Skip to content

← R76

R76/2006-A-GB1-22.01

Applicant
Laumas Elettronica S.r.l.
Issuer
GB1
Issuing year
2022
Status
Valid

Source PDF (certificates/R76/2006/r076-2006-gb1-2022-01.pdf) · extracted by OCR from the digitalized tier of the corpus.

R76/2006-A-GB1-22.01

Page 1

OIML Member State                                    OIML Certificate No.
United Kingdom of Great Britain                               R76/2006-A-GB1-22.01
and Northern Ireland
               OIML CERTIFICATE ISSUED UNDER SCHEME A

OIML Issuing Authority  Office for Product Safety and Standards
                     Stanton Avenue
                    Teddington
                TW11 0JZ
                     United Kingdom
Person responsible:    Mannie Panesar

Applicant          LAUMAS Elettronica S.R.L.
                    VIA Primo Maggio 6
                    43022 Montechiarugolo (PR)
                           Italy

Manufacturer         The applicant

Identification of the   W series
certified type            (the detailed characteristics are defined in the Descriptive Annex)

This OIML Certificate attests the conformity of the above identified type (represented by the
sample(s) identified in the OIML type evaluation report) with the requirements of the following
Recommendation of the International Organization of Legal Metrology (OIML):

OIML R 76-1, Edition: 2006

For accuracy class: III and IIII

Issue date: 10 May 2022

The OIML Issuing Authority



Marek Bokota
Technical Manager
For and on behalf of the Office for Product Safety and Standards





                      Office for Product Safety and Standards I Stanton Avenue I Teddington I TW11 0JZ I United Kingdom
                 Tel +44 (0) 20 8943 7272 I Web www.gov.uk/government/organisations/office-for-product-safety-and-standards
             The Office for Product Safety and Standards is part of the Department for Business, Energy & Industrial Strategy

Page 2

OIML Certificate No.
                                                          R76/2006-A-GB1-22.01

This OIML Certificate relates only to metrological and technical characteristics of the type of
measuring instrument covered by the relevant OIML Recommendation identified above.

This OIML Certificate does not bestow any form of legal international approval.

The conformity was established by the results of tests and examinations provided in the
associated OIML type evaluation report:
No. P02980 dated 10 May 2022 that includes 16 pages

The technical documentation relating to the identified type is contained in documentation file:
No. P02980-D dated 10 May 2022

OIML Certificate History
Revision No.   Date                Description of the modification
0             10 May 2022           Certificate first issued.
-                      -                              -
No revisions have been issued.

Important note:
Apart from the mention of the Certificate’s reference number and the name of the OIML
Member State in which the Certificate is issued, partial quotation of the Certificate and of the
associated OIML type evaluation report(s) is not permitted, although either may be
reproduced in full.





                                Page 2 of 5 pages

Page 3

OIML Certificate No.
                                                          R76/2006-A-GB1-22.01


DESCRIPTIVE ANNEX
Characteristics of the instrument:

This family of indicating devices comprises the W100 / W200 / W200IP64 / W200IP67 / WDOS /
WDESK  / WDESKLIGHT  / WINOX  / WTAB  / W200BOX  / W200BOXEC  / ADPEW200  /
WLIGHT models. The indicators are self-indicating, mains, DC or battery-powered, and are de-
signed to be used as part of Class  III or  IIII, single or multi-interval, or multi-range, non-
automatic weighing instruments.

The above designations may have the prefix “JOLLY” and may be followed by alphanumeric
characters (e.g. JOLLY WINOXL).

The WDOS (special version), WDESK, WINOX and WTAB indicators with LCD display may be
used for direct sales to the public.

Main features:

    −  Metal or plastic enclosure
    −  LCD or LED display
    −  Operator’s keypad with 4 to 62 keys
    −  Optional secondary display
    −  Optional level indicator based on a digital input
    −  Connection through shunt-diode safety barrier (EEx version)

Devices:

    −   Initial zero setting device (< 20% of Max)
    −  Semi-automatic zero setting device (< 4% of Max)
    −  Zero tracking device (< 4% of Max)
    −  Semi-automatic tare weighing or balancing
    −  Preset tare (not for direct sales for public)
    −  Display check at power-up
    −   Alibi memory
    −  Gravity compensation
    −  Extended indication (not available to the user)
    −  Printing
    −  Price computing
    −  Stable weight indicator
    −  Weighing unstable samples (optional)
    −  Real time clock
    −  Operator information messages

Price computing models:

The WDOS (special version), WDESK, WINOX and WTAB models can operate as a price
computing instruments with a price look-up table. Selection of product and price are per-
formed via a digital input or serial interface.





