Skip to content

← R117

R117/2019-A-NL1-25.03 Rev. 0

Applicant
FAURE HERMAN
Issuer
NL1
Issuing year
2025
Status
Valid

Source PDF (certificates/R117/2019/r117-2019-nl1-2025-03-rev0.pdf) · extracted by OCR from the digitalized tier of the corpus.

R117/2019-A-NL1-25.03 Rev. 0

OIML Certificate

OIML Member State The Netherlands

Number R117/2019-A-NL1-25.03 revision 0

Project number 3687257

Page 1 of 4

Issuing authority NMi Certin B.V. Person responsible: M.Ph.D. Schmidt

Applicant and FAURE HERMAN

Manufacturer 2 Lieu-Dit l'Archette

72400 La Ferté Bernard

France

Identification of the certified type

A measuring device (ultrasonic flow meter) intended to be used as part of an interruptible or non- interruptible dynamic measuring system for liquids other than water.

Type:

FH-SONIC

Characteristics See following page(s)

This OIML Certificate is issued under scheme A.

This Certificate attests the conformity of the above identified type (represented by the sample(s) identified in the OIML Type Evaluation Report) with the requirements of the following Recommendation of the International Organization of Legal Metrology (OIML):

R 117-1:2019 "Dynamic measuring systems for liquids other than water"

Accuracy class 0,3,0,5 and 1,0

This Certificate relates only to the metrological and technical characteristics of the type of measuring instrument covered by the relevant OIML International Recommendation identified above. This Certificate does not bestow any form of legal international approval.

Important note: Apart from the mention of the Certificate's reference number and the name of the OIML Member State in which the Certificate was issued, partial quotation of the Certificate and of the associated OIML Type Evaluation Report(s) is not permitted, although either may be reproduced in full.

Issuing Authority

NMi Certin B.V., OIML Issuing Authority NL1 4 March 2025

Certification Board

This document is issued under the provision that no liability is accepted and that the applicant shall indemnify third-party liability.

OIML Certificate

Number R117/2019-A-NL1-25.03 revision 0 Project number 3687257 Page 2 of 4

  • No. NMi-3687257-01 dated 4 March 2025 that includes 45 pages;

The conformity was established by the results of tests and examinations provided in the associated report(s):

  • No. NMi-3687257-02 dated 4 March 2025 that includes 32 pages.

General information about the measuring device

The FH-SONIC is an ultrasonic flow meter for measuring the actual flowing volume of liquid products. It is based on the measurement of the runtimes of ultrasonic pulses along several measuring paths. The meter consists of the following assemblies:

  • One meter body with a straight pipe section with 5 ultrasonic measuring paths;

  • Two ultrasonic transducers per measuring path, where the two transducers both serve as transmitters and receivers;

  • The electronics which are separated from the meter body with the measurement electronics for excitation and processing of the transducer signals and the interface electronic.

Characteristics of the measuring instrument

In Table 1 the general characteristics of the measuring instrument are presented. The construction of the measuring instrument is recorded in the Documentation folder no. TC12652-1.

OIML Certificate

OIML Member State The Netherlands

Number R117/2019-A-NL1-25.03 revision 0

Project number 3687257

Page 3 of 4

Table 1 General characteristics

Number of sound paths5 Horizontal (measurements) + 1 Vertical (diagnostics)
Sound frequencyAround 1 MHz
Path angle45°, except for path 2 and 4 of the DN200(8") size which have a path angle of 71°
Approved quantityVolume at flowing conditions
Maximum pressure20 bar(g)
Environmental classesM2/E2 Humidity class H3: Condensing, open location
Ambient temperature range-40...+55℃
Product temperature range-40...+35℃
Intended for the measurement ofLiquid petroleum and related products, liquids food and chemical products in liquid state with a maximum viscosity of 200mPa·s.
Power supply voltage24V DC
Flow characteristicsSee table 2
Approved inputs-
Approved outputsDual pulse output(maximum frequency is 10kHz)
Software identificationSee table 3

Table 2 Characteristics of the family of instruments

Meter sizeQminQmaxMinimum measured quantityMinimum Reynolds Number
[DN][Inch][m3/h][m3][m3][-]
200853139425000
2501092219855000
30012130312055000
35014157377055000
40016205492556000
45018258623556000

OIML Certificate

OIML Member State The Netherlands

Number R117/2019-A-NL1-25.03 revision 0 Project number 3687257

Page 4 of 4

Table 3 Software identification

IdentificationVersionChecksum
Flow Calc. board MID SoftwareMID-1.387e3d1de
Ultrasound board MID SoftwareMID-1.379f92988
FPGA Software (Ultrasound boards)24-12-18 ind 99-

Certificate history:

RevisionDateDescription of the modification
04 March 2025Initial release