R117/2019-A-NL1-20.02 Rev. 01
OIML Certificate
OIML Member State The Netherlands
Number R117/2019-A-NL1-20.02 Project number 2428030 Page 1 of 7
Issuing authority Person responsible:
NMi Certin B.V.
M. Boudewijns
Applicant and Manufacturer
Tatsuno India Pvt. Ltd.
B-31 & B-32 MIDC Industrial area, Taloja Dist.- Raigad 410208, Maharashtra, India
Identification of the certified type
A fuel dispenser (liquids other than water) Type: Sunny NexG series S** ******** [1]
Characteristics
See page 2 and further
This OIML Certificate is issued under scheme A.
This Certificate attests the conformity of the above identified type (represented by the sample(s) identified in the OIML Type Evaluation Report) with the requirements of the following Recommendation of the International Organization of Legal Metrology (OIML):
R 117:2019 "Dynamic measuring systems for liquids other than water"
Accuracy class 0,5
This Certificate relates only to the metrological and technical characteristics of the type of measuring instrument covered by the relevant OIML International Recommendation identified above. This Certificate does not bestow any form of legal international approval.
Important note: Apart from the mention of the Certificate's reference number and the name of the OIML Member State in which the Certificate was issued, partial quotation of the Certificate and of the associated OIML Type Evaluation Report(s) is not permitted, although either may be reproduced in full.
[1] Where " * " can be a number or a letter for representing different configurations of the dispenser.
Issuing Authority
NMi Certin B.V., OIML Issuing Authority NL1 1 December 2020
NMi Certin B.V.
Thijsseweg 11
2629 JA Delft
The Netherlands
T +31 88 636 2332
Certification Board
This document is issued under the provision that no liability is accepted and that the applicant shall indemnify third-party liability.
The notification of NMi Certin B.V. as Issuing Authority can be verified at www.oiml.org
This document is digitally signed and sealed. The digital signature can be verified in the blue ribbon at the top of the electronic version of this certificate.
OIML Certificate
OIML Member State The Netherlands
Number R117/2019-A-NL1-20.02 Project number 2428030 Page 2 of 7
The conformity was established by the results of tests and examinations provided in the associated report:
- No. NMi-2428030-01 dated 01 December 2020 that includes 143 pages.
Characteristics of the dispenser
In Table 1 the general characteristics of the dispenser are presented. The construction of the dispenser is recorded in the documentation folder no.2428030-1.
Table 1 General characteristics
| Manufacturer's trademark | Tatsuno India Pvt. Ltd. |
| Type designation | Sunny NexG series S** $******$ |
| Accuracy class | 0,5 |
| Instrument Type | Fuel dispenser (liquid other than water) |
| Essential parts of the dispenser | Electronic calculating and indicating device - Jisedai-1 - Pulsar EK-1117 Measurement transducer - Piston meter FF-1025 (for fuel and AdBlue) - Lobe meter FF-1006 (for fuel) Gas Separator in combination with the pumping unit - Integral suction pump FP1001 - Modular suction pump FP1022 |
| Approved for liquid products | Piston meter: Gasoline; Blended Gasoline with up to 85% ethanol or 20% methanol or 20% MTBE; Gasoline with Oil mix(Fixed/Variable) up to 9%; Diesel, Biodiesel (up to 100%); Kerosene; AdBlue/DEF & Additive. Lobe meter: Gasoline; Diesel. |
| Maximum number of nozzles | 8 |
| Environment classes | M2/E1/H3 |
| Ambient temperature range | -10℃...+55℃ |
| Liquid temperature range | -5℃...+35℃ |
| Density range | Piston meter:725...1200kg/m3 Lobe meter:725...925kg/m3 |
| Maximum pressure | 4 bar(g) |
| Electrical power calculator | 230VAC/50Hz |
OIML Certificate
OIML Member State The Netherlands
Number R117/2019-A-NL1-20.02
Project number 2428030
Page 3 of 7
| Identification of software | refer table 6 and 7 for details. |
Table 2 Flow characteristics
| Flow rate Range | Qmin[L/min] | Qmax[L/min] | MMQ[L] |
| Fuel Dispenser with Piston Meter(FF-1025)(Standard and heavy-duty application) | 3 | 80 | 2 |
| Fuel Dispenser with Lobe meter(FF-1006)(Ultra-heavy-duty application) | 14 | 180 | 10 |
Each dispenser consists at least of:
- One combined pump and gas eliminator device (gas separator (Integral suction pump FP-1006 or modular suction pump FP-1022)).
