Skip to content

← R139

R139/2018-A-NL1-22.07 Rev. 0

Applicant
Cetil Dispensing Technology, S.L.
Issuer
NL1
Issuing year
2022
Status
Valid

Source PDF (certificates/R139/2018/r139-2018-nl1-2022-07-rev0.pdf) · extracted by OCR from the digitalized tier of the corpus.

R139/2018-A-NL1-22.07 Rev. 0

OIML Certificate

OIML Member State The Netherlands

Number R 139/2018-A-NL1-22-07 revision 0

Project number 2546086

Page 1 of 11

Issuing authority NMi Certin B.V. Person responsible: M.Ph.D. Schmidt

Applicant and Manufacturer Cetil Dispensing Technology, S.L. C/Pelaya 37 Polígono Industrial Río de Janeiro 28110 Algete (Madrid) Spain

Identification of the certified type

A compressed gas (CG) dispenser for hydrogen

A compressed gas (CG) dispenser for hydrogen Manufacturers mark: Cetil Type: E30 H2 A x x* y y y y**

Characteristics See following page(s)

Remarks * x x details the dispenser configuration, see characteristics for details

** y y y y details the dispensing mode, see characteristics for details

This OIML Certificate is issued under scheme A.

This Certificate attests the conformity of the above identified type (represented by the sample(s) identified in the OIML Type Evaluation Report) with the requirements of the following Recommendation of the International Organization of Legal Metrology (OIML):

R 139:2018 "Compressed gaseous fuel measuring systems for vehicles"

Accuracy class 2 or 4

This Certificate relates only to the metrological and technical characteristics of the type of measuring instrument covered by the relevant OIML International Recommendation identified above. This Certificate does not bestow any form of legal international approval.

This certificate and supporting reports comply with the requirements of OIML-CS-PD-07 clause 6.2.

Important note: Apart from the mention of the Certificate's reference number and the name of the OIML Member State in which the Certificate was issued, partial quotation of the Certificate and of the associated OIML Type Evaluation Report(s) is not permitted, although either may be reproduced in full.

Issuing Authority

NMi Certin B.V., OIML Issuing Authority NL1 10 October 2022

Certification Board

This document is issued under the provision that no liability is accepted and that the applicant shall indemnify third-party liability.

This document is digitally signed and sealed. The digital signature can be verified in the blue ribbon at the top of the electronic version of this certificate.

OIML Certificate

OIML Member State The Netherlands

Number R 139/2018-A-NL1-22-07 revision 0 Project number 2546086 Page 2 of 11

The conformity was established by the results of tests and examinations provided in the associated report(s):

  • No. NMi-2546086-01 dated 5 August 2022 that includes 28 pages.

Characteristics of the measuring instrument

In Table 2 the general characteristics of the measuring instrument are presented.

  • A flow meter (measurement sensor and transducer); and

  • A calculating/indicating device.

In Table 3 the overview of the essential parts of the measuring instrument are presented.

The construction of the measuring instrument is recorded in the Documentation folder no. T9010-1.

The type designation of the dispenser details the actual configuration. E30 H2 A is the "frame model" with the extension "xx" and "yyyy" which details the configuration as per table 1. Each column of the table gives the possible values per item of the type designation.

Table 1 Configurations

Dispenser information(xx)Dispenser Measuring system(s) information(yyyy)
Frame modelNumber of measurement systemsNumber of physical inputs1Dispensing mode4Number of physical inputs1Other options1(Heat exchanger)
E30 H2A1(Single)1Hxx(Single hose,xx0 Bar)1X
2(Double)22HxxHF(Single hose,xx0 Bar,高流)2
3HxxYHxx(Dual hose,Hxx&Hxx)33
HxxHFYHxx* (Dual hose,HxxHF&Hxx)31(E)
2(E)
  1. Non-essential indication

  2. Double systems have two measurement systems in one dispenser

  3. Dual hose systems use one measurement system for two hoses: hoses cannot be used simultaneously

  4. xx indicates the operating pressure (i.e. 35 for 350 bar or 70 for 700 bar)

OIML Certificate

OIML Member State The Netherlands

Number R 139/2018-A-NL1-22-07 revision 0

Project number 2546086

Page 3 of 11

The CG dispenser automatically depressurizes the entire section from the filling valve up to and including the hose via the purge valve for safety reasons. Delivery is only allowed when the purge valve is fully closed.

