Skip to content

← R76

R76/2006-A-GB1-18.02 Rev. 1

Applicant
Xiamen Balance Electronic Technology Co., Ltd
Issuer
GB1
Issuing year
2019
Status
Valid

Source PDF (certificates/R76/2006/r076-2006-gb1-2018-02-rev1.pdf) · extracted by OCR from the digitalized tier of the corpus.

R76/2006-A-GB1-18.02 Rev. 1

Page 1

OIML Member State                                    OIML Certificate No.
United Kingdom of Great Britain                               R76/2006-A-GB1-18.02
and Northern Ireland                                                    Revision 1

               OIML CERTIFICATE ISSUED UNDER SCHEME A

OIML Issuing Authority NMO
                     Stanton Avenue
                    Teddington
                 TW11 0JZ
                     United Kingdom

Person responsible:    Mannie Panesar – Head of Technical Services

Applicant            Xiamen Balance Electronic Technology Co., Ltd.
                Room 1001-1, No.15-16, Tongan Industrial Park
                      Meixi Road, Tongan District
                   Xiamen
                PR China

Manufacturer         The applicant

Identification of the    B Series (BPS, BRS and BLS models)
certified type            (the characteristics are defined in the Descriptive Annex)

This OIML Certificate attests the conformity of the above identified type (represented by the
sample(s) identified in the OIML type evaluation report) with the requirements of the following
Recommendation of the International Organization of Legal Metrology (OIML):

OIML R 76-1, Edition: 2006

For accuracy class: III



The OIML Issuing Authority

Issue date: 24 January 2019





G Stones
Technical Manager
For and on behalf of the Head of Technical Services




                        NMO I Stanton Avenue I Teddington I TW11 OJZ I United Kingdom
    Tel +44 (0) 20 8943 7272 I Fax +44 (0) 20 8943 7270 I Web www.gov.uk/government/organisations/office-for-product-safety-and-standards
      NMO is part of the Office for Product Safety and Standards within the Department for Business, Energy & Industrial Strategy

Page 2

OIML Certificate No.
                                                          R76/2006-A-GB1-18.02
                                                                      Revision 1


This OIML Certificate relates only to metrological and technical characteristics of the type of
measuring instrument covered by the relevant OIML Recommendation identified above.

This OIML Certificate does not bestow any form of legal international approval.

The conformity was established by the results of tests and examinations provided in the
associated OIML type evaluation report:

No. P02123 dated 02 March 2018 that includes 16 pages

The technical documentation relating to the identified type is contained in documentation file:

No. P02123-D dated 02 March 2018

OIML Certificate History

Revision No.   Date                Description of the modification
Revision 0     02 March 2018         Certificate first issued.
Revision 1     24 January 2019      Correction to description of characteristics, and
                                          addition of Technical data, for the instrument.

.


Important note:
Apart from the mention of the Certificate’s reference number and the name of the OIML
Member State in which the Certificate is issued, partial quotation of the Certificate and of the
associated OIML type evaluation report(s) is not permitted, although either may be
reproduced in full.





                                Page 2 of 5 pages

Page 3

OIML Certificate No.
                                                          R76/2006-A-GB1-18.02
                                                                      Revision 1

DESCRIPTIVE ANNEX

Characteristics of the instrument:
The B Series comprises a BPS indicator (model) connected to a range of load cells to form a
family of Class  III, mains or battery-operated, self-indicating, single or dual-interval, non-
automatic weighing instruments. The BPS indicator may be designated as the BPS and their
variants, BRS and BLS models depending upon the construction.

        Max    ≤      30 kg
          Min    ≥      40 g
         e      ≥      2 g
         n      ≤      6000 (for single-interval)
             ni      ≤      3000 (for dual-interval)

The instrument may be used for direct sales to the public.


Model variants and designation:


 Model  Display   Variant designation    Options            Remarks
                   BPS-A, BPS-A3
                   BPS-B, BPS-B3      RS232      Integral front and rear displays.
                   BPS-X, BPS-X3
        LCD     BPS-A1, BPS-A4
                                                                Integral front display and pole-
 BPS      or      BPS-B1, BPS-B4      RS232
                                                mounted rear display.
        LED     BPS-X1, BPS-X4
                  BPS-A2, BPS-A5
                                                    Pole-mounted  front and  rear
                  BPS-B2, BPS-B5      RS232
                                                              displays.
                  BPS-X2, BPS-X5

                                   RS232     Pole-mounted  front and  rear
 BRS   LCD                  ----           USB       displays.
                                              Ethernet     Integral printer.

