen Ethernet TCP/IP, Ethernet/IP,
Modbus/TCP, Profinet IO, EtherCAT, POWERLINK, SERCOSIII, CC-link, CC-link IE
and IO-link
− Digital output / Digital input
− Analogue input / Analogue output
− Wireless
Software:
The software version number is displayed at power up.
The version format is xx.yy.zz, where xx is the legally relevant version number, with yy and
zz the major and minor version numbers reflecting non-legally relevant changes.
The software version for standard indicators is 01.yy.zz, where yy.zz shall be 00.46 or
higher. The software version for price computing indicators is 01.yy.zz, where yy.zz shall be
03.04 or higher.
Sealing:
The calibration and legally relevant parameters are protected via physical or software means.
The indicators have an event counter, which increments each time the legally relevant
parameters (calibration and configuration) are changed. The value of the event counter can
be displayed in the ‘Menu’ under ‘Info’, and must be written on the data plate.
For the WLIGHT indicator the legally relevant parameters (calibration and configuration) can
be accessed by pressing a button on the rear of the indicator. This button is protected by
tamper evident seals.
Access to the electronics, jumper, load cell connections, junction box, and peripheral interfaces
is prevented via tamper evident labels or by the use of wire and seals.
Alternatively, the electonics may be secured via a tamper evident label on the cover protecting
the analogue circuits, swapping of the electonics is then prevented via a common indicator
serial number (affixed on on the data plate and displayed from the the non-erasable memory).
Alternatively, the indicator and load receptor with load cell made be secured via common serial
numbers (indicator serial number on platform or load cell serial number on indicator).
This is not necessary for the W200IP64, W200IP67, WDESK, WDESKLIGHT, WINOX,
W200BOX, W200BOXEC and ADPEW200 models with hardwired load cell connection,
provided the indicator enclosure is sealed.
Page 5 of 5 pages