The CG dispenser performs a correction to account for the depressurization quantity, for this purpose the temperature, pressure and volume of the depressurization section needs to be known:

An example of type designation is E30 H2 A 23 H35HF 2X H70YH35 3X, for a dispenser with two measurement systems and three inputs. Where system 1 is a single H35HF with two inputs and system 2 is a H70YH35 with three inputs. Both systems have a heat exchanger.

  • The pressure and temperature are measured in the depressurization section.

  • The electronic calculating and indicating device monitors the pressure and temperature measurement for status and deviation from a secondary measurement. In case of abnormalities an alarm is raised, and the refuelling terminated.

  • The actual volume of the depressurization section is determined based on the components of the dispenser (Pipework/valves/hoses/etc) and configured in the calculating/indicating device.

Table 2 General characteristics

Flow rateDepending on flow sensor used
Minimum measured quantity1kg
Maximum pressureDepending on flow sensor used
Environmental classesM1 or M2(depending on flow sensor used)/E2
Ambient temperature range-40 to +55℃;condensing humidity
Product temperature rangeDepending on flow sensor used
Intended for the measurement ofHydrogen(H2)
Power supply voltage230AC;50Hz

OIML Certificate

OIML Member State The Netherlands

Number R 139/2018-A-NL1-22-07 revision 0

Project number 2546086

Page 4 of 11

Table 3 Overview parts of the measuring instrument

PartProducerTypeOIML certificateOIML ReportsRemarks
Measurement sensorEmerson Process Management Flow B.V.HPC015R139/2018-A-NL1-21.03-To be used with Emerson transducer.
Measurement transducerEmerson Process Management Flow B.V.700,800,820,1700,2500,2700,3500,3700 and 5700-See Table 4To be used with Emerson sensor.
Measurement sensorRheonikRHM04 or RHM10R139-2018-A-NL1-22-01-To be used with Rheonik transducer.
Measurement transducerRheonikRHE42 or RHE45R139-2018-A-NL1-22.04-To be used with Rheonik sensor.
Calculating indicating deviceCetilEAS2-See Table 5-

OIML Certificate

OIML Member State The Netherlands

Number R 139/2018-A-NL1-22-07 revision 0 Project number 2546086

Page 5 of 11

Table 4 General characteristics of the measurement transducer type 700,800,820,1700, 2500,2700,3500,3700 and 5700

