Skip to content

← R139

R139/2018-A-NL1-23.02 Rev. 0

Applicant
CZAR Metric System Private Limited
Issuer
NL1
Issuing year
2023
Status
Valid

Source PDF (certificates/R139/2018/r139-2018-nl1-2023-02-rev0.pdf) · extracted by OCR from the digitalized tier of the corpus.

R139/2018-A-NL1-23.02 Rev. 0

OIML Certificate

OIML Member State The Netherlands

Number R139/2018-A-NL1-23.02 revision 0 Project number 2502536 Page 1 of 6

Issuing authority NMi Certin B.V. Person responsible: M.Ph.D. Schmidt

Applicant and Manufacturer CZAR Metric System Private Limited Plot No. A-451 MIDC Industrial Area, Mahape Navi Mumbai 400710 Maharashtra, India

Identification of the CNG Dispenser

certified type

Manufacturers mark: Czar

Type: CZC-******[1]

Characteristics See following pages

This OIML Certificate is issued under scheme A.

This Certificate attests the conformity of the above identified type (represented by the sample(s) identified in the OIML Type Evaluation Report) with the requirements of the following Recommendation of the International Organization of Legal Metrology (OIML):

R 139:2018 "Compressed gaseous fuel measuring systems for vehicles"

Accuracy class 1,5

This Certificate relates only to the metrological and technical characteristics of the type of measuring instrument covered by the relevant OIML International Recommendation identified above. This Certificate does not bestow any form of legal international approval.

This certificate and supporting reports comply with the requirements of OIML-CS-PD-07 clause 6.2.

Important note: Apart from the mention of the Certificate's reference number and the name of the OIML Member State in which the Certificate was issued, partial quotation of the Certificate and of the associated OIML Type Evaluation Report(s) is not permitted, although either may be reproduced in full.

[1] Where " $ \star $ " can be a number or a letter for representing different configurations of the dispenser.

Issuing Authority

OIML Certificate

Number R139/2018-A-NL1-23.02 revision 0 Project number 2502536 Page 2 of 6

The conformity was established by the results of tests and examinations provided in the associated report:

  • No. NMi-2502536-04 dated 4 May 2023 that includes 27 pages.

Characteristics of the CNG Dispenser

CNG Dispenser CZC-******* series

In Table 1 the general characteristics of the CNG dispenser are presented.

The construction of the CNG dispenser is recorded in the Documentation folder no. CF2502536-1.

Table 1 General characteristics of the CNG dispenser

Minimum-maximum flow rateWithin the flow ranges of the applicable measurement sensor see table 5 and/or 6
Minimum measured quantity1kg
Maximum filling pressure of the gasWithin the maximum pressure of the applicable measurement sensor see table 5 and/or 6
Maximum storage pressure500Bar
Accuracy class1.5
Environmental classesE1/M2
Ambient temperature range-25-+55℃; condensing humidity
Product temperature rangeWithin the product temperature ranges of the applicable measurement sensor see table 5 and/or 6
Intended for the measurement ofCompressed Natural Gas(CNG)
Power supply voltage185-245V AC;50Hz

Each CZC-******* dispenser consists at least of:

  • One measurement transducer (Coriolis mass meter CNGmass (E+H) or Coriolis mass meter CNG 050 (Emerson)).

  • One electronic calculating/indicating device (CZ series calculator).

  • Optionally, a printer may be connected to the dispenser as follows:

  • Printer mounted on the dispenser door, powered and communication through the dispenser;

  • Printer mounted on the side of the dispenser, powered and communication through the dispenser;

Remote printer connected via the POS communication cable.

The calculating/indicating device can have a maximum of 4 main displays, allowing it to configure and control 4 nozzles (meters), out of which 4 nozzles (meters) can be simultaneously operated.

OIML Certificate

OIML Member State The Netherlands

Number R139/2018-A-NL1-23.02 revision 0 Project number 2502536 Page 3 of 6

A maximum of one nozzle (meter) can be connected to each calculating/indicating device's main display.

Approved input - Mass meter communication cable via RS-485

Approved output - POS communication cable via RS-485

All communication cables (POS and Mass meter communication) should be shielded cables.

The characteristics of the mentioned parts of the dispenser are presented at table 2 and higher.

Essential parts of the CZC-***** series CNG dispensers

The conformity of the following parts was established by the results of tests and examinations provided in the associated reports:

Part:

Calculating/indicating device

Producer:

CZAR Metric System Private Limited

Type:

CZ Series

Documentation folder:

DF2502536-2

No. NMi-2502536-01 dated 27 October 2021 that includes 119 pages;

Reports:

No. NMi-2502536-03 dated 4 May 2023 that includes 34 pages.

