Skip to content

← R137

R137/2012-A-NL1-20.10 Rev. 10

Applicant
MeteRsit
Issuer
NL1
Issuing year
2025
Status
Valid

Source PDF (certificates/R137/2012/r137-2012-nl1-2020-10-rev10.pdf) · extracted by OCR from the digitalized tier of the corpus.

R137/2012-A-NL1-20.10 Rev. 10

OIML Certificate

OIML Member State The Netherlands

Number R137/2012-A-NL1-20.10 revision 10 Project number 3874399 Page 1 of 7

Issuing authority

NMi Certin B.V.

Person responsible: M.Ph.D. Schmidt

Applicant and Manufacturer

MeteRSit Viale dell'Industria,34 35129 Padova Italy

Identification of the certified type

A thermal-mass flow gas meter Type: x485xxx

Characteristics

See following page(s)

This OIML Certificate is issued under scheme A.

This Certificate attests the conformity of the above identified type (represented by the sample(s) identified in the OIML Type Evaluation Report) with the requirements of the following Recommendation of the International Organization of Legal Metrology (OIML):

R 137-1:2012 "Gas meters"

Accuracy class

This Certificate relates only to the metrological and technical characteristics of the type of measuring instrument covered by the relevant OIML International Recommendation identified above. This Certificate does not bestow any form of legal international approval.

This certificate and supporting reports comply with the requirements of OIML-CS-PD-07 clause 6.2.

Important note: Apart from the mention of the Certificate's reference number and the name of the OIML Member State in which the Certificate was issued, partial quotation of the Certificate and of the associated OIML Type Evaluation Report(s) is not permitted, although either may be reproduced in full.

Issuing Authority

NMi Certin B.V., OIML Issuing Authority NL1 4 February 2025

Certification Board

This document is issued under the provision that no liability is accepted and that the applicant shall indemnify third-party liability.

OIML Certificate

Number R137/2012-A-NL1-20.10 revision 10 Project number 3874399 Page 2 of 7

The conformity was established by the results of tests and examinations provided in the associated report(s):

  • No. NMi-15200299-02 dated 15 March 2016 that includes 45 pages;

  • No. NMi-16200387-02 dated 17 October 2016 that includes 61 pages.

  • No. NMi-SO16204082-01 dated 10 November 2016 that includes 15 pages;

  • No. NMi-16200852-01 dated 8 May 2017 that includes 13 pages;

  • No. NMi-1901756-02 dated 23 March 2018 that includes 12 pages;

  • No. NMi-1900623-02 dated 29 May 2017 that includes 17 pages;

  • No. NMi-1901029-02 dated 11 October 2017 that includes 14 pages;

  • No. NMi-1901403-02 dated 1 February 2018 that includes 21 pages;

  • No. NMi-1902208-02 dated 25 July 2018 that includes 14 pages;

  • No. NMi-2268368-02 dated 6 December 2018 that includes 10 pages;

  • No. NMi-2327085-02 dated 13 June 2019 that includes 3 pages;

  • No. NMi-1902287-02 dated 17 February 2020 that includes 18 pages;

  • No. NMi-2188742-02 dated 3 June 2020 that includes 16 pages;

  • No. NMi-2364857-02 dated 23 November 2020 that includes 26 pages;

  • No. NMi-2477858-02 dated 2 April 2021 that includes 19 pages;

  • No. NMi-2548615-01 dated 1 July 2021 that includes 17 pages;

  • No. NMi-2587901-02 dated 7 October 2021 that includes 16 pages;

  • No. NMi-2893273-02 dated 10 February 2022 includes 16 pages;

  • No. NMi-3093042-02 dated 10 February 2022 that includes 13 pages;

  • No. NMi-3476264-01 dated 3 May 2022 that includes 12 pages;

  • No. NMi-3543194-02 dated 28 July 2023 that includes 15 pages;

  • No. NMi-3766785-01 dated 3 September 2024 that includes 31 pages;

  • No. NMi-3777055-01 dated 3 October 2024 that includes 29 pages;

  • No. NMi-3874399-01 dated 4 February 2025 that includes 19 pages.

Characteristics of the measuring instrument

In Table 1 the general characteristics of the measuring instrument are presented. In Table 2 the software versions and associated checksums are presented. In Table 3 and 4 the characteristics of the family of instruments are presented. The construction of the measuring instrument is recorded in the Documentation folder no. T10362-56.

