Skip to content

← R139

R139/2018-A-NL1-21.04 Rev. 1

Applicant
Dover Fueling Solutions UK Limited (Filial)
Issuer
NL1
Issuing year
2021
Status
Valid

Source PDF (certificates/R139/2018/r139-2018-nl1-2021-04-rev1.pdf) · extracted by OCR from the digitalized tier of the corpus.

R139/2018-A-NL1-21.04 Rev. 1

OIML Certificate

OIML Member State The Netherlands

Number R139/2018-A-NL1-21.04 revision 1 Project number 2573771 Page 1 of 6

Issuing authority Person responsible:

NMi Certin B.V. M.Ph.D. Schmidt

Applicant and Manufacturer

Dover Fueling Solutions UK limited (Filial)

Hanögatan 8

21124 Malmö

Sweden

Identification of the certified type

A CG dispenser (compressed gas) Type: Helix CNG

Characteristics

See page 2 and further

This OIML Certificate is issued under scheme A.

This Certificate attests the conformity of the above identified type (represented by the sample(s) identified in the OIML Type Evaluation Report) with the requirements of the following Recommendation of the International Organization of Legal Metrology (OIML):

R 139-1 (2018) "Compressed gaseous fuel measuring systems for vehicles"

Accuracy class 1,5

This Certificate relates only to the metrological and technical characteristics of the type of measuring instrument covered by the relevant OIML International Recommendation identified above. This Certificate does not bestow any form of legal international approval.

This certificate and supporting reports comply with the requirements of OIML-CS-PD-07 clause 6.2.

Important note: Apart from the mention of the Certificate's reference number and the name of the OIML Member State in which the Certificate was issued, partial quotation of the Certificate and of the associated OIML Type Evaluation Report(s) is not permitted, although either may be reproduced in full.

Issuing Authority

NMi Certin B.V., OIML Issuing Authority NL1 29 October 2021

NMi Certin B.V.

Thijsseweg 11

2629 JA Delft

The Netherlands

T +31 88 636 2332

certin@nmi.nl

www.nmi.nl

Certification Board

This document is issued under the provision that no liability is accepted and that the applicant shall indemnify third-party liability.

The notification of NMi Certin B.V. as Issuing Authority can be verified at www.oiml.org

This document is digitally signed and sealed. The digital signature can be verified in the blue ribbon at the top of the electronic version of this certificate.

OIML Certificate

OIML Member State The Netherlands

Number R139/2018-A-NL1-21.04 revision 1 Project number 2573771 Page 2 of 6

The conformity was established by the results of tests and examinations provided in the associated report(s):

  • No. NMi-1901591-01 dated 18 June 2018 that includes 19 pages;

  • No. NMi-2283414-01 dated 19 February 2021 that includes 34 pages.

Characteristics of the measuring instrument

In Table 1 the general characteristics of the measuring instrument are presented.

The construction of the measuring instrument is recorded in the Documentation folder no. T8935-1.

Table 1 General characteristics

Minimum-maximum flow rateWithin the flow ranges of the applicable measurement transducer, see table 2 or 3.
Minimum measured quantityCNGmass1kg
CNG0501kg
Maximum pressureCNGmass350 bar(g)
CNG050317 or 345 bar(g)(depending on flange type)
Accuracy class1.5
Environmental classesM1/E2
Ambient temperature range-25-+55℃;non condensing humidity
Product temperature rangeCNGmass-40-+55℃
CNG050-25-+55℃
Intended for the measurement ofCompressed Natural Gas

OIML Certificate

Number R139/2018-A-NL1-21.04 revision 1

Project number 2573771

Page 3 of 6

Each measuring instrument consists at least of:

  • One measurement transducer (meter);

The characteristics of the mentioned parts of the dispenser are presented at table 2 and higher.

The same housing of the dispenser can comprise of one or more measuring systems. When more than one measuring systems are in one housing, one calculating/indicating device may be a common part of the measuring systems.

  • One calculating/indicating device (calculator).

When two transfer points apply for the same measurement transducer, only one can be applied at the same time.

When applying two measurement transducers and each measurement transducer is destined to deliver separately, this configuration has to be considered as two dispensers.

