Skip to content

← R117

R117/2019-A-NL1-21.02 Rev. 6

Applicant
Gilbarco Veeder Root PDP Manufacturing Facility
Issuer
NL1
Issuing year
2026
Status
Valid

Source PDF (certificates/R117/2019/r117-2019-nl1-2021-02-rev6.pdf) · extracted by OCR from the digitalized tier of the corpus.

R117/2019-A-NL1-21.02 Rev. 6

OIML Certificate

OIML Member State The Netherlands

Number R 117/2019-A-NL1-21.02 revision 6 Project number 4020038 Page 1 of 10

Issuing authority NMi Certin B.V. Person responsible: M.Ph.D. Schmidt

Applicant and Gilbarco Veeder Root India Pvt. Ltd.

Manufacturer PDP Manufacturing Facility

SF NO.-628/2 & 627/2,W4- Coimbatore Campus

Eachanari, Chetipalayam Road

Malumichampatti, Coimbatore

Tamilnadu 641021

India

Identification of the certified type

A fuel dispenser and/or Aqueous Urea Solution (AUS) dispenser Type: Sprint and/or Frontier

Characteristics See following page(s)

This OIML Certificate is issued under scheme A.

This Certificate attests the conformity of the above identified type (represented by the sample(s) identified in the OIML Type Evaluation Report) with the requirements of the following Recommendation of the International Organization of Legal Metrology (OIML):

R 117-1:2019 "Dynamic measuring systems for liquids other than water"

Accuracy class 0,5

This Certificate relates only to the metrological and technical characteristics of the type of measuring instrument covered by the relevant OIML International Recommendation identified above. This Certificate does not bestow any form of legal international approval.

This certificate and supporting reports comply with the requirements of OIML-CS-PD-07 clause 6.2.

Important note: Apart from the mention of the Certificate's reference number and the name of the OIML Member State in which the Certificate was issued, partial quotation of the Certificate and of the associated OIML Type Evaluation Report(s) is not permitted, although either may be reproduced in full.

Issuing Authority

NMi Certin B.V., OIML Issuing Authority NL1 2 February 2026

NMi Certin B.V.

Thijsseweg 11

2629 JA Delft

the Netherlands

T +31 88 636 2332

certin@nmi.nl

www.nmi.nl

Certification Board

This document is issued under the provision that no liability is accepted and that the applicant shall indemnify third-party liability.

The notification of NMi Certin B.V. as Issuing Authority can be verified at www.oiml.org

This document is digitally signed and sealed. The digital signature can be verified in the blue ribbon at the top of the electronic version of this certificate.

OIML Certificate

Number R 117/2019-A-NL1-21.02 revision 6 Project number 4020038 Page 2 of 10

The conformity was established by the results of tests and examinations provided in the associated report(s):

For evaluation of the complete fuel dispenser:

  • NMi-2550303-01 dated 29 January 2021 that includes 65 pages.

For the mechanical meter sensors, brand Gilbarco Veeder-Root and type C+, V and V+ meter:

  • CVN-10119469 dated 2 March 2001 that includes 56 pages;

  • CVN-202211 dated 16 May 2003 that includes 49 pages;

  • TR:1327 dated 15 April 2015 that includes 12 pages;

  • TR:0561 dated 22 October 2009 that includes 14 pages;

  • TR:0587 dated 29 September 2010 that includes 14 pages;

  • TR:748 dated 10 May 2017 that includes 10 pages.

For the electromagnetic measurement sensors, brand KROHNE and type BATCHFLUX 3200 C:

  • NMi-16200528-01 dated 19 August 2016 that includes 46 pages;

  • NMi-16200528-02 dated 19 August 2016 that includes 20 pages;

  • NMi-1901321-01 dated 27 July 2017 that includes 9 pages.

