Skip to content

← R137

R137/2012-A-CZ1-23.01

Applicant
Zhejiang Songchuan Instruments Technology Co., Ltd
Issuer
CZ1
Issuing year
2023
Status
Valid

Source PDF (certificates/R137/2012/r137-2012-cz1-2023-01.pdf) · extracted by OCR from the digitalized tier of the corpus.

R137/2012-A-CZ1-23.01

OIML Certification SystemCMI
OIML Member State Czech RepublicOIML Certificate No. R137/2012-A-CZ1-2023.01
OIML CERTIFICATE ISSUED UNDER SCHEME A
OIML Issuing Authority Name: Czech Metrology Institute Address: Okružní 31, 638 00 Brno Czech Republic Person responsible: Jan Kalandra
Applicant Name: Zhejiang Songchuan Instrument Technology Co., Ltd. Address: No.1 Luhai Road, Eastern New District, 317511 Wenling, Taizhou City Zhejiang, China
Manufacturer Name: Zhejiang Songchuan Instrument Technology Co., Ltd. Address: No.1 Luhai Road, Eastern New District, 317511 Wenling, Taizhou City Zhejiang, China
Identification of the certified type (the detailed characteristics will be defined in the additional pages) diaphragm gas meter type: JBD1.6-SA, JBD2.5-SA (or G1.6, G2.5)
Designation of the module (if applicable) ---
This OIML Certificate attests the conformity of the above identified type (represented by the sample(s) identified in the OIML type evaluation report) with the requirements of the following Recommendation of the International Organization of Legal Metrology (OIML): OIML R137 Edition (year): 2012, Including Amendment 2014 For accuracy class (if applicable): 1.5
Revision No.DateDescription of the modification
-9 June 2023Issuing Certificate
Identification, signature and stamp The OIML Issuing Authority RNDr. Pavel Klenovský Head of Certification Body Date: 9 June 2023
Important note: Apart from the mention of the Certificate's reference number and the name of the OIML Member State in which the Certificate is issued, partial quotation of the Certificate and of the associated OIML type evaluation report(s) is not permitted, although either may be reproduced in full

1 General information concerning the type

Information indicated on the instrument
Manufacturer's trade markJBD1.6-SA, JBD2.5-SA(or G1.6,G2.5)
Type designationJBD1.6-SA,JBD2.5-SA(or G1.6,G2.5)
Accuracy class1.5
Cyclic volume(if applicable)0.9dm3
Minimum pressurepmin0 bar(g)
Maximum pressurepmax0.5 bar(g)
Ambient temperature range(-25...+55)℃
Gas temperature range(-25...+55)℃
Base pressure(if applicable)Not applicable
Base temperature(if applicable)Not applicable
tsp(if applicable)Not applicable
Electrical powerNot applicable
Identification of softwareNot applicable

Example of the labels:

Photos of the constructions:

2 Additional information concerning the type

Size G$Q_{\mathrm{max}}(\mathrm{m}^{3}/\mathrm{h})$$Q_{t}(\mathrm{m}^{3}/\mathrm{h})$$Q_{\mathrm{min}}(\mathrm{m}^{3}/\mathrm{h})$Cyclic volume $V(\mathrm{dm}^{3})$Maximum permissible pressure loss $\Delta P$ in $Q_{\mathrm{max}}(\mathrm{Pa})$$P_{\mathrm{max}}(\mathrm{kPa})$
G2.54.00.40.0250.920050
G1.62.50.250.0160.920050

The gas meter can be produced with the distance between connections (male threads): 130 mm, 110 mm, 90 mm

The male threads used in gas meters JBD1.6-SA, JBD2.5-SA (or G1.6, G2.5): M30x2, G7/8", G3/4"

Dimensions of diaphragm gas meters JBD1.6-SA, JBD2.5-SA (or G1.6, G2.5) (part 1/2)

Cesky metrologicky institut

Dimensions of diaphragm gas meters JBD1.6-SA, JBD2.5-SA (or G1.6, G2.5) (part 2/2)

Location of 8 seals on diaphragm gas meters JBD1.6-SA, JBD2.5-SA (or G1.6, G2.5):