R46/2012-A-NL1-23.04 Rev. 1

OIML Certificate

OIML Member State The Netherlands

Number R46/2012-A-NL1-23.04 revision 1

Project number 3906012

Page 1 of 4

Issuing authority

NMi Certin B.V. Person responsible: M.Ph.D. Schmidt

Applicant and Saudi Meters Company ltd.

Manufacturer 2nd Industrial Area

4719 Riyadh 14331-7141 Unit No.14

Kingdom of Saudi Arabia

Identification of the certified type

A measuring instrument Type: MA309MT3LSA or MA309MT4LSA

Characteristics

See page 2 and further.

This OIML Certificate is issued under scheme A.

This Certificate attests the conformity of the above identified type (represented by the sample(s) identified in the OIML Type Evaluation Report) with the requirements of the following Recommendation of the International Organization of Legal Metrology (OIML):

R 46-1/-2 (2012) "Active electrical energy meters"

Accuracy class

C for MA309MT4LSA

Accuracy class

D for MA309MT3LSA

This Certificate relates only to the metrological and technical characteristics of the type of measuring instrument covered by the relevant OIML International Recommendation identified above. This Certificate does not bestow any form of legal international approval.

Important note: Apart from the mention of the Certificate's reference number and the name of the OIML Member State in which the Certificate was issued, partial quotation of the Certificate and of the associated OIML Type Evaluation Report(s) is not permitted, although either may be reproduced in full.

Issuing Authority

NMi Certin B.V., OIML Issuing Authority NL1 17 June 2025

Certification Board

This document is issued under the provision that no liability is accepted and that the applicant shall indemnify third-party liability.

This document is digitally signed and sealed. The digital signature can be verified in the blue ribbon at the top of the electronic version of this certificate.

OIML Certificate

Number R46/2012-A-NL1-23.04 revision 1

Project number 3906012

Page 2 of 4

  • No. NMi-3630882-03 dated 8 September 2023 that includes 60 pages;

  • No. NMi-3630882-04 dated 8 September 2023 that includes 12 pages.

The conformity was established by the results of tests and examinations provided in the associated reports:

  • No. NMi-3906012-01 dated 17 June 2025 that includes 30 pages.

Characteristics of the measuring instrument

In Table 1 the general characteristics of the measuring instrument are presented.

Table 1 General characteristics

General characteristics MA309MT3LSA
Meter typeStatic
Connection mode(phase, wires, elements)3p,3w,3e(CT/VT connected)3p,4w,3e(CT/VT connected)
Direction of energy flow/registersTwo-registers,bi-directional
Terminal arrangement3P3W:DIN438573P4W:BS Type
Protective classClassII
Environmental application
Ambient temperature range-25℃to+70℃(tested up to+80℃)
Humidity class3P3W:H23P4W:H2
IP Rating/environmental use3P3W:IP54(indoor)3P4W:IP54(indoor)
Meter quantities
Nominal voltage($U_{nom}$)3P3W:3x110V3P4W:3x57,73/100...3x120/209
Nominal frequency($f_{nom}$)60Hz
Maximum current($I_{max}$)6A
Basic current($I_{n}$)1A or1.5A
Transitional current($I_{tr}$)0.1A
Minimum current($I_{min}$)0.01A or0.015A
Starting current($I_{st}$)0.001A or0.0015A
Meter constant10.000imp./kWh

OIML Certificate

OIML Member State The Netherlands

Number R46/2012-A-NL1-23.04 revision 1

Project number 3906012

Page 3 of 4

Product version
Hardware versionKF13A430 Main V1.1
Power supply board(PS)KF13A430 PS V1.1
Communication Module versionCL101KG:KF01L064V3.4
Communication Module versionCL101KG:KF01L064V3.4
Communication Module versionCL102KG:KF01L1534GV1.1
Software identificationLR:4303Checksum:7741D0E8
General characteristics MA309MT4LSA
Meter typeStatic
Connection mode(phase, wires,elements)3p,4w,3e(CT connected)
Direction of energy flow/registersTwo-registers,bi-directional
Terminal arrangementDIN43857
Protective classCategory2
Environmental application
Ambient temperature range-25℃to+70℃
Humidity classH2
IP Rating/environmental useIP54(indoor)
Meter quantities
Nominal voltage($U_{nom}$)3x133/230V...3x230/400V
Nominal frequency($f_{nom}$)60Hz
Maximum current($I_{max}$)6A
Basic current($I_{n}$)1.5A
Transitional current($I_{tr}$)0.1A
Minimum current($I_{min}$)0.015A
Starting current($I_{st}$)0.0015A
Meter constant10.000imp./kWh
Product version
Hardware versionKF13A427MainV1.1
Power supply board(PS)KF13A427PSV1.1
Module versionCL101KG:KF01L064V3.4
Software identificationLR:4202Checksum:E893748D

OIML Certificate

OIML Member State The Netherlands

Number R46/2012-A-NL1-23.04 revision 1 Project number 3906012

Page 4 of 4

Certificate history:

This revision replaces the previous version.

RevisionDateDescription of the modification
08 September 2023Initial issue
117 June 2025MA309MT3LSA meter is changed from a 3P3W configuration to a 3P4W configuration, changed in voltage from 3x110V to 3x57,73/100V...3x120/209V and update of communication module CL101KG communication which includes NB+2G+GPS and additional module CL102KG which includes 4G+2G+GPS and a change of operating temperature from-25℃...+70℃ to-25℃...+80℃