                                Page 3 of 5 pages

Page 4

OIML Certificate No.
                                                          R76/2006-A-GB1-22.01

Technical data:

                W series not including EEx   EEx version
 Type:                  W100 / W200 / W200IP64 /  W100 / W200 / W200IP64 /
                          W200IP67 / WDOS /       W200IP67 / WDOS /
                    WDESK / WDESKLIGHT /  WDESK / WDESK-LIGHT /
                      WINOX / WTAB /        WINOX / WTAB /
                      W200BOX / W200BOXEC /  W200BOX / W200BOXEC /
                      ADPEW200 / WLIGHT     ADPEW200 / WLIGHT
 Accuracy class:                           III or IIII                                    III or IIII
 Weighing range:                 Single-interval, multi-range    Single-interval, dual-range
                                  or multi-interval (2 or 3)       or dual-interval
 Maximum number of verifica-   10000 for Class III         7500 for Class III
 tion scale intervals (n):        1000 for Class IIII          1000 for Class IIII
 Minimum input voltage per      0.2 μV                     0.52 μV
 VSI:
 Maximum capacity of interval    ni × ei                               ni × ei
 or range (Maxi):
 Verification scale interval,         ei = Maxi/ni                         ei = Maxi/ni
 Initial zero-setting range:      ± 10 % of Max             ± 10 % of Max
 Maximum tare effect:         100 % of Max             100 % of Max
 Fractional factor (pi):           0.5                          0.5
 Excitation voltage:           5 VDC                   5 VDC
 Minimum input impedance:    43 ohm                  43 ohm
 Maximum input impedance:    1200 ohm                1200 ohm
 Connecting cable to load        4-wire or 6-wire system       4-wire or 6-wire system
 cell(s):
 Supply voltage:              12 - 24 VDC, or 230 VAC    12 - 24 VDC, or 230 VAC
 Operating temperature range   -10 °C to +40 °C             -10 °C to +40 °C
 Shunt-diode safety barrier     N/A                     MTL7761ac, MTL7766Pac,
                                                                or similar

Load cell:

Any compatible load cell(s) may be used providing the following conditions are met:
    −  There is a respective OIML Certificate of Conformity (R60) issued for the load cell.
    −  The certificate contains the load cell types and the necessary load cell data required
          for the manufacturer’s declaration of compatibility of modules (R76-1 (2006), Annex
          F), and any particular installation requirements. A load cell marked NH is allowed
         only if humidity testing to R76 has been conducted on this load cell.
    −  The compatibility of the load cells and indicator is established by the manufacturer
       by means of the compatibility of modules calculation at the time of verification.
    −  The load cell transmission must conform to one of the examples shown in OIML
       R60: 2017 – Annex E.

The instruments may be connected to the following digital load cells:

 Manufacturer              Load cell designation      OIML Certificate number
 Laumas Electronica S.r.L    COKD…, COD…           R60/2000-A-NL1-21.44
 Keli Sensing Technology     ZSF-D, ZSF-DSS, ZSW-D,  R60/2000-NL1-13.25
 (Ningbo) Co. Ltd.          ZSW-DSS


                                Page 4 of 5 pages

Page 5

OIML Certificate No.
                                                          R76/2006-A-GB1-22.01

Interfaces:

The instruments may have any of the following protected interface type:

    −  Load cell 4-wire or 6-wire shielded connection
    −  RS232C
    −  RS485
    −  USB
    −  Modbus RTU, Profibus, DeviceNet and CANopen Ethernet TCP/IP, Ethernet/IP,
       Modbus/TCP, Profinet IO, EtherCAT, POWERLINK, SERCOSIII, CC-link, CC-link IE
       and IO-link
    −   Digital output / Digital input
    −  Analogue input / Analogue output
    −  Wireless

Software:

The software version number is displayed at power up.

The version format is xx.yy.zz, where xx is the legally relevant version number, with yy and
zz the major and minor version numbers reflecting non-legally relevant changes.

The software version for standard indicators is 01.yy.zz, where yy.zz shall be 00.46 or
higher. The software version for price computing indicators is 01.yy.zz, where yy.zz shall be
03.04 or higher.

Sealing:

The calibration and legally relevant parameters are protected via physical or software means.

The indicators have an event counter, which increments each time the legally relevant
parameters (calibration and configuration) are changed. The value of the event counter can
be displayed in the ‘Menu’ under ‘Info’, and must be written on the data plate.

For the WLIGHT indicator the legally relevant parameters (calibration and configuration) can
be accessed by pressing a button on the rear of the indicator. This button is protected by
tamper evident seals.

Access to the electronics, jumper, load cell connections, junction box, and peripheral interfaces
is prevented via tamper evident labels or by the use of wire and seals.

Alternatively, the electonics may be secured via a tamper evident label on the cover protecting
the analogue circuits, swapping of the electonics is then prevented via a common indicator
serial number (affixed on on the data plate and displayed from the the non-erasable memory).

Alternatively, the indicator and load receptor with load cell made be secured via common serial
numbers (indicator serial number on platform or load cell serial number on indicator).

This  is not necessary  for the W200IP64, W200IP67, WDESK, WDESKLIGHT, WINOX,
W200BOX, W200BOXEC and ADPEW200 models  with hardwired load  cell connection,
provided the indicator enclosure is sealed.




                                Page 5 of 5 pages