Skip to content

← R117

R117/2019-A-NL1-20.02 Rev. 01

Applicant
Tatsuno India Private Limited
Issuer
NL1
Issuing year
2020
Status
Valid

Source PDF (certificates/R117/2019/r117-2019-nl1-2020-02-rev01.pdf) · extracted by OCR from the digitalized tier of the corpus.

R117/2019-A-NL1-20.02 Rev. 01

OIML Certificate

OIML Member State The Netherlands

Number R117/2019-A-NL1-20.02 Project number 2428030 Page 1 of 7

Issuing authority Person responsible:

NMi Certin B.V.

M. Boudewijns

Applicant and Manufacturer

Tatsuno India Pvt. Ltd.

B-31 & B-32 MIDC Industrial area, Taloja Dist.- Raigad 410208, Maharashtra, India

Identification of the certified type

A fuel dispenser (liquids other than water) Type: Sunny NexG series S** ******** [1]

Characteristics

See page 2 and further

This OIML Certificate is issued under scheme A.

This Certificate attests the conformity of the above identified type (represented by the sample(s) identified in the OIML Type Evaluation Report) with the requirements of the following Recommendation of the International Organization of Legal Metrology (OIML):

R 117:2019 "Dynamic measuring systems for liquids other than water"

Accuracy class 0,5

This Certificate relates only to the metrological and technical characteristics of the type of measuring instrument covered by the relevant OIML International Recommendation identified above. This Certificate does not bestow any form of legal international approval.

Important note: Apart from the mention of the Certificate's reference number and the name of the OIML Member State in which the Certificate was issued, partial quotation of the Certificate and of the associated OIML Type Evaluation Report(s) is not permitted, although either may be reproduced in full.

[1] Where " * " can be a number or a letter for representing different configurations of the dispenser.

Issuing Authority

NMi Certin B.V., OIML Issuing Authority NL1 1 December 2020

NMi Certin B.V.

Thijsseweg 11

2629 JA Delft

The Netherlands

T +31 88 636 2332

certin@nmi.nl

www.nmi.nl

Certification Board

This document is issued under the provision that no liability is accepted and that the applicant shall indemnify third-party liability.

The notification of NMi Certin B.V. as Issuing Authority can be verified at www.oiml.org

This document is digitally signed and sealed. The digital signature can be verified in the blue ribbon at the top of the electronic version of this certificate.

OIML Certificate

OIML Member State The Netherlands

Number R117/2019-A-NL1-20.02 Project number 2428030 Page 2 of 7

The conformity was established by the results of tests and examinations provided in the associated report:

  • No. NMi-2428030-01 dated 01 December 2020 that includes 143 pages.

Characteristics of the dispenser

In Table 1 the general characteristics of the dispenser are presented. The construction of the dispenser is recorded in the documentation folder no.2428030-1.

Table 1 General characteristics

Manufacturer's trademarkTatsuno India Pvt. Ltd.
Type designationSunny NexG series S** $******$
Accuracy class0,5
Instrument TypeFuel dispenser (liquid other than water)
Essential parts of the dispenserElectronic calculating and indicating device - Jisedai-1 - Pulsar EK-1117 Measurement transducer - Piston meter FF-1025 (for fuel and AdBlue) - Lobe meter FF-1006 (for fuel) Gas Separator in combination with the pumping unit - Integral suction pump FP1001 - Modular suction pump FP1022
Approved for liquid productsPiston meter: Gasoline; Blended Gasoline with up to 85% ethanol or 20% methanol or 20% MTBE; Gasoline with Oil mix(Fixed/Variable) up to 9%; Diesel, Biodiesel (up to 100%); Kerosene; AdBlue/DEF & Additive. Lobe meter: Gasoline; Diesel.
Maximum number of nozzles8
Environment classesM2/E1/H3
Ambient temperature range-10℃...+55℃
Liquid temperature range-5℃...+35℃
Density rangePiston meter:725...1200kg/m3 Lobe meter:725...925kg/m3
Maximum pressure4 bar(g)
Electrical power calculator230VAC/50Hz

OIML Certificate

OIML Member State The Netherlands

Number R117/2019-A-NL1-20.02

Project number 2428030

Page 3 of 7

Identification of softwarerefer table 6 and 7 for details.

