Skip to content

← R117

R117/2019-A-NL1-21.08 Rev. 1

Applicant
CZAR Metric System Private Limited
Issuer
NL1
Issuing year
2023
Status
Valid

Source PDF (certificates/R117/2019/r117-2019-nl1-2021-08-rev1.pdf) · extracted by OCR from the digitalized tier of the corpus.

R117/2019-A-NL1-21.08 Rev. 1

OIML Certificate

OIML Member State The Netherlands

Number R117/2019-A-NL1-21.08 revision 1 Project number 2502536 Page 1 of 7

Issuing authority Person responsible:

NMi Certin B.V.

M.Ph.D. Schmidt

Applicant and Manufacturer

CZAR Metric System Private Limited Plot No. A-451 MIDC Industrial Area, Mahape Navi Mumbai 400710 Maharashtra, India

Identification of the certified type

A fuel dispenser (liquids other than water) Type: CZF-*******[1]

Characteristics See page 2 and further

This OIML Certificate is issued under scheme A.

This Certificate attests the conformity of the above identified type (represented by the samples identified in the OIML Type Evaluation Report) with the requirements of the following Recommendation of the International Organization of Legal Metrology (OIML):

R 117:2019 "Dynamic measuring systems for liquids other than water"

Accuracy class 0,5

This Certificate relates only to the metrological and technical characteristics of the type of measuring instrument covered by the relevant OIML International Recommendation identified above. This Certificate does not bestow any form of legal international approval.

Important note: Apart from the mention of the Certificate's reference number and the name of the OIML Member State in which the Certificate was issued, partial quotation of the Certificate and of the associated OIML Type Evaluation Reports is not permitted, although either may be reproduced in full.

[1] Where " $ ^{*} $ " can be a number or a letter for representing different configurations of the dispenser.

OIML Certificate

OIML Member State The Netherlands

Number R117/2019-A-NL1-21.08 revision 1 Project number 2502536 Page 2 of 7

The conformity was established by the results of tests and examinations provided in the associated reports:

  • No. NMi-2502536-01 dated 27 October 2021 that includes 119 pages;

  • No. NMi-2502536-03 dated 4 May 2023 that includes 34 pages.

Fuel Dispenser CZF-******* series

Characteristics of the fuel dispenser

In Table 1 the general characteristics of the fuel dispenser are presented. The construction of the fuel dispenser is recorded in the Documentation folder no. DISP2502536-1.

Table 1 General characteristics of fuel dispenser

Manufacturer's trademarkCZAR Metric System Private Limited
Type designationCZF-*****
Accuracy class0,5
Instrument TypeFuel dispenser (Liquid other than water)
Essential parts of the dispenserElectronic calculating and indicating device - CZ series - Pulser CZ-MGE-XX Measurement transducer - Piston meter CZ-FM120 (for fuel and AdBlue) Gas separator in combination with the pumping unit - Vane suction pump CZ-VP080
Approved for liquid productsGasoline; Blended Gasoline with up to 100% ethanol or 20% methanol or 20% MTBE; Diesel, Biodiesel (up to 100% fame B100); Blended Bio-Diesel 10%~60%, Kerosene and AdBlue/DEF (Diesel Exhaust Fuel).
Maximum number of nozzles8
Maximum number of main indicating device4
Maximum number of nozzles connected to each indicating device4
Environment classesE1/H3/M2
Flow characteristicsrefer table 2 for details.
Ambient temperature range-25℃...+55℃
Liquid temperature range-5℃...+35℃
Approved density range710...1200kg/m3

OIML Certificate

OIML Member State The Netherlands

Number R117/2019-A-NL1-21.08 revision 1

Project number 2502536

Page 3 of 7

Maximum pressure3,5 bar(g)
Electrical power230VAC/50Hz
Identification of softwarerefer table4 for details.

Table 2 Flow characteristics of fuel dispenser

Model typeQmin[L/min]Qmax[L/min]MMQ[L]
Fuel dispenserStandard duty-Single CZ-FM120 flowmeter2402
Fuel dispenserHeavy duty-Single CZ-FM120 flowmeter2802
Fuel dispenserUltra-Heavy duty-two parallel CZ-FM120 flowmeter[1]51305
AdBlue dispenserStandard duty-Single CZ-FM120 flowmeter4402

[1] The $ Q_{\mathrm{min}} $ flowrate through each individual flow meters in the parallel configuration shall not be smaller than the $ Q_{\mathrm{min}} $ of the individual meter (2 L/min);

The $ Q_{\mathrm{m a x}} $ flowrate through each individual flow meters in the parallel configuration shall not be greater than the $ Q_{\mathrm{m a x}} $ of the individual meter (80 L/min).