ProducerEmerson Process Management Flow B.V.
Type700,800,820,1700,2500,2700,3500,3700 and 5700
Documentation folderTC8519-4(5700),TC7057-17(all other types)
ReportsNo.CPC-307228-1 dated21February2005 that include35 pages;No.CPC-607580-1 dated26April2007 that include32 pages;No.CPC-610406-2 dated29January2008 that include142 pages;No.CPC-710466-1 dated19November2008 that include64 pages;No.NMi-11200214-01 dated17May2011 that include13 pages;No.NMi-11200214-02 dated17May2011 that include16 pages;No.NMi-11200345-2 dated20October2011 that include10 pages;No.NMi-11200708-2 dated13February2012 that include15 pages;No.NMi-SO12200192-1 dated23May2012 that include15 pages;No.NMi-SO12200736-1 dated10January2013 that include16 pages;No.NMi-SO13200862-1 dated4June2013 that include15 pages;No.NMi-SO13203381-01 dated12September2013 that include15 pages;No.NMi-SO13204037-01 dated4November2013 that include16 pages;No.NMi-SO14200881-01 dated7March2014 that include15 pages;No.NMi-1901208-01 dated5July2018 that include114 pages;No.NMi-1901208-02 dated5July2018 that include17 pages;No.NMi-1902436-01 dated31July2018 that include27 pages;No.NMi-1902436-01 dated31July2018 that include27 pages;No.NMi-2571596-01 dated30September2021 that include38 pages;No.NMi-2571596-01 dated30September2021 that include32 pages;No.NMi-14200115-01 dated4December2015 that include68 pages;No.NMi-14200115-02 dated4December2015 that include52 pages;No.NMi-14200115-03 dated4December2015 that include10 pages;No.NMi-14200115-04 dated15January2016 that include15 pages;No.NMi-14200115-05 dated15January2016 that include15 pages;No.NMi-14200115-06 dated22April2016 that include21 pages;No.NMi-15200770-01 dated4February2016 that include9 pages.
Environmental classesM3/E3 for700,800,820,1700,2700,3500,3700,5700and dual pulse converterM2/E2 for2500
Ambient temperature range-40℃/+55℃700,800,820,1700,2700,3500,3700,dual pulse converter-25℃/+55℃for5700-40℃/+55℃for5700in case the measurement results can be read and/or recorded with an approved instrument
Power supply voltage18-30VDC for the82024VDC for the250085...265VAC or18...100VDC for the1700/2700/3500/3700100...240VAC or21...90VDC for the5700
Software revisionSee details on the following pages

OIML Certificate

OIML Member State The Netherlands

Number R 139/2018-A-NL1-22-07 revision 0

Project number 2546086

Page 6 of 11

The validated software versions and checksums are:

700 Core Processor
VersionChecksumVersionChecksumVersionChecksum
2.051FF2.7F666*)3.218D0
2.12B3F2.81DEA*)3.3B0D1
2.290053.0D00D*)3.4073A9
2.3D75B3.0-ETO1715397D6*)3.42F00C
2.4474F3.11-ETO19413**)14AD3.5011AA
2.514AD3.121F1B*)3.523C4A
2.6D732*)3.13-ETO189518BF8*)

*) Indicated as 14AD, corrected from v3.2

**) Linearization feature

800 Enhanced Core Processor
VersionChecksumVersionChecksumVersionChecksum
3.11891378AB3.91-ETO2115665F98DD74.60DDB76E3C
3.219893B9993.9447EB3E104.70AEB92E3F
3.30A73D25DA3.96756C1BFD4.80F1583A44
3.427FA82CE84.00C582F8434.96083BF9B
3.50D9343F054.028D61C3685.084D368E71
3.52132CCB634.1440860C635.182C541D9
3.6A9CA4E814.202983A9BE5.2BD69FDD6
3.61-ETO171709AA358FF4.21-ETO21931*)D63492595.22F4A8D922
3.7BE73CD624.40B280233F5.23-ETO45214B1D70450
3.71-ETO18982580D32B64.42D7BA08415.3065828884
3.88CA8E7D14.506B48C6245.33BF3164F6
3.81-ETO207757931CE3D4.51-ETO32353BC1660E8
3.958CB3E0C4.51-ETO33244D7B81135

Notes:

  • For the 800ECP v3.80 or higher: by writing ETO number 13511 in Modbus register 5005, the linearization feature is enabled.

  • 800 ECP versions lower than 5.xx are not compatible with hardware version v4 of the Enhanced Core Processor. There are three hardware versions of the 800:

  • 800 v1; identified with part number 20006069.

  • 800 v2; identified with part number 20016889.

This is the same as the v1 but equipped with RoHS components (Restriction of Hazardous Substances).

Number R 139/2018-A-NL1-22-07 revision 0

Project number 2546086

Page 7 of 11

  • 800 v3; identified with part number MMI-20020807, rev AD.

  • 800 v4; identifies with part number MMI-20020807, rev. AE.

This version uses the SSM2604 CODEC from a different supplier, resulting in:

  • Updated board electronics

  • Updated software version (version 5.00 and higher), which is backwards compatible with the previous hardware versions (v1, v2 and v3).