For the electronic calculating and indicating device, brand Gilbarco Veeder-Root and type Tulip:

  • NMi-2475566-01 dated 3 December 2020 that includes 83 pages;

  • NMi-2475566-02 dated 14 December 2020 that includes 28 pages;

  • NMi-2630143-01 dated 9 March 2022 that includes 49 pages;

  • NMi-3619014-01 dated 20 November 2023 that includes 13 pages;

  • NMi-3802158-01 dated 29 July 2024 that includes 13 pages;

  • NMi-4020038-01 dated 2 February 2026 that includes 12 pages;

  • SN:1386 dated 9 August 2017 that includes 22 pages;

  • SN:1410 dated 1 December 2017 that includes 23 pages;

  • SN:1438 dated 20 December 2018 that includes 22 pages;

  • SN:1441 dated 24 January 2019 that includes 4 pages;

  • SN:1450 dated 12 July 2019 that includes 24 pages;

For the electronic calculating and indicating device, brand Gilbarco Veeder-Root, type Apollo-II and/or Apollo-Astra:

  • NMi-2418116-01 dated 6 March 2020 that includes 112 pages;

  • NMi-2418116-02 dated 6 March 2020 that includes 27 pages;

  • NMi-2461432-01 dated 11 September 2020 that includes 90 pages;

  • NMi-2509634-01 dated 4 February 2021 that includes 80 pages;

  • NMi-3465234-01 dated 10 October 2022 that includes 14 pages;

  • NMi-3733342-01 dated 7 May 2024 that includes 33 pages;

  • NMi-3828209-01 dated 27 June 2025 that includes 22 pages.

For the gas separator, brand Gilbarco Veeder-Root and type GPU90

  • NMi-3885366-01 dated 26 April 2025 that includes 24 pages;

  • TR:740 dated 24 February 2017 that includes 11 pages;

  • R117/1995-NL1-04.04 dated 24 January 2005 that includes 50 pages

OIML Certificate

OIML Member State The Netherlands

Number R 117/2019-A-NL1-21.02 revision 6 Project number 4020038

Page 3 of 10

Characteristics of the dispenser

In Table 1 the general characteristics of the measuring instrument are presented.

The construction of the measuring instrument is recorded under the type evaluation reports mentioned here above and the documentation folder number NMi-2550303-01-5.

Table 1 General characteristics

Fuel dispenserAUS dispenser
Minimum-maximum flow rate1,6-40L/minViscosity range0,4-1,0mPa·s.2-40L/min
2,0-80L/minViscosity range1,1-8,0mPa·s.
Minimum measured quantity2,5and10L2L
Maximum pressure3,5bar(g)10bar(g)
Accuracy class0,50,5
Environmental classesM1/E1M1/E1
Ambient temperature range-25-+55℃-10-+55℃
Product temperature range-25-+50℃-10-+40℃
Intended for the measurement ofHydrocarbon oils(Gasoline,Gasoline up to 86% ethanol orMTBE,Gasoline up to 5% methanol,Diesel or Biodiesel up to 100%)Aqueous Urea Solution(AUS) dispenser

Each measuring system consists at least of:

  • One combined pump and gas eliminator device (gas separator);

  • If no gas separator (*) is used on the measurement system, provision shall be taken to prevent gas passing through the meter sensor.

  • One or more meter sensor (meter);

  • One calculating/indicating device (calculator).

The characteristics of the mentioned parts of the fuel/AUS dispenser are presented at table 2 and higher.

The dispenser can be equipped with optional features and functions listed, see documentation number 2550303-01/2-02. Utilizing these features and functions do not have impact on the metrological data and functioning of the dispenser.

The same housing of the dispenser can comprise of one or more measuring systems. When more than one measuring systems are in one housing, one calculating/indicating device may be a common part of the measuring systems.

For multi-product dispensers it is only possible to deliver one product at the same time on one side of the dispenser.

OIML Certificate

OIML Member State The Netherlands

Number R 117/2019-A-NL1-21.02 revision 6 Project number 4020038

The maximum flowrate once installed may be limited, but for fuels shall be greater than 10 times the minimum flowrate. For Aqueous Urea Solution (AUS) dispenser the maximum flowrate shall be greater than 5 times the minimum flowrate.

Page 4 of 10

Table 2 gives an overview of flow characteristics of the configurations of the family of instruments.

