R137/2012-NL1-2014.03 Rev. 0

OIML Certificate of Conformity

OIML Member State The Netherlands

Number R137/2012-NL1-14.03 revision 0 Project number 14200712 Page 1 of 5

Issuing authority NMi Certin B.V. Person responsible: C. Oosterman

Applicant Flow Meter Group B.V. Meniststraat 5c 7091 ZZ Dinxperlo The Netherlands

Manufacturer Flow Meter Group B.V. Meniststraat 5c 7091 ZZ Dinxperlo The Netherlands

Identification of the turbine gas meter certified type Type: FMT-L, FMT-S and FMT-Lx

This certificate attests the conformity of the above identified type (represented by the sample(s) identified in the OIML Type Evaluation Reports) with the requirements of the following Recommendation of the International Organization of Legal Metrology (OIML):

R 137-1 (2012) "Gas meters"

This certificate relates only to the metrological and technical characteristics of the type of measuring instrument covered by the relevant OIML International Recommendation identified above. This certificate does not bestow any form of legal international approval.

Important note: Apart from the mention of the certificate's reference number and the name of the OIML Member State in which the certificate was issued, partial quotation of the certificate and of the associated OIML Type Evaluation Report(s) is not permitted, although either may be reproduced in full.

Issuing Authority

NMi Certin B.V., OIML Issuing Authority NL1 24 December 2014

C. Oosterman Head Certification Board

This document is issued under the provision that no liability is accepted and that the applicant shall indemnify third-party liability.

The notification of NMi Certin B.V. as Issuing Authority can be verified at www.oiml.org

Parties concerned can lodge objection against this decision, within six weeks after the date of submission, to the general manager of NMi (see www.nmi.nl).

OIML Certificate of Conformity

OIML Member State The Netherlands

Number R137/2012-NL1-14.03 revision 0 Project number 14200712 Page 2 of 5

The conformity was established by the results of tests and examinations provided in the associated OIML Type Evaluation Reports:

  • No. NMi-14200702-01 dated 18 December 2014 that includes 13 pages;

  • No. NMi-14200104-01 dated 15 September 2014 that includes 14 pages;

  • No. NMi-14200712-02 dated 23 December 2014 that includes 35 pages.

Characteristics of the gas meter:

Table 1 gives the general characteristics of all three turbine meter types. Table 2 and 3 on the following pages specify in detail the characteristics and essential parts of the turbine meters.

Destined for the measurement ofGas volume
Mechanical classM2
Electromagnetic classNot applicable(the meter has no electronics)
Ambient temperature range-40℃/+70℃
Gas temperature range-40℃/+70℃
OrientationHorizontal/Vertical up/Vertical down(all orientations)
Flow directionUni-directional(indicated with arrow)
OIML Member State The Netherlands

OIML Certificate of Conformity

Number R137/2012-NL1-14.03 revision 0

Project number 14200712

Page 3 of 5

Main characteristics1.2Essential characteristics1.4Conditional parts1.1Essential parts
TypeDN bodyDN cartr.G-valueQmaxQtQminNumber of drumsBefore and after commaControl elementBlade angleBlade qtyBearing dimensionsInside diameterxOutside diameterxWidth in mm
MR 1:200..101bar(g)MR 1:304..101bar(g)MR 1:508..101bar(g)standard bearings0..101bar(g)Optional bearings4...101bar(g)
frontrearfrontrear
-mmmm-m3/hm3/hm3/hm3/hm3/h-m3/hdegree-frontrearfrontrear
FMT-Lx5080100160328537/10,0255123x6x32x5x23x8x43x6x3
1602505012,5854514
250400802012,583516
FMT-L,FMT-S,orFMT-Lx8080100160328537/10,0255123x6x32x5x23x8x43x6x3
1602505012,5854514
250400802012,583516
40065013032,52012,53516
FMT-Lx10080100160328537/10,0255123x6x32x5x23x8x43x6x3
1602505012,5854514
250400802012,583516
FMT-L,FMT-S,orFMT-Lx1001001602505012,5857/10,0255123x8x43x6x35x10x33x6x3
250400802012,584514
40065013032,52012,53516
100016003208050328/00,23516
FMT-Lx1501001602505012,5857/10,0255123x8x43x6x35x11x55x16x55x11x5
250400802012,584514
40065013032,52012,53516
FMT-L,FMT-S,orFMT-Lx15015040065013032,52012,57/10,0255125x11x55x11x55x16x55x11x5
65010002005032204514
100016003208050328/00,23516
FMT-Lx15020065010002005032207/10,0255125x16x55x16x58x22x75x16x5
100016003208050324514
1600250050012580503516
FMT-Lx20015040065013032,52012,57/10,0255125x11x55x11x55x16x55x11x5
65010002005032204514
100016003208050324514
FMT-L,FMT-S,orFMT-Lx20020065010002005032207/10,0255125x16x55x16x58x22x75x16x5
100016003208050324514
1600250050012580503516
OIML Member State The Netherlands

