Skip to content

← R134

R134/2006-A-DK2-24.01 Rev. 1

Applicant
Tunaylar Baskül Sanayi ve Ticaret A.S.
Issuer
DK2
Issuing year
2025
Status
Valid

Source PDF (certificates/R134/2006/r134-2006-dk2-2024-01-rev1.pdf) · extracted by OCR from the digitalized tier of the corpus.

R134/2006-A-DK2-24.01 Rev. 1

OIML Certificate No. R134/2006-A-DK2-24.01 Revision 1

OIML CERTIFICATE ISSUED UNDER SCHEME A

OIML Issuing Authority
Name: FORCE Certification A/S Address: Park Allé 345, 2605 Brøndby, Denmark Person responsible: Per Rafn Crety
Applicant
Name: Tunaylar Baskül Sanayi ve Ticaret A.Ş. Address: Akçaburgaz Mah. 3124 Sok. No:10 Esenyurt - İstanbul Turkey
Manufacturer Tunaylar Baskül Sanayi ve Ticaret A.Ş.
Identification of the certified type (the detailed characteristics will be defined in the additional pages) LL2/AW
Designation of the module (if applicable) Automatic instrument for weighing road vehicles in motion
This OIML Certificate attests the conformity of the above identified type (represented by the sample(s) identified in the OIML type evaluation report) with the requirements of the following Recommendation of the International Organization of Legal Metrology(OIML):
OIML R134-1, Edition(year):2006
For accuracy class(if applicable):1 or 2-total weight C or D or E-single axle load B or C or D or E-axle group load
OIML Certificate No.R134/2006-A-DK2-24.01 Revision 1
This OIML Certificate relates only to metrological and technical characteristics of the type of measuring instrument covered by the relevant OIML Recommendation identified above.This OIML Certificate does not bestow any form of legal international approval.
The conformity was established by the results of tests and examinations provided in the associated OIML reports:Type examination report:No.DANAK-199782,dated 14 October 2005,that includes 76 pagesType examination report:No.DANAK-1910532,dated 27 May 2009,that includes 66 pagesType examination report:No.DANAK-1913637,dated 03 December 2013,that includes 52 pagesType evaluation report:No.124-22951.90.10 rev.1,dated 04 April 2024,that includes 12 pages
The technical documentation relating to the identified type is contained in documentation file:124-22951.90.10OIML Certificate History
Revision No.DateDescription of the modification
Initial version27 February 2024-
113 February 2025Type evaluation report revised
Identification, signature and stampThe OIML Issuing AuthorityFORCE Certification A/SDate:13 February 2025Jens Hovgård Jensen2025-02-13Digitally signed by Jens Hovgård Jensenjhje@force.dkCertification ManagerJens Hovgård JensenCertification Manager
Important note: Apart from the mention of the Certificate's reference number and the name of theOIML Member State in which the Certificate is issued,partial quotation of theCertificate and of the associated OIML type evaluation report(s) is not permitted,although either may be reproduced in full.

Descriptive annex

Characteristics

Accuracy class, total weight12
Accuracy class, single axle loadC or DC or D or E
Accuracy class, axle-group loadB or C or DC or D or E
Maximum capacityMax≤30000kg
Minimum capacityMin≥50×d≥10×d
Scale intervald≤20kg≤50kg
Number of verification scale intervalsn500≤n≤300050≤n≤1000
Maximum operation speedVmax9km/h
Minimum operation speedVmin1km/h
Maximum transit speed:30km/h
Maximum number of axles:amax15
Direction of traveldual
Scale interval for stationary loadE≥0.8μV
Power supply voltage:12VDC
Connected load cellsShall comply withR60
Temperature range for the indicator-10℃/+40℃
Software version forLL2/AW1.93.xx

tification Syst

Interfaces

2×RS232/RS422/RS485

Load cells

The instrument uses one load cell type Flintec PC1 C3 $ \left( E_{\mathrm{m a x}}=30 \mathrm{~kg} \right) $ located in the centre of the weighing conveyor.

Any analogue load cells may be used for this instrument provided the following conditions are met:

  1. There is an OIML Certificate of Conformity (R60:2000 or R60:2017) issued for the load cell

  2. The certificate contains the load cell types and the necessary load cell data required for the manufacturer's declaration of compatibility of modules (OIML R76:2006 Annex F), and any particular installation requirements. A load cell marked NH is allowed only if humidity testing to OIML R76:2006 has been conducted on this load cell.

  3. The compatibility of load cells and indicator is established by the manufacturer by means of the compatibility of modules form, according to OIML R76:2006 Annex F.

  4. The load cell transmission must be a standard, non-critical design.

Sealing Measures

The indicator and the junction box for load cells shall be sealed against access to their internal by sealing using wire and seal or tamper-evident stickers.

Detachable load cell connectors shall be sealed using tamper-evident stickers.