Table 2 Flow characteristics of the configurations

Configuration fuel dispenserFlow rate rangeRemarks
1x gas separator*1x meter sensor,type C+,V or V+1,6-40L/minIntended for the measurement of hydrocarbon oils with viscosity range0,4-1,0mPa·s.
1x gas separator*1x meter sensor,type C+,V or V+2,0-80L/minIntended for the measurement of hydrocarbon oils with viscosity range1,1-8,0mPa·s.Optionally a feature to allowQmax to be limited to40L/min.
1x gas separator*2x meter sensors,type C+,V or V+,one per dispenser side1,6-40L/minIntended for the measurement of hydrocarbon oils with viscosity range0,4-1,0mPa·s.The gas separator of this measuring system is suitable for use with two meter sensors.Each meter sensor is considered as part of an individual measuring system.Flowrate reduces to40L/min with both meter sensors operating.Optionally a feature to allowQmax to be limited to40L/min with a single meter sensor operating.
1x gas separator*2x meter sensors,type C+,V or V+,one per dispenser side2,0-80L/minIntended for the measurement of hydrocarbon oils with viscosity range1,1-8,0mPa·s.The gas separator of this measuring system is suitable for use with two meter sensors.Each meter sensor is considered as part of an individual measuring system.Flowrate reduces to40L/min with both meter sensors operating.
2x gas separators*2x meter sensors,type C+,V or V+2,0-130L/minIntended for the measurement of hydrocarbon oils with viscosity range1,1-8,0mPa·s.AQmax of130L/min is reached by connecting two gas separators and two meter sensors in parallel with delivery through a single transfer point.Optionally a feature to allowQmax to be limited to80L/min.Optionally a feature to allow one of the gas separators and one of the meter sensors to operate as the configuration described above.

OIML Certificate

OIML Member State The Netherlands

Number R 117/2019-A-NL1-21.02 revision 6

Project number 4020038

Page 5 of 10

Configuration AUS dispenserFlow rate rangeRemarks
1x measurement sensor type KROHNE BATCHFLUX 3200C2-40L/minIntended for the measurement of Aqueous Urea Solution(AUS) dispenser

Parts of the measuring system

The conformity of the following parts was established by the results of tests and examinations provided in the associated report(s):

Part: Measurement sensor

Producer: Gilbarco Veeder Root

Type: C+

Reports: No. CVN-10119469 dated 2 March 2001 that includes 56 pages;

No. CVN-202211 dated 16 May 2003 that includes 49 pages;

No. TR:1327 dated 15 April 2015 that includes 12 pages;

No. TR:748 dated 10 May 2017 that includes 10 pages.

Table 3 General characteristics of the measurement sensor type C+

Flow rate range[L/min]1,6-40L/min2,0-80L/min
Intended for the measurement ofHydrocarbon oils with a viscosity of0,4mPa·s-1,0mPa·sHydrocarbon oils with a viscosity of1,1mPa·s-8,0mPa·s
MMQ1L1L
Maximum pressure3,5bar3,5bar
Environmental classesM1/E1M1/E1
Ambient temperature range-40℃/+55℃-40℃/+55℃
Product temperature range-40℃/+50℃-40℃/+50℃

Part: Measurement sensor

Producer: Gilbarco Veeder Root

Type: V, V+

Reports: No. TR:0561 dated 22 October 2009 that includes 14 pages;

No. TR:0587 dated 29 September 2010 that includes 14 pages.

Table 4 General characteristics of the measurement sensor type V and V+

Flow rate range[L/min]1,6-40L/min2,0-80L/min
Intended for the measurement ofHydrocarbon oils with a viscosity of0,4mPa·s-1,0mPa·sHydrocarbon oils with a viscosity of1,1mPa·s-8,0mPa·s
MMQ2L2L

OIML Certificate

OIML Member State The Netherlands

Number R 117/2019-A-NL1-21.02 revision 6 Project number 4020038

Page 6 of 10

Maximum pressure3,5 bar3,5 bar
Environmental classesM1/E1M1/E1
Ambient temperature range-25℃/+55℃-25℃/+55℃
Product temperature range-25℃/+50℃-25℃/+50℃

Part:

Producer:

Type:

Measurement sensor

KROHNE Altometer

BATCHFLUX 3200 C

Reports:

No. NMi-16200528-01 dated 19 August 2016 that includes 46 pages;

No. NMi-16200528-02 dated 19 August 2016 that includes 20 pages;

No. NMi-1901321-01 dated 27 July 2017 that includes 9 pages.

