R137/2012-NL1-2017.02

OIML Certificate of Conformity

OIML Member State The Netherlands

Number R137/2012-NL1-17.02 Project number SO16200998 Page 1 of 4

Issuing authority Person responsible:NMi Certin B.V. C. Oosterman
Applicant and manufacturerELGAS, s.r.o. Semtínská 211 Pardubice Czech Republic
Identification of the certified typeA rotary piston gas meter Type: EMR and EMR-Dual
CharacteristicsSee page 2 and further

This Certificate attests the conformity of the above identified type (represented by the sample(s) identified in the OIML Type Evaluation Report) with the requirements of the following Recommendation of the International Organization of Legal Metrology (OIML):

R 137-1 (2012) "Gas meters"

Accuracy class See table 2 and 3.

This Certificate relates only to the metrological and technical characteristics of the type of measuring instrument covered by the relevant OIML International Recommendation identified above. This Certificate does not bestow any form of legal international approval.

Important note: Apart from the mention of the Certificate's reference number and the name of the OIML Member State in which the Certificate was issued, partial quotation of the Certificate and of the associated OIML Type Evaluation Report(s) is not permitted, although either may be reproduced in full.

Issuing Authority

NMi Certin B.V., OIML Issuing Authority NL1 23 June 2017

C. Oosterman Head Certification Board

NMi Certin B.V.

Hugo de Grootplein 1

3314 EG Dordrecht

the Netherlands

T +31 78 6332332

certin@nmi.nl

www.nmi.nl

This document is issued under the provision that no liability is accepted and that the applicant shall indemnify third-party liability.

The notification of NMi Certin B.V. as Issuing Authority can be verified at www.oiml.org

OIML Certificate of Conformity

OIML Member State The Netherlands

Number R137/2012-NL1-17.02 Project number SO16200998 Page 2 of 4

The conformity was established by the results of tests and examinations provided in the associated report(s):

  • No. NMi-14200712-02 dated 30 January 2015 that includes 36 pages.

Characteristics of the measuring instrument

Table 1 gives the general characteristics of both meter types. Table 2, 3 and 4 on the following pages specify in detail the characteristics and essential parts of the EMR and EMR-Dual rotary piston gas meters. The construction of the measuring instrument is recorded in the Documentation folder no. T10774-1.

Table 1 General characteristics EMR and EMR-Dual

Destined for the measurement ofGas volume
Mechanical classM1
Electromagnetic classNot applicable(the meter has no electronics)
Ambient temperature range-25℃/+55℃
Gas temperature range-25℃/+55℃
OrientationHorizontal/Vertical up/Vertical down(all orientations)
Flow directionUni-directional(indicated with arrow)

OIML Certificate of Conformity

OIML Member State The Netherlands

Number R137/2012-NL1-17.02

Project number SO16200998

Page 3 of 4

Table 2 Essential characteristics EMR

Volume*V[dm3]G-valueQmax[m3/h]MinimumQmin[m3/h]Qt[m3/h]Maximumpmax[bar]DiameterD[mm]Accuracyclass
0,25G6100,250,5101Threaded1,0
G10160,250,8101Threaded1,0
G16250,251,25101Threaded1,0
G25400,252101Threaded1,0 or 1,5
0,39G10160,250,810140 or 501,0
G16250,251,2510140 or 501,0
G25400,25210140 or 501,0 or 1,5
G40650,253,210140 or 501,0 or 1,5
0,61G16250,251,2510140 or 501,0
G25400,25210140 or 501,0 or 1,5
G40650,253,210140 or 501,0 or 1,5
G651000,25510140 or 501,0 or 1,5
0,73G16250,21,2510140 or 501,0
G25400,2210140 or 501,0 or 1,5
G40650,23,210140 or 501,0 or 1,5
G651000,2510140 or 501,0 or 1,5
1,16G1001600,481250 or 801,0 or 1,5
G40650,43,210150 or 801,0 or 1,5
G651000,4510150 or 801,0 or 1,5
G1001600,4810150 or 801,0 or 1,5
1,45G1602500,6512,51250 or 801,0 or 1,5
G651000,6510180 or 1001,0 or 1,5
G1001600,6810180 or 1001,0 or 1,5
1,81G1602500,612,510180 or 1001,0 or 1,5
G651000,6510180 or 1001,0 or 1,5
G1001600,6810180 or 1001,0 or 1,5
G1602500,612,510180 or 1001,0 or 1,5
1,98G2504001201280 or 1001,0 or 1,5
G1001601810180 or 1001,0 or 1,5
G160250112,510180 or 1001,0 or 1,5
3,17G2504001,612,510180 or 1001,0 or 1,5
G4006502,5321280 or 1001,0 or 1,5
G2504002,520101100 or 1501,0 or 1,5
5,15G4006502,532101100 or 1501,0 or 1,5
G65010006,255012100 or 1501,0 or 1,5
  • See remark on next page.

OIML Certificate of Conformity

OIML Member State The Netherlands

Number R137/2012-NL1-17.02 Project number SO16200998 Page 4 of 4

Table 3 Essential characteristics EMR-Dual

Volume*V[dm3]G-valueQmax[m3/h]minimumQmin[m3/h]Qt[m3/h]maximumpmax[bar]**DiameterD[mm]Accuracyclass
2,41160250112,521/10180 or 1001,0 or 1,5
2504002,52021/10180 or 1001,0 or 1,5
3,962504002,52021/101100 or 1501,0 or 1,5
40065043221/101100 or 1501,0 or 1,5
650100043221/101150 or 2001,0 or 1,5
6,3440065043221/101150 or 2001,0 or 1,5
65010006,55021/101150 or 2001,0 or 1,5
  • On the name plate of the rotary meter the cyclic volume can be given in two possible formats:
  1. with two digits behind the comma as stated in table 2 and 3, or

  2. with a number containing 6 significant digits. In this case a HF pulse value can be accurately derived from the spinning rotors with an optical sensor.

** The EMR-Dual can be delivered as a low pressure $ \left( P_{\mathrm{m a x}}=2 1 \mathrm{b a r} \right) $ or a high pressure $ \left( P_{\mathrm{m a x}}=1 0 1 \mathrm{b a r} \right) $ variant.

Table 4 Register built up

meter sizeMinimum number of drumscontrol-element[m3]
before the commabehind the comma
G6530.0002
G10- G65620.002
G100- G650710.02

Installation conditions

For this rotary meter specific installation conditions are not applicable.