OIML Certificate

OIML Member State The Netherlands

Number R137/2012-A-NL1-20.10 revision 10

Project number 3874399

Page 3 of 7

Table 1 General characteristics

Destined for the measurement ofGas volume of natural gas, type H or L or Gas volume of natural gas, type H, L and E, with a Gross Wobbe Index between 39,1 MJ/m3 and 54,7 MJ/m3 at 15℃ and 1,01325 bar, including mixtures with a hydrogen concentration of up to 23% by volume.
Environmental classesM1/E2
Accuracy class1.5
Maximum pressure500 mbar
Ambient temperature range-25-+55℃
Gas temperature range-25-+55℃
Designed forCondensing humidity
OrientationHorizontal
Power supply voltageBattery powered

Table 2 Software identification

Software identificationVersion numberChecksumMeter size
EL10ADB2G1.6
EL40A7345A73G2.5
EL403F8C0F42G4 extended
EL10ADB2G4MMU6
E13203EF
E167D029
G182A1A8
G19218FB
G19303B6
G1941CCF
GL015812
GL108096
GL101FA8
I1928F41
GL201B98163C
GL20E06D5DC3
GL208EE0A289
GL408AAEF5ED
GL409658D989

OIML Member State The Netherlands

OIML Certificate

Number R137/2012-A-NL1-20.10 revision 10

Project number 3874399

Page 4 of 7

GL45 GL458C4516C6 423BE916
GL26923DD39BG4 MMU6 dot display
A132 A167 J182 J192 J193 J194 JL01 JL10 L192 JL40 JL40CA53 7199 BDC1 3484 4586 5FFA B0DE 7EEA D8DD A7BCEB12 568CB31FG6
B166 B183 B192 B194 BL01 BL10 BL40 BL80 BL806CA4 82D8 B8EF 22FA BD57 4175 AE0F5A61 A29F2615 228C7D05G10 MMU16
C182 C192 C194 CL01 CL10 CL11 F154 F166 CL13 CL40C9BE BC94 F780 62F5 B51F F7E8 E336 7D4C D1DD9B83 306988F6G16 MMU25
D182 D192 D194 DL01 DL10 DL11 H154 H166 DL13 DL40E589 E889 416D CBFE 38FA 3EF9 6B95 F29E 050A7042 52840ABDG25 MMU40
ML38D38DC219G40

OIML Member State The Netherlands

OIML Certificate

Number R137/2012-A-NL1-20.10 revision 10 Project number 3874399

Page 5 of 7

MMU-HydrogenDH2535A7CF47MMU40
GH256B004CFAMMU6
Metrology processing softwareEL303CA2E7AFG1.6G2.5G4 extended
EL31FCCC0334
EL3298ED4B7A
EL37DAE8303A
GL30457E70ACG4
GL317B3F312A
GL322044FB12
GL35A1919F0B
BootloaderJL30917875FBG6
JL319F7F23C6
JL321D9A869B
BootloaderO430375B8BF8GPRS
O431C6ECD32BNB-IoT
U530CD16D523WMBUS
W530CD16D523Walk-By

Table 3 General characteristics of the family of instruments

Meter sizeG1.6G2.5G4MMU6G4 ext.G6
Minimum flow rate $Q_{\mathrm{min}}$(m3/h)0,0160,0250,040,0160,06
Transitional flow rate $Q_{\mathrm{t}}$(m3/h)0,250,40,60,251
Maximum flow rate $Q_{\mathrm{max}}$(m3/h)2,546610
Overload flow rate $Q_{\mathrm{r}}$(m3/h)34,87,27,212
Indicating range(m3)99999 or 999999
Verification scale interval(m3)0,001
Nominal diameter[mm]19 or3232

OIML Certificate

OIML Member State The Netherlands

Number R137/2012-A-NL1-20.10 revision 10 Project number 3874399

Page 6 of 7

Table 4 General characteristics of the family of instruments

Meter sizeG10MMU16G16MMU25G25MMU40G40
Minimum flow rate $ Q_{\min} $ (m3/h)0,10,160,250,4
Transitional flow rate $ Q_{t} $ (m3/h)1,62,546,5
Maximum flow rate $ Q_{\max} $ (m3/h)16254065
Overload flow rate $ Q_{r} $ (m3/h)19,2304878
Indicating range (m3)999999
Verification scale interval (m3)0,001
Nominal diameter [mm]1 1/4" BS746or 5065Flange type02 PN16 DN65

Certificate history:

This revision replaces the previous versions.

RevisionDateDescription of the modification
Initial-
127 November 2020Addition of report No. NMi-2364857-02 and software update
27 October 2021Addition of meter types using SGM63xx measurement sensor Software updates
311 February 2022Addition of reports No. NMi-2893273-02 and NMi-3093042-02 for revised PCBs.
43 May 2022Addition of G1.6 version with SGM6101 Software update
56 October 202228 July 2023Addition of new housing for MMU6/Software versions addedAddition of pulse output battery cover for G10,G16,G25,MMU25 and MMU40 models.
622 November 2022New combined communication versionSoftware update
721 August 2023Correction of typo in revision number

OIML Member State The Netherlands

OIML Certificate

Number R137/2012-A-NL1-20.10 revision 10

Project number 3874399

Page 7 of 7

RevisionDateDescription of the modification
811 September 2024Dot display MMU6, new pcb and software version
93 October 2024Addition of G40 with parallel SGM6325 sensors. These sensors are fitting in a new housing with new sealing and use a new software version.
104 February 2025Addition of a G10/MMU16 version which contains 2 parallel SGM6306 sensors instead of a singular SGM6104 sensor. These sensors are fitted in a standard MMU6 housing with 1 1/4” BS746 connections and a new connector to the index.