Table 2 Flow characteristics

Flow rate RangeQmin[L/min]Qmax[L/min]MMQ[L]
Fuel Dispenser with Piston Meter(FF-1025)(Standard and heavy-duty application)3802
Fuel Dispenser with Lobe meter(FF-1006)(Ultra-heavy-duty application)1418010

Each dispenser consists at least of:

  • One combined pump and gas eliminator device (gas separator (Integral suction pump FP-1006 or modular suction pump FP-1022)).

A gas separator is not essential if submersible pump is used, in this case measures should be taken on the supply tank to make sure that air or gas is not introduced in the system.

  • One measurement transducer (lobe meter (FF1006) or piston meter (FF-1025));

  • One electronic calculating/indicating device (Jisedai-1 calculator).

Optionally, a printer can be connected to the dispenser as follows:

  • Printer mounted on the dispenser door, powered and communication through the dispenser;

  • Printer mounted on the side of the dispenser, powered and communication through the dispenser;

  • Remote printer connected via the POS communication cable.

The fuel dispenser has an option for vapour recovery and additive injection.

Optionally, an electro-magnetic totaliser (maximum volume indication 9999999 L) is also present on the dispenser.

The same housing of the dispenser can comprise of one or more measuring systems. When more than one measuring systems are in one housing, one calculating/indicating device may be a common part of the measuring systems.

The calculating/indicating device can have a maximum of 4 main displays, allowing it to configure and control 8 nozzles (meters), out of which 4 nozzles (meters) can be simultaneously operated.

A maximum of two nozzles (meters) can be connected to each calculating/indicating device's main display, these two nozzles cannot be simultaneously operated.

Approved input-Pulser communication cable via RS-485

Approved output - POS communication cable via RS-485.

All communication cables (POS and Pulser) should be shielded cables and less than 10 meters in length.

A single meter is used to deliver fluid through the hydraulic path for each nozzle (no parallel or series meter combination).

The characteristics of the essential parts of the fuel dispenser are presented at table 3 and higher.

OIML Certificate

OIML Member State The Netherlands

Number R117/2019-A-NL1-20.02 Project number 2428030 Page 4 of 7

Essential parts of the dispenser

The conformity of the following parts was established by the results of tests and examinations provided in the associated report(s):

Part: Measurement transducer - Piston Meter

Producer: Tatsuno

Type: FF-1025

Documentation folder: 2428030-1

Reports: No. NMi-2428030-01 dated 01 December 2020 that includes 142 pages.

Table 3 General characteristics of the measurement transducer type FF-1025

Flow rate range[L/min]3-80L/min
MMQ2L
Maximum pressure4 bars
Product temperature range-5℃/+35℃
Intended for the measurement ofGasoline;Blended Gasoline with up to 85% ethanol or 20% methanol or 20% MTBE;Gasoline with Oil mix(Fixed/Variable)up to 9%;Diesel,Biodiesel(up to 100%);Kerosene;AdBlue/DEF&Additive.
Density range725 to 1200kg/m3
Impulse encoder or pulserMagnetic PulserEK-1117

Part: Measurement transducer - Lobe (Positive displacement) meter

Producer: Tatsuno

Type: FF-1006

Documentation folder: 2428030-1

Reports: No. NMi-2428030-01 dated 01 December 2020 that includes 142 pages.

Table 4 General characteristics of the measurement transducer type FF-1006

Flow rate range[L/min]14-180L/min
MMQ10L
Maximum pressure4 bars
Product temperature range-5℃/+35℃
Intended for the measurement ofGasoline and Diesel
Density range725 to 925kg/m3
Impulse encoder or pulserMagnetic Pulser EK-1117

OIML Certificate

OIML Member State The Netherlands

Number R117/2019-A-NL1-20.02

Project number 2428030

Page 5 of 7

Part:

Producer:

Calculating/indicating device

Type:

Tatsuno

Jisedai-1

Documentation folder:

2428030-1

Reports:

No. NMi-2428030-01 dated 01 December 2020 that includes 142 pages.