A gas separator is not essential if submersible pump is used, in this case measures should be taken on the supply tank to make sure that air or gas is not introduced in the system.
One measurement transducer (lobe meter (FF1006) or piston meter (FF-1025));
One electronic calculating/indicating device (Jisedai-1 calculator).
Optionally, a printer can be connected to the dispenser as follows:
Printer mounted on the dispenser door, powered and communication through the dispenser;
Printer mounted on the side of the dispenser, powered and communication through the dispenser;
Remote printer connected via the POS communication cable.
The fuel dispenser has an option for vapour recovery and additive injection.
Optionally, an electro-magnetic totaliser (maximum volume indication 9999999 L) is also present on the dispenser.
The same housing of the dispenser can comprise of one or more measuring systems. When more than one measuring systems are in one housing, one calculating/indicating device may be a common part of the measuring systems.
The calculating/indicating device can have a maximum of 4 main displays, allowing it to configure and control 8 nozzles (meters), out of which 4 nozzles (meters) can be simultaneously operated.
A maximum of two nozzles (meters) can be connected to each calculating/indicating device's main display, these two nozzles cannot be simultaneously operated.
Approved input-Pulser communication cable via RS-485
Approved output - POS communication cable via RS-485.
All communication cables (POS and Pulser) should be shielded cables and less than 10 meters in length.
A single meter is used to deliver fluid through the hydraulic path for each nozzle (no parallel or series meter combination).
The characteristics of the essential parts of the fuel dispenser are presented at table 3 and higher.
OIML Certificate
OIML Member State The Netherlands
Number R117/2019-A-NL1-20.02 Project number 2428030 Page 4 of 7
Essential parts of the dispenser
The conformity of the following parts was established by the results of tests and examinations provided in the associated report(s):
Part: Measurement transducer - Piston Meter
Producer: Tatsuno
Type: FF-1025
Documentation folder: 2428030-1
Reports: No. NMi-2428030-01 dated 01 December 2020 that includes 142 pages.
Table 3 General characteristics of the measurement transducer type FF-1025
| Flow rate range[L/min] | 3-80L/min |
| MMQ | 2L |
| Maximum pressure | 4 bars |
| Product temperature range | -5℃/+35℃ |
| Intended for the measurement of | Gasoline;Blended Gasoline with up to 85% ethanol or 20% methanol or 20% MTBE;Gasoline with Oil mix(Fixed/Variable)up to 9%;Diesel,Biodiesel(up to 100%);Kerosene;AdBlue/DEF&Additive. |
| Density range | 725 to 1200kg/m3 |
| Impulse encoder or pulser | Magnetic PulserEK-1117 |
Part: Measurement transducer - Lobe (Positive displacement) meter
Producer: Tatsuno
Type: FF-1006
Documentation folder: 2428030-1
Reports: No. NMi-2428030-01 dated 01 December 2020 that includes 142 pages.
Table 4 General characteristics of the measurement transducer type FF-1006
| Flow rate range[L/min] | 14-180L/min |
| MMQ | 10L |
| Maximum pressure | 4 bars |
| Product temperature range | -5℃/+35℃ |
| Intended for the measurement of | Gasoline and Diesel |
| Density range | 725 to 925kg/m3 |
| Impulse encoder or pulser | Magnetic Pulser EK-1117 |
OIML Certificate
OIML Member State The Netherlands
Number R117/2019-A-NL1-20.02
Project number 2428030
Page 5 of 7
Part:
Producer:
Calculating/indicating device
Type:
Tatsuno
Jisedai-1
Documentation folder:
2428030-1
Reports:
No. NMi-2428030-01 dated 01 December 2020 that includes 142 pages.