  • 800 v5; identifies with part number MMI-20088230, rev. AA.

  • This version uses the same CODEC as the v4 hardware, but with added compensation circuit and the removal of unused parts of the boards to simplify the lay-out.

  • 800 v6; identifies with part number MMI-20093828, rev. AA.

  • This version uses the ADAU1361 CODEC instead of the SSM2604 CODEC. The ADAU1361 is a more modern version with better future availability. This version needs software version 5.00 and higher.

See the documentation folder TC7057-17, section 800 Core Processor

*) Density Based Correction coefficients removed. To be used in gas application measuring Hydrogen or Helium.

820 Remote Dual Core Processor
VersionChecksumVersionChecksumVersionChecksum
1.0052FB1CF01.30AC56C4601.50F42A4B2C
1.10787951AA1.408B64EF94
1.203B7249F61.41073C45F2

Notes:

  • Fuel Consumption feature from v1.10 onwards is not approved.

  • 820 versions lower than 1.50 are not compatible with hardware version v2 of the Remote Dual Core Processor. There are two hardware versions of the 820:

  • 820 v1; identified with part number MMI-200229698 Rev. AB

  • 820 v2; identified with part number MMI-20029698 Rev. AC.

This version uses the SSM2604 CODEC from a different supplier, resulting in:

  • Updated board electronics

  • Updated software version (version 1.50 and higher), which is backwards compatible with the previous hardware version (v1).

See the documentation folder, section 820 Dual Core-Processor

1700/2700/2500
Software versions with no checksum
PartVersionRemark
17003.2,3.3,3.4,3.4.1,3.5.3,3.6,3.7,4.1,4.2
27004.0,4.1,4.2
25004.0,4.1,4.2

OIML Certificate

OIML Member State The Netherlands

Number R 139/2018-A-NL1-22-07 revision 0

Project number 2546086

Page 8 of 11

1700/2700/2500
VersionChecksumVersionChecksumVersionChecksum
5.0/1.07A7F0B396.4/1.3B77B25C97.1/1.388FB1B5C
5.1/1.095F0BC476.5/1.388FB1B5C7.2/1.39ECE81F1
5.12/1.0A14FBFB96.6/1.39ECE81F17.3/1.34A5365D4
5.2/1.0746CBE796.7/1.34A5365D48.0/1.31E1467F9
6.0/1.1BB615B556.8/1.31E1467F98.02/1.3201465F9
6.1/1.213176BE66.82/1.3201465F9
6.11-ETO192669B13F21A7.0/1.3B77B25C9
3500/3700
VersionChecksumVersionChecksumVersionChecksum
7.0/1.1A1C34F1C8.1/1.34279A0018.41-ETO2609731D36D05
7.1/1.1D5783FCF8.14/1.362F125F28.43-ETO31478E35DF3C0
7.2/1.120609FD38.2/1.4368139C58.50/1.51C146AF7
8.0/1.2158A12BD8.21-ETO23686D507F4648.51-ETO22243B18A0CB3
8.02-ETO189471CC007C48.3/1.48F65A9E9
8.03-ETO192992D6104C28.4/1.4227B10D2

See documentation folder page 7057/35-01 with an overview of the ETO Software for the different transmitters.

OIML Member State The Netherlands

OIML Certificate

Number R 139/2018-A-NL1-22-07 revision 0

Project number 2546086

Page 9 of 11

5700
VersionChecksumVersionChecksumVersionChecksum
Transmitter Software(Weights&Measures)[1]
1.20(1.0)2DF0D8E92.10(2.0)23DD33854.0(3.0)0E4997D5
1.30(1.1)ADE631BB3.0(3.0)061084004.07(4.0)44477758
1.85(2.0)ETO281300EA71B413.1(3.0)2DE64BB24.1(4.0)AFE0673B
2.00(2.0)2F52132D3.2(3.0)8CB1FE4B4.2(4.0)627B3E99
Internal Core Software
4.028D61C3684.60DDB76E3C5.20BD69FDD6
4.1440860C634.70AEB92E3F5.22F4A8D922
4.202983A9BE4.80F1583A445.3065828884
4.40B280233F4.906083BF9B5.33BF3164F6
4.42D7BA08415.084D368E71
4.506B48C6245.1082C541D9
PIC Firmware
8.00000DE9C
LCD PIC Firmware *)
3.0000081D5(1.20)3.000007442(1.30 and later)