                                   RS232     Pole-mounted  front and  rear
  BLS   LCD                  ----           USB       displays.
                                              Ethernet     Integral printer.

Construction:

      −  Plastic enclosure
      −  Plastic / Stainless Steel load receptor
      −  Dual, integral or pole-mounted, LCD/LED display
      −  Operator keypad
      −  Integral printer (optional)
      −  Level indicator

Devices:

     −    Initial zero setting device (≤ 20% of Max)
     −   Semi-automatic zero setting device (≤ 4% of Max)
     −   Zero tracking (optional) (≤ 4% Max)
     −   Zero indicator


                                Page 3 of 5 pages

Page 4

OIML Certificate No.
                                                          R76/2006-A-GB1-18.02
                                                                      Revision 1
     −   Stable weight indicator
     −   Semi-automatic additive or subtractive tare weighing (T = ± ½ Max for single
             interval, or ± Max1 for dual interval)
     −   Tare indicating
     −   Preset tare
     −   Gravity compensation
     −   Printing (optional)
     −   Price-computing (weighed and non-weighed items)
     −   Price Look Up (PLU)
     −   Price-labelling configuration, in which case printing below Min is not allowed
     −  Memory storage (transactions)

Technical data (indicator):

Power supply                                  100 V – 230 Vac, 50/60 Hz
                                    5 V, 3.6 Ah battery (chargeable during operation)
Maximum number of scale intervals                         6 000
Operating temperature range                                          - 10 °C to + 40 °C
Maximum Tare value                             ± ½ Max for single interval
                                              ± Max1 for dual interval
Load cell excitation voltage                               5 VDC
Load cell impedance                                     350 
Minimum input voltage per verification scale                      1.5 V
interval
Measuring range minimum voltage                          0 mV
Measuring range maximum voltage                            19.5 mV
Fraction of maximum permissible error                                    pi = 0.5
Load cell cable (from indicator to load cell         0.45 m/mm2 (4-wire configuration)
junction box) - Maximum length

Load cell:

Any compatible load cell(s) may be used providing the following conditions are met:

      −   There is a respective OIML Certificate of Conformity (R60) issued for the load cell.
      −   The certificate contains the load cell types and the necessary load cell data required
              for the manufacturer’s declaration of compatibility of modules, and any particular
             installation requirements. A load cell marked NH is allowed only if humidity testing to
         R76 has been conducted on this load cell.
      −   The compatibility of the load cells and indicator is established by the manufacturer
          by means of the compatibility of modules calculation at the time of verification.
      −   The load cell transmission conforms to a standard type.

Alternatively, the instruments may be fitted with one of the following ZEMIC load cells, model
L6D:

    Max (kg)          6           6/15         15         15/30        30

      Min (g)          40         40         100        100        200
      e = (g)           2            2/5          5           5/10         10

    T = - (kg)          3          5.998          7.5        14.995        15

 Load cell Emax (kg)      12         25         25         40         40




                                Page 4 of 5 pages

Page 5

OIML Certificate No.
                                                          R76/2006-A-GB1-18.02
                                                                      Revision 1
Software:


The software is held in firmware on the circuit board, and has the identification number
V02.xx.xx, with xx.xx reflecting non-legally relevant changes. The software version number is
displayed at power-up.

Access to the legally relevant parameters and download of software is only possible via the
calibration switch on the main board.


Interfaces


The instrument may have the following interface types:

          −  USB
          −  Ethernet
          −  RS232

The instruments may be connected to an Electronic Point of Sale (EPOS), Electronic Cash
Register (ECR) or Electronic Fund Transfer (EFT/ECU).

Sealing:


Access to the electronics, load cell and calibration switch is prevented by sealing the enclosure
using a tamper-evident method – wire and seal solution.


Alternatives:


There are currently no authorised alternatives.





                                Page 5 of 5 pages