Table 5 General characteristics of the calculating/indicating device type Jisedai-1
| Maximum volume indication | 10 digits |
| Maximum unit price | 7 digits |
| Environmental classes | M2/E1/H3(Condensing Humidity) |
| Ambient temperature range | -10℃/+55℃ |
| Power supply | 230VAC50Hz |
| Maximum number of nozzles | 8 |
| Maximum number of main displays | 4 |
| Approved input | Pulser communication cable via RS-485 |
| Approved output | POS communication cable via RS-485 |
| Pulser | Magnetic Pulser EK-1117RS-485 communication protocolOutput signal2×50 pulse/revolution |
Table 6 Software identification
| Part | Firmware version | Hash code |
| Mother board | MB_1.1.0 | f4f9ccefc566e201d5dd5dd286d92020bff3cfd3c621a6dd5dd53e636ab1ae1f |
| Main display board | MD_1.1.0 | 7f1a64fe7b369543190b31f2ac1ee3cde6885dfc335ae43b86f4c5866eef4cec |
| Sub display board | SD_1.1.0 | ba60536000f058fa0834204603b0bde8f08f2344e1685a68a56842f00102e960 |
| Pulsar board | PB_1.1.0 | 18744262df949f491d31c85e9c050d03050c746cf4da3b213a892fb1517b27da |
The software versions and checksums can be displayed by following the below procedure: On the alphanumeric keypad on the dispenser press E $ \rightarrow $ E $ \rightarrow $ C $ \rightarrow $ E $ \rightarrow $ C $ \rightarrow $ select the 'OEM' or "RO" operator mode $ \rightarrow $ enter the OEM/RO password $ \rightarrow $ press "Enter Code" $ \rightarrow $ enter the code "99" $ \rightarrow $ select the bord for which the software version needs to be checked and press "ok".
OIML Certificate
OIML Member State The Netherlands
Number R117/2019-A-NL1-20.02
Project number 2428030
Page 6 of 7
Table 7 Legally relevant parameter list
| Process code | Process code name | Value / range |
| 13 | Unit Price | 7 digits |
| 20 | Product Code and Grade Selection | 1 to 15 |
| 21 | Rounding-Up Digit Position Setting | 1 to 7 |
| 32 | First Indication | 1 to 500 ml |
| 33 | Preset Volume Overshoot | 1 ml to 50 ml |
| 34 | Amount round Up | 0 to 9 digit |
| 36 | Volume Round Up | 0 to 9 digit |
| 37 | Decimal Set in Volume, Amount, Unit Price, Density And Totalizer Display | 0 to 3 digits |
| 38 | Monetary Unit Ratio | 1 to 100 |
| 44 | Slowdown Time For Pulse Stop | 1 to 99 sec |
| 45 | Pump Lock Time After Change Of Displayed Unit Price | 1 to 60 sec |
| 46 | Pulse Stop Motor Timeout | 1 to 600 sec |
| 47 | Dispenser Fueling Mode | should always be set to 1 during normal operation |
| 70 | Log View and Print | Parameter 70 (1 to 29) logs. Range of storing data is 0 to 999 |
| 79 | Calibration Mode | K factor range 95 to 100 |
| 81 | Reset Registration Data | |
| 95 | Date and Time Change | |
| 125 | Preset Timeout Setting | 0 to 30 sec at 5 sec intervals |
| 134 | Automatic Pump Lock Time | 1 to 600 sec |
OIML Certificate
OIML Member State The Netherlands
Number R117/2019-A-NL1-20.02
Project number 2428030
Page 7 of 7
Part: Gas elimination device in combination with integral pump
Producer: Tatsuno
Type: FP-1001
Documentation folder: 2428030-1
Reports: No. NMi-2428030-01 dated 01 December 2020 that includes 142 pages.
Table 8 General characteristics of the gas elimination device type FP-1001
The gas separator is in combination with the pumping unit.
The pump type FP-1001 is an Integral suction pump.
The attached gas separator to the pumping unit is a float type mechanical device.
The gas separator is identical to the gas separator attached to FP-1022 pump.
| Maximum flow rate | 180L/min |
| Maximum pressure | 4,0 bars |
| Product temperature range | -5℃/+35℃ |
Part: Gas elimination device in combination with modular pump
Producer: Tatsuno
Type: FP-1022
Documentation folder: 2428030-1
Reports: No. NMi-2428030-01 dated 01 December 2020 that includes 142 pages.
Table 9 General characteristics of the gas elimination device type FP-1022
The gas separator is in combination with the pumping unit.
The pump type FP-1022 is a Modular suction pump.
The attached gas separator to the pumping unit is a float type mechanical device.
The gas separator is identical to the gas separator attached to FP-1001 pump.
| Maximum flow rate | 180L/min |
| Maximum pressure | 4,0 bars |
| Product temperature range | -5℃/+35℃ |
Production location
The fuel dispenser is produced at one of the following production locations:
Tatsuno India Pvt. Ltd., B-31 & B-32 MIDC Industrial area, Taloja, Dist.- Raigad 410208 Maharashtra, India.
Tatsuno Corporation, Yokohama Plant: 1-1, Kasama 4-chome, Sakae-ku, Yokohama, Japan.
Tatsuno Engineering & Service Co. ltd, 19/79 Mu 18 Kukot lamlukka Pathumthani, 12130 Thailand.