R134/2006-DK3-2011.02
OIML CERTIFICATE OF CONFORMITY
Issuing authority Name: Address:
DELTA
Venlighedsvej 4
2970 Hørsholm
Denmark
Person responsible:
J. Hovgaard Jensen
Applicant Name: Address:
Esit Elektronik Ltd. Sti.
Nişantepe Mahallesi Fabrikalar Sokak No:8
Çekmeköy
İstanbul
TURKEY
Manufacturer of the certified pattern:
Esit Elektronik Ltd. Sti.
Identification of the certified pattern:
Automatic instrument for weighing road vehicles in motion Type: AR-WIM Further characteristics are set out on page 2.
This certificate attests the conformity of the above mentioned pattern (represented by the samples identified in the associated test report) with the requirements of the following Recommendation of the International Organization of Legal Metrology (OIML):
R134 edition 2006
This certificate relates only to the metrological and technical characteristics of the pattern of the instrument concerned, as covered by the relevant OIML International Recommendation.
This certificate does not bestow any form of legal international approval.
Page 1. This certificate includes 2 pages
OIML Certificate N° R134/2006-DK3-11.02
The conformity was established by tests described in the associated test reports from DELTA, DK, no. DANAK-196561, that includes 72 pages DELTA, DK, no. DANAK-1910543, that includes 68 pages DELTA, DK, no. DANAK-1911226, that includes 44 pages
The issuing authority: DELTA, OIML Issuing Authority DK3 22 February 2011
J. Hovgaard Jensen Certification Officer
Characteristics
| Accuracy class for vehicle mass | 0.5 | 1 | 2 | |
| Accuracy class for single axle load | B or C | B or C or D | C or D | |
| Maximum capacity | Max | 30000kg | ||
| Minimum capacity | Min | ≥50×d | ≥10×d | |
| Scale interval | d | 10kg | 10kg≤d≤20kg | 10kg≤d≤50kg |
| Maximum operation speed | Vmax | 8km/h | ||
| Minimum operation speed | Vmin | 1km/h | ||
| Maximum transit speed: | 30km/h | |||
| Maximum number of axles: | ≤15 | |||
| Direction of travel | dual | |||
| Scale interval for stationary load | E | ≥1.25μV | ||
| Power supply voltage: | 12-24VDC | |||
| Connected load cells | Shall comply withR60 | |||
| Temperature range for the indicator | -10℃/+40℃ | |||
Important note:
Apart from the mention of the certificate's reference number and the name of the OIML Member State in which the certificate was issued, partial quotation of the certificate or of the associated test report is not permitted, though they may be reproduced in full.