OIML Certificate of Conformity

Number R137/2012-NL1-14.03 revision 0

Project number 14200712

Page 4 of 5

Table3
Main characteristics1.2Essential characteristics1.4Conditional parts1.1Essential parts
TypeDN bodyDN cartr.G-valueQmaxQtQminNumber of drumsBefore and after commaControl elementBlade angleBlade qtyBearing dimensionsInside diameterx Outside diameterx Width in mm
0..101bar(g)MR 1:304..101bar(g)MR 1:500..101bar(g)
standard bearingsOptional bearings
-mmmm-m3/hm3/hm3/hm3/h-m3/hdegree-frontrearfrontrear
FMT-Lx2002501000160032050328/00,2452410x26x86x16x512x28x86x19x6
16002500500805045/3024
25004000800125803024
25004000800125803024
FMT-S, or FMT-Lx2502501000160032050328/00,2452410x26x86x16x512x28x86x19x6
16002500500805045/3024
25004000800125803024
4000650013002161303024
FMT-Lx2503001000160032050328/00,2452410x26x86x16x512x28x86x19x6
16002500500805045/3024
25004000800125803024
4000650013002161303024
FMT-S FMT-Lx3003001600250050080508/00,2452412x28x86x19x617x40x128x22x7
250040008001258045/3024
4000650013002161303024
4000650013002161303024
FMT-Lx3004002500400080133808/00,2452415x35x118x22x717x40x128x22x7
40006500130021613045/3024
4000650013002161303024
4000650013002161303024
FMT-S, or FMT-Lx4004002500400080133808/00,2452415x35x118x22x717x40x128x22x7
40006500130021613045/3024
4000650013002161303024
4000650013002161303024
FMT-Lx4005004000650013002161308/00,2452420x47x1410x26x820x47x2010x26x8
40006500130021613045/3024
4000650013002161303024
4000650013002161303024
FMT-Lx5004002500400080133808/00,2452415x35x118x22x717x40x128x22x7
40006500130021613045/3024
4000650013002161303024
4000650013002161303024
FMT-S, or FMT-Lx5005004000650013002161308/00,2452420x47x1410x26x820x47x2010x26x8
40006500130021613045/3024
4000650013002161303024
4000650013002161303024

OIML Certificate of Conformity

OIML Member State The Netherlands

Number R137/2012-NL1-14.03 revision 0 Project number 14200712 Page 5 of 5

Installation conditions:

The FMT-L meter can be equipped with two different flow straighteners. When the large one is installed a straight inlet pipe of 1xDN is applicable. With the small one installed a straight inlet pipe of 5xDN shall be applied.

The FMT-S can only be equipped with the large flow straightener, and therefore needs a minimum of 1xDN straight pipe length in front of the inlet.

The FMT-Lx meter has no installation requirements concerning straight inlet tubing. The inlet flow straightener is identical to the FMT-S configuration due to the fact that the FMT-Lx and FMT-S have identical cartridges.

The necessary straight pipe length is stated on the name plate of the meter.

Any components which could affect the gas flow must be avoided within the prescribed inlet pipe length. The inlet pipe must be designed as a straight pipe section of the same nominal diameter as the gas meter.