Each CZF-******* dispenser consists at least of:

  • One combined vane pump and gas eliminator device (CZ-VP080);

A gas separator is not essential if submersible pump is used, in this case measures should be taken on the supply tank to make sure that air or gas is not introduced in the system.

  • One measurement transducer (piston meter (CZ-FM120)) with magnetic encoder (pulser (CZ-MGF-XX)).

  • One electronic calculating/indicating device (CZ series calculator).

  • Optionally, a printer may be connected to the dispenser as follows:

  • Printer mounted on the dispenser door, powered and communication through the dispenser;

  • Printer mounted on the side of the dispenser, powered and communication through the dispenser;

  • Remote printer connected via the POS communication cable.

The fuel dispenser has an option for vapour recovery.

Optionally, an electro-magnetic totaliser (maximum volume indication 9999999 L) is also present on the dispenser.

The same housing of the dispenser can comprise of one or more measuring systems. When more than one measuring systems are in one housing, one calculating/indicating device may be a common part of the measuring systems.

The calculating/indicating device can have a maximum of 4 main displays, allowing it to configure and control 8 nozzles (meters), out of which 4 nozzles (meters) can be simultaneously operated.

OIML Certificate

OIML Member State The Netherlands

Number R117/2019-A-NL1-21.08 revision 1 Project number 2502536 Page 4 of 7

A maximum of four nozzles (meters) can be connected to each calculating/indicating device's main display, only one nozzle out of the four connected to a single display can be simultaneously operated.

Approved input - Pulser communication cable via RS-485

Approved output - POS communication cable via RS-485

All communication cables (POS and Pulser) should be shielded cables.

For standard and heavy-duty application, a single meter is used to deliver fuel through the hydraulic path for each nozzle.

For ultra-heavy-duty applications two meters are connected in parallel to deliver fuel through a single nozzle.

Essential parts of the CZF-******* series fuel dispensers

The conformity of the following parts was established by the results of tests and examinations provided in the associated report:

Part:

Calculating/indicating device

Producer:

CZAR Metric System Private Limited

Type:

CZ Series

Documentation folder:

DF2502536-2

Reports:

No. NMi-2502536-01 dated 27 October 2021 that includes 119 pages.

No. NMi-2502536-03 dated 4 May 2023 that includes 34 pages.

Table 3 General characteristics of the calculating/indicating device type CZ series

Maximum volume indication6 digits(4 integers and 2 decimals)
Maximum unit price5 digits(3 integers and 2 decimals)
Maximum price to pay7 digits(5 integers and 2 decimals)
Environmental classesE1/M2/H3(condensing humidity)
Ambient temperature range-25℃/+55℃
Power supply230VAC50Hz
Maximum number of nozzles8
Maximum number of main indicating device4
Maximum number of nozzles connected to each indicating device4
Approved inputPulser communication cable via RS-485(shielded)
Approved outputPOS communication cable via RS-485(shielded)
PulserMagnetic encoderCZ-MGE-XXRS-485 communication protocolOutput signal256 pulse/revolution

OIML Certificate

OIML Member State The Netherlands

Number R117/2019-A-NL1-21.08 revision 1 Project number 2502536 Page 5 of 7

Table 4 Software identification of the calculating/indicating device type CZ series

BoardFirmware versionHash code
CPU BoardCZ-CPU_V1.110f85e8d0d3add237df9c1066014cc550fcfb53174ae3e446ab6c116ab504a9f
CZ-CPU_V2.0414f8d096a229fb0d4823f91a9b4761e369a8e468389755b4d3544f2c0b0d08b
Main Display cum CPU BoardCZ-DIS_V1.11f2eda31bcef24f9427819d38460d1c47b0f4310f1227aae18c823b4d8634f3
CZ-DIS_V2.0d7a87432a2748161363ecdcd809d8c6c481953ff54f80bef77df88902c5bca8a
Pulser BoardCZ-MGE_V1.148680bb9633709cc27e18822df23f5b762831e83d946893fab5382aec716363c
Keypad Display BoardCZ-DKP_V1.18d0ea94278cafd43a4d949c8b1431c02d89665af02090496e4a3b7760181034a

