R107/2007-DK3-2017.01
OIML CERTIFICATE OF CONFORMITY
Issuing authority
Name: DELTA
Address: Venlighedsvej 4
2970 Hørsholm
Denmark
Person responsible: J. Hovgård Jensen
Name: BAYKON Endüstriyel Kontrol Sistemleri San ve Tic A.S.
Address: Tuzla Kimya Sanayicileri OSB
Organik Caddesi 31
Tepeören, Tuzla
34956 Istanbul
TURKEY
of the certified pattern: BAYKON Endüstriyel Kontrol Sistemleri San ve Tic A.S.
Identification of the certified pattern: Discontinuous totalizing automatic weighing instrument Type: BX14 Further characteristics are set out on page 2-3
This certificate attests the conformity of the above mentioned pattern (represented by the samples identified in the associated test report) with the requirements of the following Recommendation of the International Organization of Legal Metrology (OIML):
R107
edition 2007
for accuracy class 0.2,0.5,1 or 2
This certificate relates only to the metrological and technical characteristics of the pattern of the instrument concerned, as covered by the relevant OIML International Recommendation.
This certificate does not bestow any form of legal international approval.
Page 1. This certificate includes 3 pages
OIML Certificate N° R107/2007-DK3-17.01
The conformity was established by tests described in the associated test reports from DELTA, DK, No. DANAK-1914612, dated 22-10-2014 that includes 72 pages
The issuing authority: DELTA, OIML Issuing Authority DK3 13 November 2017
J. Hovgård Jensen Certification Officer
Characteristics
| Accuracy class | X(x) | 0.2,0.5,1 or 2 |
| Weighing range | Single-interval | |
| Number of scale intervals | n | ≤10000 |
| Verification scale interval | $d_{t}=$ | ≥1g and ≥0.4μV |
| Maximum capacity | Max | n×$d_{t}$ |
| Minimum capacity | Min | ≥20% of Max |
| Minimum totalized load | $\sum_{\min}$ | according to OIML R107-1 section 2.5 |
| Subtractive tare | T | ≤-Max |
| Excitation voltage | $U_{\mathrm{exc}}$ | 5VDC |
| Load cell impedance | Min./Max. | 43ohm/1100ohm |
| Load cell connecting system | 4-wire or 6-wire, shielded | |
| Module fractional factor | $p_{i}$ | 0.5 for the indicator |
| Interface | Protective, according to paragraph 5.3.6 | |
| Connected load cells | Shall comply with R60 | |
| Supply voltage | 12-28VDC | |
| Temperature range for the indicator | -10 $^{\circ}C$/+40 $^{\circ}C$ | |
| Weighing mode | Static | |
| Electromagnetic class | E2 | |
| Humidity | Non-condensing | |
| Extra warm-up time | Not needed | |
| Software identification: | 2.xx | |
| Max cable length to junction box | 4824 m/mm^{2}$ | |
| Rate of operation | determined at initial verification |
Page 2. This certificate includes 3 pages
OIML Certificate N° R107/2007-DK3-17.01
Feeding
Gravity feeder
Screw feeder
Belt feeder
Vibratory feeder
Devices
Initial zero setting device
Semi-automatic zero setting
Zero tracking
Automatic zero setting
Semi-automatic subtractive tare
Automatic subtractive tare
Zero indicator
Indication of stable equilibrium
Net indicator
Net / Gross indication device
Gravity compensation device
Extended resolution device
Printing device
Coarse feeding device
Fine feeding device
Important note:
Apart from the mention of the certificate's reference number and the name of the OIML Member State in which the certificate was issued, partial quotation of the certificate or of the associated test report is not permitted, though they may be reproduced in full.