R61/2017-B-NL1-20.02
OIML Certificate
OIML Member State The Netherlands
Number R61/2017-B-NL1-20.02 Project number 2228215 Page 1 of 3
Issuing authority
NMi Certin B.V.
Person responsible: M. Boudewijns
Applicant and Manufacturer
Premier Tech
1, Avenue Premier
Rivière-du-Loup (Québec)
Canada G5R 6C1
Identification of the certified type
An Automatic gravimetric filling instrument
An Automatic gravimetric filling Instrument Type : PTF-XXXX (X=0...9)
Characteristics
See next page
This OIML Certificate is issued under scheme B.
This Certificate attests the conformity of the above identified Type (represented by the sample(s) identified in the OIML Test Report) with the requirements of the following Recommendation of the International Organization of Legal Metrology (OIML):
OIML R 61 - Edition 2017 (E) for accuracy class Ref (0,2)
This Certificate relates only to the metrological and technical characteristics of the type of measuring instrument covered by the relevant OIML International Recommendation above-identified. This Certificate does not bestow any form of legal international approval.
Important note: Apart from the mention of the Certificate's reference number and the name of the OIML Member State in which the Certificate was issued, partial quotation of the Certificate and of the associated OIML Test Report(s) is not permitted, although either may be reproduced in full.
Issuing Authority
NMi Certin B.V., OIML Issuing Authority NL1 31 March 2020
Certification Board
This document is issued under the provision that no liability is accepted and that the applicant shall indemnify third-party liability.
OIML Certificate
Number R61/2017-B-NL1-20.02 Project number 2228215 Page 2 of 3
The conformity was established by the results of tests and examinations provided in the associated OIML Reports:
For the indicator / analog data processing device model IT8000ET (Systec GmbH):
No. NMi-13200671-01 dated 24 July 2014 that includes 57 pages;
No. NMi-13200671-05 dated 24 July 2014 that includes 11 pages;
No. NMi-15200613-01 dated 21 December 2015 that includes 24 pages;
No. NMi-2267348-01 dated 22 October 2019 that includes 11 pages.
For the primary display / terminal / secondary display:
No. NMi-1900207-01 dated 2 June 2017 that includes 20 pages;
No. NMi-1900207-02 dated 31 May 2017 that includes 9 pages;
No. NMi-2249932-01 dated 21 December 2018 that includes 14 pages.
For the load cell model Z6 (Hottinger Baldwin Messtechnik GmbH):
No. R60/2000-NL1-06.07A dated 09 June 2006 that includes 38 pages;
No. R60/2000-NL1-06.07B dated 09 June 2006 that includes 16 pages;
No. NMi-13200686-01 dated 12 March 2014 that includes 26 pages.
For the load cell model PW22 (Hottinger Baldwin Messtechnik GmbH):
No. NMi-16200809-01 dated 31 January 2017 that includes 51 pages;
No. NMi-16200809-02 dated 31 January 2017 that includes 46 pages.
For the automatic gravimetric filling instrument:
No. NMi-2228215-01 dated 31 March 2020 that includes 30 pages.
Characteristics of the automatic gravimetric filling instrument
| Method of operation | filling by one weighing cycle | ||
| Reference accuracy class | Ref(0,2)the operational accuracy classX(x)是 determined at the time of putting into use | ||
| Electromagnetic environment class | E2 | ||
| Climatic environment | temperature range | -10℃/+40℃ | |
| humidity | Indicator | Mechanical assembly | |
| non-condensing | condensing | ||
| intended location | closed | open and closed | |
| Maximum capacity main station | Maxm depends on the load cells used | ||
| Maximum capacity top-up station | Maxto depending on the load cells used | ||
| Minimum capacity main station | Minm See tables below | ||
| Minimum capacity top-up station | Minto: See tables below | ||
| Rated minimum fill | Minfill≥Minm+Minto | ||
| Maximum fill | Maxfill≤Maxm+Maxto | ||
| Number of load receptors | 2 | ||
OIML Certificate
OIML Member State The Netherlands
Number R61/2017-B-NL1-20.02 Project number 2228215 Page 3 of 3
Minimum capacity (Min) for stations with automatic zero-setting or automatic tare-setting with a maximum time interval of 15 minutes:
| Average number of loads per fill: | 1 | |||
| Accuracy class: | X(0,2) | X(0,5) | X(1) | X(2) |
| d[g] | Min[g] | |||
| 0,5 | 178,0 | 35,5 | 18,0 | 9,0 |
| 1 | 1067 | 142 | 36 | 18 |
| 2 | 2134 | 426 | 142 | 36 |
| 5 | 5335 | 2135 | 1065 | 180 |
| 10 | 16000 | 4270 | 2130 | 1070 |
| 20 | 32000 | 8540 | 4260 | 2140 |
| 50 | 80000 | 32000 | 16000 | 5350 |
| ≥100 | 1600d | 640d | 320d | 160d |
Minimum capacity (Min) for stations with automatic zero-setting or automatic tare-setting as part of every weighing cycle:
| Average number of loads per fill: | 1 | |||
| Accuracy class: | X(0,2) | X(0,5) | X(1) | X(2) |
| d[g] | Min[g] | |||
| 0,5 | 28,0 | 11,0 | 5,5 | 3,0 |
| 1 | 111 | 22 | 11 | 6 |
| 2 | 334 | 44 | 22 | 12 |
| 5 | 1665 | 335 | 110 | 30 |
| 10 | 3330 | 1330 | 330 | 110 |
| 20 | 6660 | 2660 | 1340 | 340 |
| 50 | 25000 | 6650 | 3350 | 1650 |
| 100 | 50000 | 20000 | 6700 | 3300 |
| 200 | 100000 | 40000 | 20000 | 6600 |
| ≥500 | 500d | 200d | 100d | 50d |