Skip to content

← R46

R46/2012-A-NL1-21.14

Applicant
Holley Technology Ltd.
Issuer
NL1
Issuing year
2021
Status
Valid

Source PDF (certificates/R46/2012/r046-2012-nl1-2021-14.pdf) · extracted by OCR from the digitalized tier of the corpus.

R46/2012-A-NL1-21.14

OIML Certificate

OIML Member State The Netherlands

Number R46/2012-A-NL1-21.14 Project number 2538770 Page 1 of 2

Issuing authority Person responsible:

NMi Certin B.V. M. Boudewijns

Applicant and Manufacturer

Holley Technology Ltd.

No.181 Wuchang Avenue

Yuhang District

Hangzhou

P.R. China

Identification of the certified type

An active electrical energy meter Type: DTSD545-CT

Characteristics

See page 2 and further

This OIML Certificate is issued under scheme A

This Certificate attests the conformity of the above identified type (represented by the sample(s) identified in the OIML Type Evaluation Report) with the requirements of the following Recommendation of the International Organization of Legal Metrology (OIML):

R 46-1/-2 (2012) "Active electrical energy meters"

Accuracy class

This Certificate relates only to the metrological and technical characteristics of the type of measuring instrument covered by the relevant OIML International Recommendation identified above. This Certificate does not bestow any form of legal international approval.

Important note: Apart from the mention of the Certificate's reference number and the name of the OIML Member State in which the Certificate was issued, partial quotation of the Certificate and of the associated OIML Type Evaluation Report(s) is not permitted, although either may be reproduced in full.

Issuing Authority

NMi Certin B.V., OIML Issuing Authority NL1 30 March 2021

Certification Board

This document is issued under the provision that no liability is accepted and that the applicant shall indemnify third-party liability.

OIML Certificate

OIML Member State The Netherlands

Number R46/2012-A-NL1-21.14 Project number 2538770 Page 2 of 2

  • No. NMi-2509324-01a dated 30 March 2021 that includes 61 pages;

  • No. NMi-2538770-01 dated 30 March 2021 that includes 39 pages;

The conformity was established by the results of tests and examinations provided in the associated reports:

  • No. NMi-2538770-03 dated 30 March 2021 that includes 14 pages.

Characteristics of the measuring instrument

In Table 1 the general characteristics of the measuring instrument are presented.

Table 1 General characteristics

General characteristics
Meter typeStatic
Connection mode(phase, wires,elements)3p,4w,3e
Direction of energy flow/registersTwo-registers,bi-directional.
Terminal arrangementBS
Protective classCategory2
Environmental application
Ambient temperature range-40℃to+70℃(3k7) - tested up to+75℃ as a specific customer requirement
Humidity classH2
IP Rating/environmental useIP54/indoor
Meter quantities
Nominal voltage($U_{nom}$)3x133/230V and 3x230/400V
Nominal frequency($f_{nom}$)60Hz
Maximum current($I_{max}$)6A
Transitional current($I_{tr}$)0,075A
Minimum current($I_{min}$)0,015A
Starting current($I_{st}$)0,0015A
Meter constant10.000imp./kWh
Product version
Hardware version17-X100-01VS1.1
Software identificationVersion:HLYCTV1-20200902 Checksum:1DF3D480