Notes:

  • Internal core software versions lower than 5.xx are not compatible with the new Core Processor Board, reference EB-20084741, documentation numbers 8515/14-01 and 8519/14-02.

  • Internal core software versions higher than 5.xx are backwards compatible with the old Core Processor Board, reference EB-20025291, documentation numbers 8515/0-01 and 8519/0-02.

*) Between brackets the transmitter software is mentioned which belongs to the stated checksum.

OIML Certificate

OIML Member State The Netherlands

Number R 139/2018-A-NL1-22-07 revision 0

Project number 2546086

Page 10 of 11

Table 5 General characteristics of the calculating/indicating device type EAS2

ProducerCetil
TypeEAS2
Documentation folderTC8491-3
Reports-No.NMi-15200617-01 dated 14 April 2016 that includes 85 pages.-No.NMi-15200617-02 dated 14 April 2016 that includes 20 pages.-No.NMi-15200617-04 dated 14 April 2016 that includes 34 pages.
Maximum volume indication8 positions 99999999
Maximum unit price8 positions 99999999
Maximum price to pay8 positions 99999999
Environmental classesM3/E2/H3
Ambient temperature range-40℃/+55℃
Software identificationSee below table
Power supply voltage230 AC;50Hz

The validated software versions and checksums are:

ModuleSoftware versionDateChecksum
MCON02-0030-06-2264465ED1
MVIS9119A678
MEES458C8115
M4207305BF75

The legally relevant parameters are:

Parameter numberParameter descriptionSettingRemark
00.h.--Hoses Configuration Parameters (In the following parameters h refers to the number of hose and its value can be either 01 or 06)
00.h.07Hose number h hidden quantity.0-9999kg*10-2Must be set below 0,04kg(Emin)
00.01.08Fueling point 1 hose piping volume (Depressurization section)0-9999cm3Must be set according to actual dispenser depressurization volume
00.06.08Fueling point 2 hose piping volume (Depressurization section)0-9999cm3
00.20.09Fueling point 1 satellite hose piping volume (Depressurization section)0-9999cm3
00.20.10Fueling point 2 satellite hose piping volume (Depressurization section)0-9999cm3

OIML Member State The Netherlands

OIML Certificate

Number R 139/2018-A-NL1-22-07 revision 0

Project number 2546086

Page 11 of 11

Parameter numberParameter descriptionSettingRemark
11.00.--Display Parameters
11.00.06Display mass configuration10-87Left number represent the number of digits.The right number represents the number of decimals which must be set to 2 or higher,avoiding non-significant indications.
20.m.--Meter Configuration Parameters(In the following parameters m refers to the number of meter and its value can be either 01 or 02)
20.m.01Meter m type1=HPC0152=HPC0203=RHM044=RHM10Must be set according to the meter model used.
20.m.06Meter m systematic errorSystematic measurement error in1kg*10000kg.-999/+999Set during initial verification based if required based on performance testing
40.---.--Other General Parameters
40.00.05Unit price multiplication factor for amount calculation:0-x1.1-x10.2-x100.3-x1000.4-/10.5-/100.6-/1000.Must be set to 0 for EURO with three decimals
40.00.06Amount rounding typeThe amount is rounded to multiples of the value introduced.1-9999Must be set to 1 For EURO
40.01.03Timeout maximum time without pulses0-25510*sMust be set to 12 or less (less than 120 Seconds)
40.10.06Access code to calibration level setup menu.0-999999To be set during initial verification

Certificate history:

RevisionDateDescription of the modification
010 October 2022Initial revision