Table 5 General characteristics of the measurement sensor type BATCHFLUX 3200 C

Meter sizeDN15
Flow rate range [L/min]2-40L/min
Intended for the measurement ofAqueous Urea Solution (AUS)/Diesel Exhaust Fluid (DEF)
MMQ2L
Maximum pressure10bar
Environmental classesM1/E1
Ambient temperature range-40℃/+55℃
Product temperature range-40℃/+55℃
Software versionER1.0.0_/ER1.0.1_
Checksum6C3F9F91/C019A476
Power supply20,4-27,6VDC(grounding mandatory)

AUS/DEF is only suitable for dispensing between $ - 1 0 , \mathrm{^o C} / + 4 0 , \mathrm{^o C}. $

The BATCHFLUX 3200 C meter body is mounted with an Pt1000 temperature sensor close to the measurement tube. The temperature sensor parameter should be set in units Kelvin (K) whilst the low cut-off value should be not higher than 20% of the defined minimum flowrate in units L/min. The BATCHFLUX 3200 C meter communication protocol is optionally connected with the type Tulip calculating and indicating device via a secure protocol converter device.

Part: Calculating/indicating device

Producer: Gilbarco Veeder Root

Type: Tulip

Documentation folder: TC11938-4

Reports:

No. NMi-2630143-01 dated 10 March 2022 that includes 60 pages.

No. NMi-2475566-01 dated 3 December 2020 that includes 83 pages;

No. NMi-2475566-02 dated 14 December 2020 that includes 28 pages;

No. Sn:1386 dated 9 August 2017 that includes 22 pages;

No. Sn:1410 dated 1 December 2017 that includes 23 pages;

OIML Certificate

Number R 117/2019-A-NL1-21.02 revision 6 Project number 4020038 Page 7 of 10

No. Sn:1438 dated 20 December 2018 that includes 22 pages;

No. Sn:1441 dated 24 January 2019 that includes 4 pages;

No. Sn:1450 dated 12 July 2019 that includes 24 pages;

No. NMi-3619014-01 dated 16 November 2023 that includes 33 pages;

No. NMi-3802158-01 dated 29 July 2024 that includes 35 pages;

No. NMi-4020038-01 dated 2 February 2026 that includes 12 pages.

Table 6 General characteristics of the calculating/indicating device type Tulip

Maximum volume indication7 digits(9999999; floating decimal)
Maximum unit price6 digits(9999999; floating decimal)
Maximum price to pay7 digits(9999999; floating decimal)
Environmental classesM1/E1
Ambient temperature range-25℃/+55℃
Impulse encoder or pulserST73662 and Evole 2.1

Software version and Checksum of the calculating/indicating device type Tulip

Software versionsCRC ChecksumSoftware versionsCRC Checksum
901.04.5450x8C114CBE901.06.6200xB61794B3
901.06.500335B73FF
902.05.4720xE019F628902.06.3750x214A1AAC
902.05.4900x18D01F24902.06.5600xE5639B1D
902.05.4970x5332D24C902.06.6200xB61794B3
902.05.4980x535251C0902.08.6150xD7A29CB6
902.05.5100xC1028D71902.09.5550x4314D193
902.05.5300xBFC1F735
902.05.5500xD448AAB6
903.04.4900xC28DE814903.05.4970xBEA6E297
903.05.4720x44B55D1E
903.05.4950x7867485B
904.05.4950x97A9F34D
905.04.4900xF69315FD
906.04.4900x78E22785906.06.00219A8F60A

OIML Certificate

OIML Member State The Netherlands

Number R 117/2019-A-NL1-21.02 revision 6

Project number 4020038

Page 8 of 10

Software versionsCRC ChecksumSoftware versionsCRC Checksum
906.04.5100x16F14642906.06.4515776280E
906.05.4720x43D34A60906.06.5400x0DB37074
906.05.4900xA6CCA061906.06.5600x218E5D3D
906.05.4950xF1D37F83906.06.6250xB2F9AE82
906.05.4970x3E673E49
906.05.5300x4A2C7C8E
906.05.5500xCB527245
907.05.4900x480B6E5B907.06.6100x0CEBDE04
907.05.4950xC11BFB01907.08.6150xD7A29CB6
907.05.4970x70280013907.09.6050x804CE49C
907.05.5100x3CA99F60
907.05.5300x7E915697
907.05.6000xF0FA4226
907.05.6300x82BBF2B4
908.05.5510x4DBB2574

Calculating/indicating device

Apollo-II and/or Apollo-Astra

Documentation folder:

Reports:

NMi-2418116-01 dated 6 March 2020 that includes 112 pages.