Table 5 General characteristics of the calculating/indicating device type Jisedai-1

Maximum volume indication10 digits
Maximum unit price7 digits
Environmental classesM2/E1/H3(Condensing Humidity)
Ambient temperature range-10℃/+55℃
Power supply230VAC50Hz
Maximum number of nozzles8
Maximum number of main displays4
Approved inputPulser communication cable via RS-485
Approved outputPOS communication cable via RS-485
PulserMagnetic Pulser EK-1117RS-485 communication protocolOutput signal2×50 pulse/revolution

Table 6 Software identification

PartFirmware versionHash code
Mother boardMB_1.1.0f4f9ccefc566e201d5dd5dd286d92020bff3cfd3c621a6dd5dd53e636ab1ae1f
Main display boardMD_1.1.07f1a64fe7b369543190b31f2ac1ee3cde6885dfc335ae43b86f4c5866eef4cec
Sub display boardSD_1.1.0ba60536000f058fa0834204603b0bde8f08f2344e1685a68a56842f00102e960
Pulsar boardPB_1.1.018744262df949f491d31c85e9c050d03050c746cf4da3b213a892fb1517b27da

The software versions and checksums can be displayed by following the below procedure: On the alphanumeric keypad on the dispenser press E $ \rightarrow $ E $ \rightarrow $ C $ \rightarrow $ E $ \rightarrow $ C $ \rightarrow $ select the 'OEM' or "RO" operator mode $ \rightarrow $ enter the OEM/RO password $ \rightarrow $ press "Enter Code" $ \rightarrow $ enter the code "99" $ \rightarrow $ select the bord for which the software version needs to be checked and press "ok".

OIML Certificate

OIML Member State The Netherlands

Number R117/2019-A-NL1-20.02

Project number 2428030

Page 6 of 7

Table 7 Legally relevant parameter list

Process codeProcess code nameValue / range
13Unit Price7 digits
20Product Code and Grade Selection1 to 15
21Rounding-Up Digit Position Setting1 to 7
32First Indication1 to 500 ml
33Preset Volume Overshoot1 ml to 50 ml
34Amount round Up0 to 9 digit
36Volume Round Up0 to 9 digit
37Decimal Set in Volume, Amount, Unit Price, Density And Totalizer Display0 to 3 digits
38Monetary Unit Ratio1 to 100
44Slowdown Time For Pulse Stop1 to 99 sec
45Pump Lock Time After Change Of Displayed Unit Price1 to 60 sec
46Pulse Stop Motor Timeout1 to 600 sec
47Dispenser Fueling Modeshould always be set to 1 during normal operation
70Log View and PrintParameter 70 (1 to 29) logs. Range of storing data is 0 to 999
79Calibration ModeK factor range 95 to 100
81Reset Registration Data
95Date and Time Change
125Preset Timeout Setting0 to 30 sec at 5 sec intervals
134Automatic Pump Lock Time1 to 600 sec

OIML Certificate

OIML Member State The Netherlands

Number R117/2019-A-NL1-20.02

Project number 2428030

Page 7 of 7

Part: Gas elimination device in combination with integral pump

Producer: Tatsuno

Type: FP-1001

Documentation folder: 2428030-1

Reports: No. NMi-2428030-01 dated 01 December 2020 that includes 142 pages.

Table 8 General characteristics of the gas elimination device type FP-1001

The gas separator is in combination with the pumping unit.

The pump type FP-1001 is an Integral suction pump.

The attached gas separator to the pumping unit is a float type mechanical device.

The gas separator is identical to the gas separator attached to FP-1022 pump.

Maximum flow rate180L/min
Maximum pressure4,0 bars
Product temperature range-5℃/+35℃

Part: Gas elimination device in combination with modular pump

Producer: Tatsuno

Type: FP-1022

Documentation folder: 2428030-1

Reports: No. NMi-2428030-01 dated 01 December 2020 that includes 142 pages.

Table 9 General characteristics of the gas elimination device type FP-1022

The gas separator is in combination with the pumping unit.

The pump type FP-1022 is a Modular suction pump.

The attached gas separator to the pumping unit is a float type mechanical device.

The gas separator is identical to the gas separator attached to FP-1001 pump.

Maximum flow rate180L/min
Maximum pressure4,0 bars
Product temperature range-5℃/+35℃

Production location

The fuel dispenser is produced at one of the following production locations:

  • Tatsuno India Pvt. Ltd., B-31 & B-32 MIDC Industrial area, Taloja, Dist.- Raigad 410208 Maharashtra, India.

  • Tatsuno Corporation, Yokohama Plant: 1-1, Kasama 4-chome, Sakae-ku, Yokohama, Japan.

  • Tatsuno Engineering & Service Co. ltd, 19/79 Mu 18 Kukot lamlukka Pathumthani, 12130 Thailand.