OIML Certificate

OIML Member State The Netherlands

Number R139/2018-A-NL1-21.04 revision 1 Project number 2573771 Page 4 of 6

Parts of the measuring instrument

The conformity of the following parts was established by the results of tests and examinations provided in the associated report(s):

Part:

Producer:

Measurement transducer

Type:

Micro Motion

CNG050

Documentation folder:

Reports:

TC11012-1

No. C-BI-02-WV-0428 dated 28 May 2002 that includes 20 pages;

No. CPC-92005574-2 dated 26 January 2010 that includes 12 pages;

No. NMi-1900487-01 dated 17 July 2017 that includes 24 pages.

Table 2 General characteristics of the measurement transducer type CNG050

Flow rate range[kg/min]1,3-77kg/min
MMQ1kg
Maximum pressure317 or 345 bar(g)(depending on flange type)
Environmental classesM2/E2
Ambient temperature range-40-+55℃;non condensing humidity
Product temperature range-25-+55℃
Intended for the measurement ofCompressed Natural Gas
Power supply24VDC±20%(with MVD Direct Connect I.S)15-26VDC
Software identificationVersion number:3.52Checksum:3C4A

Installation conditions measurement transducer type CNG050 Installation of the meter with the MVD Direct Connect barrier is preferred to protect against EMI.

OIML Certificate

OIML Member State The Netherlands

Number R139/2018-A-NL1-21.04 revision 1 Project number 2573771 Page 5 of 6

Part:

Producer:

Type:

Documentation folder:

Reports:

Measurement transducer

Endress+Hauser Flowtec AG

CNGmass

TC10997-1

No. CPC-10200012-01 dated 8 February 2010 that includes 23 pages;

No. NMi-16200831-01 dated 7 July 2017 that includes 41 pages;

No. NMi-16200831-02 dated 19 July 2017 that includes 17 pages.

Table 3 General characteristics of the measurement transducer type CNGmass

Flow rate range[kg/min]See table 3 below
MMQSee table 3 below
Maximum pressure350 bar(g)
Environmental classesM2/E2
Ambient temperature range-40-+55℃;non condensing humidity
Product temperature range-50-+125℃
Intended for the measurement ofCompressed Natural Gas
Power supply26V AC;50/60Hz24V DC
Software identificationVersion number:01.01.00Checksum:0X13BD2D46

Table 4 General characteristics of the family of instruments type CNGmass

Meter sizeDN08DN15DN25
Minimum flow rate[kg/min]0.30.81.5
Maximum flow rate[kg/min]3080150
MMQ[kg]111
Maximum pressure[bar(g)]250250250
Diameter in/outlet[mm]81525

OIML Certificate

OIML Member State The Netherlands

Number R139/2018-A-NL1-21.04 revision 1 Project number 2573771 Page 6 of 6

Part:

Producer:

Type:

Documentation folder:

Reports:

Calculating/indicating device

Dover Fueling Solutions

OPT-ELT

TC8942-1

No. CPC-805983 dated 24 June 2008 that includes 48 pages;

No. NMi-15200585-01 dated 17 March 2016 that includes 29 pages;

No. NMi-1901591-01 18 June 2018 that includes 19 pages;

No. NMi-2283414-01 19 February 2021 that includes 34 pages.

Table 5 General characteristics of the calculating/indicating device type OPT-ELT

Maximum weight indicationxxx.xx digits
Maximum unit pricexxxx digits
Maximum price to payxxxxxx digits
Environmental classesM1/E2
Ambient temperature range-40℃/+55℃(for OTP-ELT with display part no.WM063074-0001)-25℃/+55℃(for OTP-ELT with display part no.WT009754-0001(TSO33108)和WT009754-0002(TSO33121))
Software identificationTOS01802.xxx or TOS002zzz.xx
Power supply230V AC(+10%-25%)50-60Hz

Production location

  • Dover Fueling Solutions UK limited (Filial), Hanögatan 8, 21124 Malmö, Sweden

  • Dover Fueling Solutions UK, Unit 3, Baker Road, Dundee, DD5 3RT, Scotland, UK

  • Tokheim India Private Limited, Building No 2, Plot 66 TTC Industrial Area, MIDC, Mahape, Navi Mumbai 400 710, Maharashtra, India

It is the decision and responsibility of the manufacturer Dover Fueling Solutions in which location the CNG dispensers are produced.

Certificate history:

This revision replaces the previous version.

RevisionDateDescription of the modification
Initial30 September 2021-
129 October 2021Editorial changes.