NMi-2418116-02 dated 6 March 2020 that includes 27 pages.

NMi-2461432-01 dated 11 September 2020 that includes 90 pages.

NMi-2509634-01 dated 4 February 2021 that includes 80 pages.

NMi-3733342-01 dated 7 May 2024 that includes 33 pages.

NMi-3465234-01 dated 10 October 2022 that includes 14 pages.

NMi-3733342-01 dated 7 May 2024 that includes 33 pages.

NMi-3828209-01 dated 27 June 2025 that includes 22 pages.

Table 7 General characteristics of the calculating/indicating device type Apollo-II and/or Apollo-Astra

Maximum volume indication7 digits(9999999; floating decimal)
Maximum unit price6 digits(9999999; floating decimal)
Maximum price to pay7 digits(9999999; floating decimal)

OIML Certificate

OIML Member State The Netherlands

Number R 117/2019-A-NL1-21.02 revision 6

Project number 4020038

Page 9 of 10

Environmental classesM1/E1
Ambient temperature range-25℃/+55℃
Software identificationSee table below.
Impulse encoder or pulserSIP; SIP-II, Evole 2.1 and Astra Ex d pulser

Table 8 Software versions and checksum of the calculating/indicating device type Apollo-II

Software versionsCRC Checksum
A31.1.01 (displayed as A31101)8564
A31.1.02 (displayed as A31102)16D8
A31.1.03 (displayed as A31103)7090
A31.1.04 (displayed as A31104)1878
A31.1.05 (displayed as A31105)E89C
A31.1.06 (displayed as A31106)38F6
A31.1.07 (displayed as A31107)4D4E
A31.1.08 (displayed as A31108)D9C0
A31.1.10 (displayed as A31110)7C8E
A31.1.11 (displayed as A31111)7BA2
A31.1.12 (displayed as A31112)1644
A31.1.13 (displayed as A31113)335C
A31.1.14 (displayed as A31114)C784
A33.1.01 (displayed as A33101)1176
A33.1.02 (displayed as A33102)D572
A33.1.03 (displayed as A33103)B5FB
A33.1.04 (displayed as A33104)01AC

Table 9 Software versions and checksum of the calculating/indicating device type Apollo-Astra

Software versionsCRC Checksum
G01201F5B5

OIML Certificate

OIML Member State The Netherlands

Number R 117/2019-A-NL1-21.02 revision 6 Project number 4020038 Page 10 of 10

The software version number is indicated on the main display after powering up the calculator. After displaying the power up message "In APP": The Price display shows the word "APOLLO". The Volume display shows the software version. The price per unit display shows the 4-digit checksum.

Part:

Gas elimination device (gas separator)

Producer: Gilbarco Veeder Root

Type: GPU90

No. NMi-3885366-01 dated 26 April 2025 that includes 24 pages.

Reports:

No. TR:740 dated 24 February 2017 that includes 11 pages;

No. R117/1995-NL1-04.04 dated 24 January 2005 that includes 50 pages.

Table 10 General characteristics of the gas elimination device type GPU90

Maximum flow rate90 L/min
Minimum pressure1,4 bar
Maximum pressure3,0 bar
Environmental classesM1
Ambient temperature range-40℃/+55℃
Product temperature range-40℃/+50℃
Intended for the measurement oflow-viscosity mineral oils with a viscosity of0,4mPa·s-8,0mPa·s

Certificate history:

This revision replaces the previous version.

RevisionDateDescription of the modification
Initial29 January 2021-
110 March 2022The Tulip calculating and indicating device can be connected with the Krohne BATCHFLUX 3200C meter via a secured protocol converter device.
220 November 2023Tulip calculating and indicating device addition of new processor, PCB, new software and improved magnetic pulser
315 May 2024Name and address change
429 July 2024Addition of new electronics, new software and pulser and Apollo-Astra calculator
527 June 2025Addition of new hardware (Electromechanical totalizer and Keypad assembly) and software for Apollo-II calculator
62 February 2026Modification of hardware components and new software