Skip to content

← R51

R51/2006-A-DK2-24.02

Applicant
Shanghai Teraoka Electronic Co. Ltd.
Issuer
DK2
Issuing year
2024
Status
Valid

Source PDF (certificates/R51/2006/r51-2006-dk2-2024-02.pdf) · extracted by OCR from the digitalized tier of the corpus.

R51/2006-A-DK2-24.02

OIML Member State Denmark

OIML Certificate No.

R51/2006-A-DK2-2024.02

OIML CERTIFICATE ISSUED UNDER SCHEME A

OIML Issuing Authority
Name: FORCE Certification A/S Address: Park Allé 345, 2605 Brøndby, Denmark Person responsible: Per Rafn Crety
Applicant
Name: Shanghai Teraoka Electronic Co., Ltd. Address: No. 6058 of Nanting Road, Tinglin town, Jinshan District Shanghai CHINA
Manufacturer: Shanghai Teraoka Electronic Co., Ltd.
Identification of the certified type (the detailed characteristics will be defined in the additional pages) XCK-30/XCK-60
Designation of the module (if applicable) Automatic Catchweighing instrument
This OIML Certificate attests the conformity of the above identified type (represented by the sample(s) identified in the OIML type evaluation report) with the requirements of the following Recommendation of the International Organization of Legal Metrology(OIML): OIML R 51-1, Edition(year):2006 For accuracy class(if applicable):XIII or Y(a)
Revision No.DateDescription of the modification
Initial version09 August 2024-

Descriptive annex

Characteristics

  • Accuracy class: X(III), Y(a)

  • Weighing range: Single-interval

  • Weighing mode: Dynamic

  • Maximum capacity (Max): 30 and 60 kg

  • Minimum capacity (Min): $ \geq50\times e $

  • Verification scale interval (e=): $ \geq10\mathrm{g} $

  • Number of verification scale intervals (n): $ \leq 3 0 0 0 $

  • Belt speed: 30 m/min

  • Warm-up time: None

  • Temperature range: -10 $ ^{\circ} \mathrm{C} $ to $ +40 , \mathrm{^\circ C} $

  • Supply voltage: 230 VAC, 50/60 Hz

  • Electromagnetic class: E2

  • Humidity: Non-condensing

Software

Identification of the software version is performed during power-up.

The approved software version is v4.xx, where xx can be 00-99 and represents minor non-legal changes.

Devices

  • Initial zero setting device ( $ \leq20% $ of Max)

  • Automatic zero setting device ( $ \leq4% $ of Max)-dynamic mode only

  • Semiautomatic zero setting device ( $ \leq4% $ of Max)-static mode only

  • Zero tracking device ( $ \leq4% $ of Max)-static mode only

  • No motion detection and indication

  • Detection of significant fault

Interfaces

  • Ethernet for communication to peripherals.

  • USB (for setup of the instrument only)

The interface does not have to be secured.