Table 2 General characteristics of the calculating/indicating device type CZ series

Maximum volume indication6 digits(4 integers and 2 decimals)
Maximum unit price5 digits(3 integers and 2 decimals)
Maximum price to pay7 digits(5 integers and 2 decimals)
Environmental classesE1/M2/H3(condensing humidity)
Ambient temperature range-25℃/+55℃
Power supply230VAC50Hz
Maximum number of nozzles4
Maximum number of main indicating device4
Maximum number of nozzles connected to each indicating device1
Approved inputMass meter communication cable via RS-485(shielded)
Approved outputPOS communication cable via RS-485(shielded)
Mass Meter communicationRS-485 communication protocol

OIML Certificate

OIML Member State The Netherlands

Number R139/2018-A-NL1-23.02 revision 0 Project number 2502536 Page 4 of 6

Table 3 Software identification of the calculating/indicating device type CZ series

BoardFirmware versionHash code
CPU BoardCNG CZ-CPU_V2.2ad345a06221995f83b3faf6289c16a9996cea16ee7f5e05816943a17daf23473
Main Display cum CPU BoardCNG CZ-DIS_V2.223c41eea883465355ab629e56facc82cec186d7f6ae10ebbd8aada746cb52d99

Software version verification of the calculating/indicating device type CZ series The software versions and checksums can be displayed on the LCD display by following the below procedure:

On the alphanumeric keypad on the dispenser press SETUP $ \rightarrow $ P2 $ \rightarrow $ enter unique password by a user with sufficient rights $ \rightarrow $ ENTER this puts the dispenser in maintenance mode.

Then press 5 $ \rightarrow $ 1 $ \rightarrow $ 1 $ \rightarrow $ 1 for CPU board

or 5 $ \rightarrow $ 1 $ \rightarrow $ 1 $ \rightarrow $ 2 for Main Display board.

Table 4 Legally relevant parameter list of the calculating/indicating device type CZ series

Process codeProcess code nameValue / range
122Unit Rate5 digits (XXX.XX)
212Product Grade3 Characters (XXX)
243No flow No Fuel30 (sec)
51LogTransaction, Calibration Change, Unit Rate Change, Density Change, Error
311View Last CalView K Factor
214Date & Timedd:mm:yy,hh:mm:ss
511PCBA Soft DetailView board details
52Model InfoView model details
521Serial NumberView serial number of Dispenser

OIML Certificate

OIML Member State The Netherlands

Number R139/2018-A-NL1-23.02 revision 0 Project number 2502536 Page 5 of 6

Part:

Producer:

Type:

Measurement transducer

Endress+Hauser Flowtec AG.

Documentation folder:

Reports:

CNGmass

TC10997-1

No. CPC-607296-1a dated 7 February 2007;

No. CPC-10200012-02a dated 8 February 2010;

No. NMi-16200831-01 dated 13 July 2017;

No. NMi-16200831-02 dated 19 July 2017;

No. NMi-2665464-01 dated 5 April 2022.

Table 5 General characteristics of the measurement transducer type CNGmass

Minimum-maximum flow rate0,3-30kg/min(sizeDN08)0,8-80kg/min(sizeDN15)1,5-150kg/min(sizeDN25)
MMQ1kg
Maximum pressure350bar(g)
Intended for the measurement ofCompressed Natural Gas(CNG)
Environment classesM2/E2
Ambient temperature range-40℃/+55℃;condensing humidity
Fluid temperature range-50℃/+125℃
Power supply Voltage20...28VAC;50/60Hz;10...30VDC
Software identificationSW Version number:1.01.00Checksum:0x13BD2D46

OIML Certificate

OIML Member State The Netherlands

Number R139/2018-A-NL1-23.02 revision 0 Project number 2502536 Page 6 of 6

Part:

Producer:

Measurement transducer

Type:

Emerson Process Management Flow B.V.

CNG 050

Documentation folder:

TC11012-1

Reports:

No. CPC/9200574-2 dated 26 January 2010.

No. NMi-1900487-01 dated 14 July 2017.

Table 6 General characteristics of the measurement transducer type CNG050

Minimum-maximum flow rate1,3-77kg/min
MMQ1kg
Maximum pressure317 or 345 bar(g)(depending on flange type)
Intended for the measurement ofCompressed Natural Gas(CNG)
Environment classesM2/E2
Ambient temperature range-40℃/+55℃;condensing humidity
Fluid temperature range-25℃/+55℃
Power supply voltage24VDC±20%(withMVDDirectConnectI.S)15-26VDC
Software identificationSW Version number:3.52Checksum:3C4A

Production location

The CNG dispenser is produced at one of the following production locations:

  • CZAR Metric System Private Limited, Plot No. A-451, Central Road, MIDC Industrial Area,

  • Mahape Pin code 400710, Maharashtra India.

  • CZAR Metric System Private Limited, Plot No.C-541, MIDC Industrial Area, Pawne,

Navi Mumbai 400705, Maharashtra, India.

Certificate history:

This revision replaces the previous version.

RevisionDateDescription of the modification
04 May 2023Initial issue