R76/2006-A-GB1-18.02 Rev. 1
Page 1
OIML Member State OIML Certificate No.
United Kingdom of Great Britain R76/2006-A-GB1-18.02
and Northern Ireland Revision 1
OIML CERTIFICATE ISSUED UNDER SCHEME A
OIML Issuing Authority NMO
Stanton Avenue
Teddington
TW11 0JZ
United Kingdom
Person responsible: Mannie Panesar – Head of Technical Services
Applicant Xiamen Balance Electronic Technology Co., Ltd.
Room 1001-1, No.15-16, Tongan Industrial Park
Meixi Road, Tongan District
Xiamen
PR China
Manufacturer The applicant
Identification of the B Series (BPS, BRS and BLS models)
certified type (the characteristics are defined in the Descriptive Annex)
This OIML Certificate attests the conformity of the above identified type (represented by the
sample(s) identified in the OIML type evaluation report) with the requirements of the following
Recommendation of the International Organization of Legal Metrology (OIML):
OIML R 76-1, Edition: 2006
For accuracy class: III
The OIML Issuing Authority
Issue date: 24 January 2019
G Stones
Technical Manager
For and on behalf of the Head of Technical Services
NMO I Stanton Avenue I Teddington I TW11 OJZ I United Kingdom
Tel +44 (0) 20 8943 7272 I Fax +44 (0) 20 8943 7270 I Web www.gov.uk/government/organisations/office-for-product-safety-and-standards
NMO is part of the Office for Product Safety and Standards within the Department for Business, Energy & Industrial Strategy
Page 2
OIML Certificate No.
R76/2006-A-GB1-18.02
Revision 1
This OIML Certificate relates only to metrological and technical characteristics of the type of
measuring instrument covered by the relevant OIML Recommendation identified above.
This OIML Certificate does not bestow any form of legal international approval.
The conformity was established by the results of tests and examinations provided in the
associated OIML type evaluation report:
No. P02123 dated 02 March 2018 that includes 16 pages
The technical documentation relating to the identified type is contained in documentation file:
No. P02123-D dated 02 March 2018
OIML Certificate History
Revision No. Date Description of the modification
Revision 0 02 March 2018 Certificate first issued.
Revision 1 24 January 2019 Correction to description of characteristics, and
addition of Technical data, for the instrument.
.
Important note:
Apart from the mention of the Certificate’s reference number and the name of the OIML
Member State in which the Certificate is issued, partial quotation of the Certificate and of the
associated OIML type evaluation report(s) is not permitted, although either may be
reproduced in full.
Page 2 of 5 pages
Page 3
OIML Certificate No.
R76/2006-A-GB1-18.02
Revision 1
DESCRIPTIVE ANNEX
Characteristics of the instrument:
The B Series comprises a BPS indicator (model) connected to a range of load cells to form a
family of Class III, mains or battery-operated, self-indicating, single or dual-interval, non-
automatic weighing instruments. The BPS indicator may be designated as the BPS and their
variants, BRS and BLS models depending upon the construction.
Max ≤ 30 kg
Min ≥ 40 g
e ≥ 2 g
n ≤ 6000 (for single-interval)
ni ≤ 3000 (for dual-interval)
The instrument may be used for direct sales to the public.
Model variants and designation:
Model Display Variant designation Options Remarks
BPS-A, BPS-A3
BPS-B, BPS-B3 RS232 Integral front and rear displays.
BPS-X, BPS-X3
LCD BPS-A1, BPS-A4
Integral front display and pole-
BPS or BPS-B1, BPS-B4 RS232
mounted rear display.
LED BPS-X1, BPS-X4
BPS-A2, BPS-A5
Pole-mounted front and rear
BPS-B2, BPS-B5 RS232
displays.
BPS-X2, BPS-X5
RS232 Pole-mounted front and rear
BRS LCD ---- USB displays.
Ethernet Integral printer.
RS232 Pole-mounted front and rear
BLS LCD ---- USB displays.
Ethernet Integral printer.
Construction:
− Plastic enclosure
− Plastic / Stainless Steel load receptor
− Dual, integral or pole-mounted, LCD/LED display
− Operator keypad
− Integral printer (optional)
− Level indicator
Devices:
− Initial zero setting device (≤ 20% of Max)
− Semi-automatic zero setting device (≤ 4% of Max)
− Zero tracking (optional) (≤ 4% Max)
− Zero indicator
Page 3 of 5 pages
Page 4
OIML Certificate No.
R76/2006-A-GB1-18.02
Revision 1
− Stable weight indicator
− Semi-automatic additive or subtractive tare weighing (T = ± ½ Max for single
interval, or ± Max1 for dual interval)
− Tare indicating
− Preset tare
− Gravity compensation
− Printing (optional)
− Price-computing (weighed and non-weighed items)
− Price Look Up (PLU)
− Price-labelling configuration, in which case printing below Min is not allowed
− Memory storage (transactions)
Technical data (indicator):
Power supply 100 V – 230 Vac, 50/60 Hz
5 V, 3.6 Ah battery (chargeable during operation)
Maximum number of scale intervals 6 000
Operating temperature range - 10 °C to + 40 °C
Maximum Tare value ± ½ Max for single interval
± Max1 for dual interval
Load cell excitation voltage 5 VDC
Load cell impedance 350
Minimum input voltage per verification scale 1.5 V
interval
Measuring range minimum voltage 0 mV
Measuring range maximum voltage 19.5 mV
Fraction of maximum permissible error pi = 0.5
Load cell cable (from indicator to load cell 0.45 m/mm2 (4-wire configuration)
junction box) - Maximum length
Load cell:
Any compatible load cell(s) may be used providing the following conditions are met:
− There is a respective OIML Certificate of Conformity (R60) issued for the load cell.
− The certificate contains the load cell types and the necessary load cell data required
for the manufacturer’s declaration of compatibility of modules, and any particular
installation requirements. A load cell marked NH is allowed only if humidity testing to
R76 has been conducted on this load cell.
− The compatibility of the load cells and indicator is established by the manufacturer
by means of the compatibility of modules calculation at the time of verification.
− The load cell transmission conforms to a standard type.
Alternatively, the instruments may be fitted with one of the following ZEMIC load cells, model
L6D:
Max (kg) 6 6/15 15 15/30 30
Min (g) 40 40 100 100 200
e = (g) 2 2/5 5 5/10 10
T = - (kg) 3 5.998 7.5 14.995 15
Load cell Emax (kg) 12 25 25 40 40
Page 4 of 5 pages
Page 5
OIML Certificate No.
R76/2006-A-GB1-18.02
Revision 1
Software:
The software is held in firmware on the circuit board, and has the identification number
V02.xx.xx, with xx.xx reflecting non-legally relevant changes. The software version number is
displayed at power-up.
Access to the legally relevant parameters and download of software is only possible via the
calibration switch on the main board.
Interfaces
The instrument may have the following interface types:
− USB
− Ethernet
− RS232
The instruments may be connected to an Electronic Point of Sale (EPOS), Electronic Cash
Register (ECR) or Electronic Fund Transfer (EFT/ECU).
Sealing:
Access to the electronics, load cell and calibration switch is prevented by sealing the enclosure
using a tamper-evident method – wire and seal solution.
Alternatives:
There are currently no authorised alternatives.
Page 5 of 5 pages