Software version verification of the calculating/indicating device type CZ series The software versions and checksums can be displayed on the LCD display by following the below procedure:

On the alphanumeric keypad on the dispenser press SETUP $ \rightarrow $ P2 $ \rightarrow $ enter unique password by a user with sufficient rights $ \rightarrow $ ENTER this puts the dispenser in maintenance mode.

Then press 5 $ \rightarrow $ 1 $ \rightarrow $ 1 $ \rightarrow $ 1 for CPU board

or 5 $ \rightarrow $ 1 $ \rightarrow $ 1 $ \rightarrow $ 2 for Main Display board

or 5 $ \rightarrow $ 1 $ \rightarrow $ 1 $ \rightarrow $ 3 for Pulser board

or 5 $ \rightarrow $ 1 $ \rightarrow $ 1 $ \rightarrow $ 4 for Keypad Display board

Table 5 Legally relevant parameter list of the calculating/indicating device type CZ series

Process codeProcess code nameValue / range
122Unit Rate5 digits (XXX.XX)
212Product Grade3 Characters (XXX)
24521Pre-Mask Value60(mL)
2412Decimal Setting0~3(digits)
24511High Flow Cutoff250(mL)
243No Pulse No Fuel30(sec)
51LogTransaction, Calibration Change, Unit Rate Change, Density Change, Error
311View Last CalView K Factor
214Date & Timedd:mm:yy,hh:mm:ss

OIML Certificate

OIML Member State The Netherlands

Number R117/2019-A-NL1-21.08 revision 1

Project number 2502536

Page 6 of 7

Process codeProcess code nameValue / range
511PCBA Soft DetailView board details
52Model InfoView model details
521Serial NumberView serial number of Dispenser

Part:

Producer:

Measurement transducer

CZAR Metric System Private Limited

Type:

CZ-FM120

Documentation folder:

DISP2502536-1

Reports:

No. NMi-2502536-01 dated 27 October 2021that includes 119 pages.

Table 6 General characteristics of the measurement transducer type CZ-FM120

Flow meter typeMechanical 2-piston meter
Flow rate range [L/min]2-80L/min
MMQ2L
Maximum pressure3,5bar
Product temperature range-5℃/+35℃
Intended for the measurement ofGasoline;Blended Gasoline with up to 100% ethanol or 20% methanol or 20% MTBE;Diesel,Biodiesel(up to 100% fame B100);Blended Bio-Diesel10%~60%,Kerosene and AdBlue/DEF(Diesel Exhaust Fuel).
Approved density range710...1200kg/m3
PulserMagnetic encoderCZ-MGE-XXRS-485 communication protocolOutput signal256 pulse/revolution

OIML Member State The Netherlands

OIML Certificate

Number R117/2019-A-NL1-21.08 revision 1 Project number 2502536 Page 7 of 7

Part:

Producer:

Type:

Documentation folder:

Reports:

Gas elimination device

CZAR Metric System Private Limited

CZ-VP080

DISP2502536-1

No. NMi-2502536-01 dated 27 October 2021 that includes 119 pages.

Table 7 General characteristics of the gas elimination device type CZ-VP080

The gas separator is in combination with the pumping unit. The pump type CZ-VP080 is a vane suction pump. The attached gas separator to the pumping unit is a float type mechanical device.

Maximum flow rate80L/min
Maximum pressure3.5bar
Product temperature range-5℃/+35℃

Production location

The fuel dispenser is produced at one of the following production locations:

  • CZAR Metric System Private Limited, Plot No. A-451, Central Road, MIDC Industrial Area,

  • Mahape Pin code 400710, Maharashtra India.

  • CZAR Metric System Private Limited, Plot No.C-541, MIDC Industrial Area, Pawne Navi Mumbai 400705, Maharashtra, India.

Certificate history:

This revision replaces the previous version.

RevisionDateDescription of the modification
Initial27 October 2021-
14 May 2023Approved printer mounted on the dispenser as a mandatory ancillary device