Applicant
Inhemeter Co., Ltd
Issuer
CN2
Issuing year
2026
Status
Valid

Source PDF (certificates/R46/2012/r46-2012-cn2-2026-08.pdf) · extracted by OCR from the digitalized tier of the corpus.

R46/2012-A-CN2-26.08

OIML CERTIFICATE

ISSUED UNDER SCHEME A

OIML Issuing Authority Name: National Institute of Metrology, China Address: No.18, Bei San Huan Dong Lu, Chaoyang Dist., Beijing, P. R. China Person responsible: Mr. Li Wentao

Applicant Name: Inhemeter Co., Ltd.

Address: 8/F&9/F, 1A, Software Park, Southern Hi-Tech Zone, Nanshan District,

518054 Shenzhen, P. R. China

Manufacturer Name: Inhemeter Co., Ltd.

Address: 8/F&9/F,1A,Software Park,Southern Hi-Tech Zone,Nanshan District,

518054 Shenzhen,P.R. China

Identification of the Single Phase Smart Energy Meter certified type i100,220 V,0.25-0.5(80) A,50 Hz (Further characteristics on page 2)

This OIML Certificate attests the conformity of the above identified type (represented by the sample(s) identified in the OIML type evaluation report) with the requirements of the following Recommendation of the International Organization of Legal Metrology (OIML):

OIML R46 - Edition 2012

For accuracy class: Class B

This OIML Certificate relates only to metrological and technical characteristics of the type of measuring instrument covered by the relevant OIML Recommendation identified above.

This OIML Certificate does not bestow any form of legal international approval.

Important note: Apart from the mention of the Certificate's reference number and the name of the OIML Member State in which the Certificate is issued, partial quotation of the Certificate and of the associated OIML type evaluation report(s) is not permitted, although either may be reproduced in full.

OIML Issuing Authority:

Date:

National Institute of Metrology, China

26 June 2026

OIML Issuing Authority

中国OIML证书发证机构

No.18, Bei San Huan Dong Lu, Chaoyang Dist, Beijing, 100029, P.R.China +861064525646 oimlia@nim.ac.cn www.nim.ac.cn

Li Wentao

Director

National Institute of Metrology, China

OIML Member StateOIML Certificate No.
P. R. ChinaR46/2012-A-CN2-26.08

The conformity was established by the results of tests and examinations provided in the associated OIML type evaluation report:

No. TER-R46/2012-CN2-26.08 dated 23 June 2026 that includes 24 pages

and the associated OIML test report:

No. ZQS-NJDLO-2026060001 dated 15 June 2026 that includes 79 pages

OIML Certificate History

Revision No.DateDescription of the modification
026 June 2026Initial issue

Characteristics of the Instrument

Meter type(electromechanical/static):Static
Accuracy class:Class B
Nominal voltage, $U_{\mathrm{nom}}$:220V
Nominal frequency,$f_{\mathrm{nom}}$:50Hz
Maximum current,$I_{\mathrm{max}}$:80A
Transitional current,$I_{\mathrm{tr}}$:0.5A
Minimum current,$I_{\mathrm{min}}$:0.25A
Starting current,$I_{\mathrm{st}}$:0.02A
Connection mode(phases,wires,elements):Direct-connected,One phase two wires,one element
Direction of energy flow/registers:Two-register,bi-directional
Register multiplier:1
Meter constant:1000imp/kWh
Specified clock frequencies:Energy measuring chip:6MHz,MCU:32.768kHz
Indoor/Outdoor:Outdoor
IP Rating:IP54
Terminal arrangement(e.g:BS,DIN):BS
Insulation protection class:II
Lower specified temperature:-25℃
Upper specified temperature:+55℃
Humidity class:H3
Tilt/Mounting position:Any position is allowed
Hardware version(s):INHE-i100-h5g-0c01-CA1-A1-20251023INHE-i100-h5g-0c01-C02-A1-20251023INHE-i100-h5g-0c01-CA3-A2-20251217INHE-i100-h5g-0b01-C04-A0.1-20250624
Software version(s):DKF3-0A-24062401;checksum:780A9D18.

Remarks:

Communication interfaces: Basic: 1 Optical port, 1 Bluetooth.

Extended: 1 4G Module, 1 G3-Hybrid Module, 1 G3 PLC Module, 1 HPLC+HRF Module.